Cargando…

Clinical and biomechanical evaluation of three bioscaffold augmentation devices used for superficial digital flexor tenorrhaphy in donkeys (Equus asinus): An experimental study

The present study was designed to carry out an in vivo and in vitro comparative evaluation of three bio-scaffold augmentation devices used for superficial digital flexor tenorrhaphy in donkeys. Twenty-four clinically healthy donkeys were assigned for three treatment trials (n = 8) using one of three...

Descripción completa

Detalles Bibliográficos
Autores principales: El-Shafaey, El-Sayed A., Karrouf, Gamal I., Zaghloul, Adel E.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4195463/
https://www.ncbi.nlm.nih.gov/pubmed/25685407
http://dx.doi.org/10.1016/j.jare.2012.02.001
_version_ 1782339315899039744
author El-Shafaey, El-Sayed A.
Karrouf, Gamal I.
Zaghloul, Adel E.
author_facet El-Shafaey, El-Sayed A.
Karrouf, Gamal I.
Zaghloul, Adel E.
author_sort El-Shafaey, El-Sayed A.
collection PubMed
description The present study was designed to carry out an in vivo and in vitro comparative evaluation of three bio-scaffold augmentation devices used for superficial digital flexor tenorrhaphy in donkeys. Twenty-four clinically healthy donkeys were assigned for three treatment trials (n = 8) using one of three bioscaffold materials (glycerolized bovine pericardium xenograft, tendon allograft and allograft with glycerolized by bovine pericardium). In addition, eight clinically healthy donkeys were selected to serve as control. Clinical signs of each animal were scored and the sum of all clinical indexes was calculated at each time point of the experiment. Four donkeys from each group were euthanized at 45 and 90 days postoperatively, respectively, for biomechanical and histopathological evaluation of treated superficial digital flexor tendon (SDFT). The failure stress in allograft shielding group significantly increased compared to the corresponding values of the other groups at 45 (62.7 ± 6.5 N mm(−2)) and 90 (88.8 ± 3.5 N mm(−2)) days postoperatively. The fetlock angle in the allograft shielding group at both 45 (112.8° ± 4.4) and 90 (123.8° ± 1.1) days postoperatively showed a significant increase (p < 0.05) relative to the values of the other groups and a significant decrease (p < 0.05) when compared to normal angle (125° ± 0). However, the histomorphological findings revealed no remarkable changes between the treatment groups. In conclusion, the failure stress, fetlock angle and histomorphological findings may provide useful information about the healing characteristics of SDFT tenorrhaphy. The bio-scaffold augmentation devices, either xenogenic or allogenic, provide good alternative techniques accelerating SDFT healing with minimal adhesions in donkeys.
format Online
Article
Text
id pubmed-4195463
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-41954632015-02-14 Clinical and biomechanical evaluation of three bioscaffold augmentation devices used for superficial digital flexor tenorrhaphy in donkeys (Equus asinus): An experimental study El-Shafaey, El-Sayed A. Karrouf, Gamal I. Zaghloul, Adel E. J Adv Res Original Article The present study was designed to carry out an in vivo and in vitro comparative evaluation of three bio-scaffold augmentation devices used for superficial digital flexor tenorrhaphy in donkeys. Twenty-four clinically healthy donkeys were assigned for three treatment trials (n = 8) using one of three bioscaffold materials (glycerolized bovine pericardium xenograft, tendon allograft and allograft with glycerolized by bovine pericardium). In addition, eight clinically healthy donkeys were selected to serve as control. Clinical signs of each animal were scored and the sum of all clinical indexes was calculated at each time point of the experiment. Four donkeys from each group were euthanized at 45 and 90 days postoperatively, respectively, for biomechanical and histopathological evaluation of treated superficial digital flexor tendon (SDFT). The failure stress in allograft shielding group significantly increased compared to the corresponding values of the other groups at 45 (62.7 ± 6.5 N mm(−2)) and 90 (88.8 ± 3.5 N mm(−2)) days postoperatively. The fetlock angle in the allograft shielding group at both 45 (112.8° ± 4.4) and 90 (123.8° ± 1.1) days postoperatively showed a significant increase (p < 0.05) relative to the values of the other groups and a significant decrease (p < 0.05) when compared to normal angle (125° ± 0). However, the histomorphological findings revealed no remarkable changes between the treatment groups. In conclusion, the failure stress, fetlock angle and histomorphological findings may provide useful information about the healing characteristics of SDFT tenorrhaphy. The bio-scaffold augmentation devices, either xenogenic or allogenic, provide good alternative techniques accelerating SDFT healing with minimal adhesions in donkeys. Elsevier 2013-01 2012-04-09 /pmc/articles/PMC4195463/ /pubmed/25685407 http://dx.doi.org/10.1016/j.jare.2012.02.001 Text en © 2012 Cairo University. Production and hosting by Elsevier B.V. All rights reserved. http://creativecommons.org/licenses/by-nc-nd/3.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/3.0/).
spellingShingle Original Article
El-Shafaey, El-Sayed A.
Karrouf, Gamal I.
Zaghloul, Adel E.
Clinical and biomechanical evaluation of three bioscaffold augmentation devices used for superficial digital flexor tenorrhaphy in donkeys (Equus asinus): An experimental study
title Clinical and biomechanical evaluation of three bioscaffold augmentation devices used for superficial digital flexor tenorrhaphy in donkeys (Equus asinus): An experimental study
title_full Clinical and biomechanical evaluation of three bioscaffold augmentation devices used for superficial digital flexor tenorrhaphy in donkeys (Equus asinus): An experimental study
title_fullStr Clinical and biomechanical evaluation of three bioscaffold augmentation devices used for superficial digital flexor tenorrhaphy in donkeys (Equus asinus): An experimental study
title_full_unstemmed Clinical and biomechanical evaluation of three bioscaffold augmentation devices used for superficial digital flexor tenorrhaphy in donkeys (Equus asinus): An experimental study
title_short Clinical and biomechanical evaluation of three bioscaffold augmentation devices used for superficial digital flexor tenorrhaphy in donkeys (Equus asinus): An experimental study
title_sort clinical and biomechanical evaluation of three bioscaffold augmentation devices used for superficial digital flexor tenorrhaphy in donkeys (equus asinus): an experimental study
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4195463/
https://www.ncbi.nlm.nih.gov/pubmed/25685407
http://dx.doi.org/10.1016/j.jare.2012.02.001
work_keys_str_mv AT elshafaeyelsayeda clinicalandbiomechanicalevaluationofthreebioscaffoldaugmentationdevicesusedforsuperficialdigitalflexortenorrhaphyindonkeysequusasinusanexperimentalstudy
AT karroufgamali clinicalandbiomechanicalevaluationofthreebioscaffoldaugmentationdevicesusedforsuperficialdigitalflexortenorrhaphyindonkeysequusasinusanexperimentalstudy
AT zaghlouladele clinicalandbiomechanicalevaluationofthreebioscaffoldaugmentationdevicesusedforsuperficialdigitalflexortenorrhaphyindonkeysequusasinusanexperimentalstudy