Cargando…
Pure oxygen ventilation during general anaesthesia does not result in increased postoperative respiratory morbidity but decreases surgical site infection. An observational clinical study
Background. Pure oxygen ventilation during anaesthesia is debatable, as it may lead to development of atelectasis. Rationale of the study was to demonstrate the harmlessness of ventilation with pure oxygen. Methods. This is a single-centre, one-department observational trial. Prospectively collected...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
PeerJ Inc.
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4194458/ https://www.ncbi.nlm.nih.gov/pubmed/25320681 http://dx.doi.org/10.7717/peerj.613 |
_version_ | 1782339120399384576 |
---|---|
author | von Bormann, Benno Suksompong, Sirilak Weiler, Jürgen Zander, Rolf |
author_facet | von Bormann, Benno Suksompong, Sirilak Weiler, Jürgen Zander, Rolf |
author_sort | von Bormann, Benno |
collection | PubMed |
description | Background. Pure oxygen ventilation during anaesthesia is debatable, as it may lead to development of atelectasis. Rationale of the study was to demonstrate the harmlessness of ventilation with pure oxygen. Methods. This is a single-centre, one-department observational trial. Prospectively collected routine-data of 76,784 patients undergoing general, gynaecological, orthopaedic, and vascular surgery during 1995–2009 were retrospectively analysed. Postoperative hypoxia, unplanned ICU-admission, surgical site infection (SSI), postoperative nausea and vomiting (PONV), and hospital mortality were continuously recorded. During 1996 the anaesthetic ventilation for all patients was changed from 30% oxygen plus 70% nitrous oxide to 100% oxygen in low-flow mode. Therefore, in order to minimize the potential of confounding due to a variety of treatments being used, we directly compared years 1995 (30% oxygen) and 1997 (100%), whereas the period 1998 to 2009 is simply described. Results. Comparing 1995 to 1997 pure oxygen ventilation led to a decreased incidence of postoperative hypoxic events (4.3 to 3.0%; p < 0.0001) and hospital mortality (2.1 to 1.6%; p = 0.088) as well as SSI (8.0 to 5.0%; p < 0.0001) and PONV (21.6 to 17.5%; p < 0.0001). There was no effect on unplanned ICU-admission (1.1 to 0.9; p = 0.18). Conclusions. The observed effects may be partly due to pure oxygen ventilation, abandonment of nitrous oxide, and application of low-flow anesthesia. Pure oxygen ventilation during general anaesthesia is harmless, as long as certain standards are adhered to. It makes anaesthesia simpler and safer and may reduce clinical morbidity, such as postoperative hypoxia and surgical site infection. |
format | Online Article Text |
id | pubmed-4194458 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | PeerJ Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-41944582014-10-15 Pure oxygen ventilation during general anaesthesia does not result in increased postoperative respiratory morbidity but decreases surgical site infection. An observational clinical study von Bormann, Benno Suksompong, Sirilak Weiler, Jürgen Zander, Rolf PeerJ Anaesthesiology and Pain Management Background. Pure oxygen ventilation during anaesthesia is debatable, as it may lead to development of atelectasis. Rationale of the study was to demonstrate the harmlessness of ventilation with pure oxygen. Methods. This is a single-centre, one-department observational trial. Prospectively collected routine-data of 76,784 patients undergoing general, gynaecological, orthopaedic, and vascular surgery during 1995–2009 were retrospectively analysed. Postoperative hypoxia, unplanned ICU-admission, surgical site infection (SSI), postoperative nausea and vomiting (PONV), and hospital mortality were continuously recorded. During 1996 the anaesthetic ventilation for all patients was changed from 30% oxygen plus 70% nitrous oxide to 100% oxygen in low-flow mode. Therefore, in order to minimize the potential of confounding due to a variety of treatments being used, we directly compared years 1995 (30% oxygen) and 1997 (100%), whereas the period 1998 to 2009 is simply described. Results. Comparing 1995 to 1997 pure oxygen ventilation led to a decreased incidence of postoperative hypoxic events (4.3 to 3.0%; p < 0.0001) and hospital mortality (2.1 to 1.6%; p = 0.088) as well as SSI (8.0 to 5.0%; p < 0.0001) and PONV (21.6 to 17.5%; p < 0.0001). There was no effect on unplanned ICU-admission (1.1 to 0.9; p = 0.18). Conclusions. The observed effects may be partly due to pure oxygen ventilation, abandonment of nitrous oxide, and application of low-flow anesthesia. Pure oxygen ventilation during general anaesthesia is harmless, as long as certain standards are adhered to. It makes anaesthesia simpler and safer and may reduce clinical morbidity, such as postoperative hypoxia and surgical site infection. PeerJ Inc. 2014-10-09 /pmc/articles/PMC4194458/ /pubmed/25320681 http://dx.doi.org/10.7717/peerj.613 Text en © 2014 von Bormann et al. http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, reproduction and adaptation in any medium and for any purpose provided that it is properly attributed. For attribution, the original author(s), title, publication source (PeerJ) and either DOI or URL of the article must be cited. |
spellingShingle | Anaesthesiology and Pain Management von Bormann, Benno Suksompong, Sirilak Weiler, Jürgen Zander, Rolf Pure oxygen ventilation during general anaesthesia does not result in increased postoperative respiratory morbidity but decreases surgical site infection. An observational clinical study |
title | Pure oxygen ventilation during general anaesthesia does not result in increased postoperative respiratory morbidity but decreases surgical site infection. An observational clinical study |
title_full | Pure oxygen ventilation during general anaesthesia does not result in increased postoperative respiratory morbidity but decreases surgical site infection. An observational clinical study |
title_fullStr | Pure oxygen ventilation during general anaesthesia does not result in increased postoperative respiratory morbidity but decreases surgical site infection. An observational clinical study |
title_full_unstemmed | Pure oxygen ventilation during general anaesthesia does not result in increased postoperative respiratory morbidity but decreases surgical site infection. An observational clinical study |
title_short | Pure oxygen ventilation during general anaesthesia does not result in increased postoperative respiratory morbidity but decreases surgical site infection. An observational clinical study |
title_sort | pure oxygen ventilation during general anaesthesia does not result in increased postoperative respiratory morbidity but decreases surgical site infection. an observational clinical study |
topic | Anaesthesiology and Pain Management |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4194458/ https://www.ncbi.nlm.nih.gov/pubmed/25320681 http://dx.doi.org/10.7717/peerj.613 |
work_keys_str_mv | AT vonbormannbenno pureoxygenventilationduringgeneralanaesthesiadoesnotresultinincreasedpostoperativerespiratorymorbiditybutdecreasessurgicalsiteinfectionanobservationalclinicalstudy AT suksompongsirilak pureoxygenventilationduringgeneralanaesthesiadoesnotresultinincreasedpostoperativerespiratorymorbiditybutdecreasessurgicalsiteinfectionanobservationalclinicalstudy AT weilerjurgen pureoxygenventilationduringgeneralanaesthesiadoesnotresultinincreasedpostoperativerespiratorymorbiditybutdecreasessurgicalsiteinfectionanobservationalclinicalstudy AT zanderrolf pureoxygenventilationduringgeneralanaesthesiadoesnotresultinincreasedpostoperativerespiratorymorbiditybutdecreasessurgicalsiteinfectionanobservationalclinicalstudy |