Cargando…

Duration of Electrically Induced Atrial Fibrillation Is Augmented by High Voltage of Stimulus with Higher Blood Pressure in Hypertensive Rats

Objective. Many previous clinical studies have suggested that atrial fibrillation (AF) is closely associated with hypertension. However, the benefits of antihypertensive therapy on AF are still inconsistent, and it is necessary to explore the factors augmenting AF in hypertensive rats. The aim of th...

Descripción completa

Detalles Bibliográficos
Autores principales: Nagayama, Tomomi, Hirooka, Yoshitaka, Chishaki, Akiko, Takemoto, Masao, Mukai, Yasushi, Inoue, Shujiro, Kishi, Takuya, Sunagawa, Kenji
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4195393/
https://www.ncbi.nlm.nih.gov/pubmed/25328683
http://dx.doi.org/10.1155/2014/980505
_version_ 1782339306647453696
author Nagayama, Tomomi
Hirooka, Yoshitaka
Chishaki, Akiko
Takemoto, Masao
Mukai, Yasushi
Inoue, Shujiro
Kishi, Takuya
Sunagawa, Kenji
author_facet Nagayama, Tomomi
Hirooka, Yoshitaka
Chishaki, Akiko
Takemoto, Masao
Mukai, Yasushi
Inoue, Shujiro
Kishi, Takuya
Sunagawa, Kenji
author_sort Nagayama, Tomomi
collection PubMed
description Objective. Many previous clinical studies have suggested that atrial fibrillation (AF) is closely associated with hypertension. However, the benefits of antihypertensive therapy on AF are still inconsistent, and it is necessary to explore the factors augmenting AF in hypertensive rats. The aim of the present study was to investigate the correlation between arterial pressure or voltage stimulus and to the duration of electrically induced AF in normotensive or hypertensive rats. Methods. AF was reproducibly induced by transesophageal atrial burst pacing in spontaneously hypertensive rats (SHR) and Wistar-Kyoto rats (WKY). We did the burst pacing at high (20 V) or low (5 V) voltage. Results. Duration of AF did not correlate with systolic blood pressure (SBP) and stimulus voltage in WKY. However, only in SHR, duration of AF with high stimulus voltage significantly correlated with SBP and was significantly longer in high than in low voltage stimulus. Discussion and Conclusion. Duration of AF is augmented by high voltage stimulus with higher blood pressure in SHR.
format Online
Article
Text
id pubmed-4195393
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-41953932014-10-19 Duration of Electrically Induced Atrial Fibrillation Is Augmented by High Voltage of Stimulus with Higher Blood Pressure in Hypertensive Rats Nagayama, Tomomi Hirooka, Yoshitaka Chishaki, Akiko Takemoto, Masao Mukai, Yasushi Inoue, Shujiro Kishi, Takuya Sunagawa, Kenji Int J Hypertens Research Article Objective. Many previous clinical studies have suggested that atrial fibrillation (AF) is closely associated with hypertension. However, the benefits of antihypertensive therapy on AF are still inconsistent, and it is necessary to explore the factors augmenting AF in hypertensive rats. The aim of the present study was to investigate the correlation between arterial pressure or voltage stimulus and to the duration of electrically induced AF in normotensive or hypertensive rats. Methods. AF was reproducibly induced by transesophageal atrial burst pacing in spontaneously hypertensive rats (SHR) and Wistar-Kyoto rats (WKY). We did the burst pacing at high (20 V) or low (5 V) voltage. Results. Duration of AF did not correlate with systolic blood pressure (SBP) and stimulus voltage in WKY. However, only in SHR, duration of AF with high stimulus voltage significantly correlated with SBP and was significantly longer in high than in low voltage stimulus. Discussion and Conclusion. Duration of AF is augmented by high voltage stimulus with higher blood pressure in SHR. Hindawi Publishing Corporation 2014 2014-09-25 /pmc/articles/PMC4195393/ /pubmed/25328683 http://dx.doi.org/10.1155/2014/980505 Text en Copyright © 2014 Tomomi Nagayama et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Nagayama, Tomomi
Hirooka, Yoshitaka
Chishaki, Akiko
Takemoto, Masao
Mukai, Yasushi
Inoue, Shujiro
Kishi, Takuya
Sunagawa, Kenji
Duration of Electrically Induced Atrial Fibrillation Is Augmented by High Voltage of Stimulus with Higher Blood Pressure in Hypertensive Rats
title Duration of Electrically Induced Atrial Fibrillation Is Augmented by High Voltage of Stimulus with Higher Blood Pressure in Hypertensive Rats
title_full Duration of Electrically Induced Atrial Fibrillation Is Augmented by High Voltage of Stimulus with Higher Blood Pressure in Hypertensive Rats
title_fullStr Duration of Electrically Induced Atrial Fibrillation Is Augmented by High Voltage of Stimulus with Higher Blood Pressure in Hypertensive Rats
title_full_unstemmed Duration of Electrically Induced Atrial Fibrillation Is Augmented by High Voltage of Stimulus with Higher Blood Pressure in Hypertensive Rats
title_short Duration of Electrically Induced Atrial Fibrillation Is Augmented by High Voltage of Stimulus with Higher Blood Pressure in Hypertensive Rats
title_sort duration of electrically induced atrial fibrillation is augmented by high voltage of stimulus with higher blood pressure in hypertensive rats
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4195393/
https://www.ncbi.nlm.nih.gov/pubmed/25328683
http://dx.doi.org/10.1155/2014/980505
work_keys_str_mv AT nagayamatomomi durationofelectricallyinducedatrialfibrillationisaugmentedbyhighvoltageofstimuluswithhigherbloodpressureinhypertensiverats
AT hirookayoshitaka durationofelectricallyinducedatrialfibrillationisaugmentedbyhighvoltageofstimuluswithhigherbloodpressureinhypertensiverats
AT chishakiakiko durationofelectricallyinducedatrialfibrillationisaugmentedbyhighvoltageofstimuluswithhigherbloodpressureinhypertensiverats
AT takemotomasao durationofelectricallyinducedatrialfibrillationisaugmentedbyhighvoltageofstimuluswithhigherbloodpressureinhypertensiverats
AT mukaiyasushi durationofelectricallyinducedatrialfibrillationisaugmentedbyhighvoltageofstimuluswithhigherbloodpressureinhypertensiverats
AT inoueshujiro durationofelectricallyinducedatrialfibrillationisaugmentedbyhighvoltageofstimuluswithhigherbloodpressureinhypertensiverats
AT kishitakuya durationofelectricallyinducedatrialfibrillationisaugmentedbyhighvoltageofstimuluswithhigherbloodpressureinhypertensiverats
AT sunagawakenji durationofelectricallyinducedatrialfibrillationisaugmentedbyhighvoltageofstimuluswithhigherbloodpressureinhypertensiverats