Cargando…
The Diagnostic Value and Accuracy of Conjunctival Impression Cytology, Dry Eye Symptomatology, and Routine Tear Function Tests in Computer Users
AIMS AND OBJECTIVES: To compare the diagnostic value and accuracy of dry eye scoring system (DESS), conjunctival impression cytology (CIC), tear film breakup time (TBUT), and Schirmer's test in computer users. METHODS: A case–control study was done at two referral eye centers. Eyes of 344 compu...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Medknow Publications & Media Pvt Ltd
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4196356/ https://www.ncbi.nlm.nih.gov/pubmed/25328335 http://dx.doi.org/10.4103/0974-2727.141507 |
_version_ | 1782339468163809280 |
---|---|
author | Bhargava, Rahul Kumar, Prachi Kaur, Avinash Kumar, Manjushri Mishra, Anurag |
author_facet | Bhargava, Rahul Kumar, Prachi Kaur, Avinash Kumar, Manjushri Mishra, Anurag |
author_sort | Bhargava, Rahul |
collection | PubMed |
description | AIMS AND OBJECTIVES: To compare the diagnostic value and accuracy of dry eye scoring system (DESS), conjunctival impression cytology (CIC), tear film breakup time (TBUT), and Schirmer's test in computer users. METHODS: A case–control study was done at two referral eye centers. Eyes of 344 computer users were compared to 371 eyes of age and sex matched controls. Dry eye questionnaire (DESS) was administered to both groups and they further underwent measurement of TBUT, Schirmer's, and CIC. Correlation analysis was performed between DESS, CIC, TBUT, and Schirmer's test scores. A Pearson's coefficient of the linear expression (R(2)) of 0.5 or more was statistically significant. RESULTS: The mean age in cases (26.05 ± 4.06 years) was comparable to controls (25.67 ± 3.65 years) (P = 0.465). The mean symptom score in computer users was significantly higher as compared to controls (P < 0.001). Mean TBUT, Schirmer's test values, and goblet cell density were significantly reduced in computer users (P < 0.001). TBUT, Schirmer's, and CIC were abnormal in 48.5%, 29.1%, and 38.4% symptomatic computer users respectively as compared to 8%, 6.7%, and 7.3% symptomatic controls respectively. On correlation analysis, there was a significant (inverse) association of dry eye symptoms (DESS) with TBUT and CIC scores (R(2) > 0.5), in contrast to Schirmer's scores (R(2) < 0.5). Duration of computer usage had a significant effect on dry eye symptoms severity, TBUT, and CIC scores as compared to Schirmer's test. CONCLUSION: DESS should be used in combination with TBUT and CIC for dry eye evaluation in computer users. |
format | Online Article Text |
id | pubmed-4196356 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | Medknow Publications & Media Pvt Ltd |
record_format | MEDLINE/PubMed |
spelling | pubmed-41963562014-10-17 The Diagnostic Value and Accuracy of Conjunctival Impression Cytology, Dry Eye Symptomatology, and Routine Tear Function Tests in Computer Users Bhargava, Rahul Kumar, Prachi Kaur, Avinash Kumar, Manjushri Mishra, Anurag J Lab Physicians Original Article AIMS AND OBJECTIVES: To compare the diagnostic value and accuracy of dry eye scoring system (DESS), conjunctival impression cytology (CIC), tear film breakup time (TBUT), and Schirmer's test in computer users. METHODS: A case–control study was done at two referral eye centers. Eyes of 344 computer users were compared to 371 eyes of age and sex matched controls. Dry eye questionnaire (DESS) was administered to both groups and they further underwent measurement of TBUT, Schirmer's, and CIC. Correlation analysis was performed between DESS, CIC, TBUT, and Schirmer's test scores. A Pearson's coefficient of the linear expression (R(2)) of 0.5 or more was statistically significant. RESULTS: The mean age in cases (26.05 ± 4.06 years) was comparable to controls (25.67 ± 3.65 years) (P = 0.465). The mean symptom score in computer users was significantly higher as compared to controls (P < 0.001). Mean TBUT, Schirmer's test values, and goblet cell density were significantly reduced in computer users (P < 0.001). TBUT, Schirmer's, and CIC were abnormal in 48.5%, 29.1%, and 38.4% symptomatic computer users respectively as compared to 8%, 6.7%, and 7.3% symptomatic controls respectively. On correlation analysis, there was a significant (inverse) association of dry eye symptoms (DESS) with TBUT and CIC scores (R(2) > 0.5), in contrast to Schirmer's scores (R(2) < 0.5). Duration of computer usage had a significant effect on dry eye symptoms severity, TBUT, and CIC scores as compared to Schirmer's test. CONCLUSION: DESS should be used in combination with TBUT and CIC for dry eye evaluation in computer users. Medknow Publications & Media Pvt Ltd 2014 /pmc/articles/PMC4196356/ /pubmed/25328335 http://dx.doi.org/10.4103/0974-2727.141507 Text en Copyright: © Journal of Laboratory Physicians http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Bhargava, Rahul Kumar, Prachi Kaur, Avinash Kumar, Manjushri Mishra, Anurag The Diagnostic Value and Accuracy of Conjunctival Impression Cytology, Dry Eye Symptomatology, and Routine Tear Function Tests in Computer Users |
title | The Diagnostic Value and Accuracy of Conjunctival Impression Cytology, Dry Eye Symptomatology, and Routine Tear Function Tests in Computer Users |
title_full | The Diagnostic Value and Accuracy of Conjunctival Impression Cytology, Dry Eye Symptomatology, and Routine Tear Function Tests in Computer Users |
title_fullStr | The Diagnostic Value and Accuracy of Conjunctival Impression Cytology, Dry Eye Symptomatology, and Routine Tear Function Tests in Computer Users |
title_full_unstemmed | The Diagnostic Value and Accuracy of Conjunctival Impression Cytology, Dry Eye Symptomatology, and Routine Tear Function Tests in Computer Users |
title_short | The Diagnostic Value and Accuracy of Conjunctival Impression Cytology, Dry Eye Symptomatology, and Routine Tear Function Tests in Computer Users |
title_sort | diagnostic value and accuracy of conjunctival impression cytology, dry eye symptomatology, and routine tear function tests in computer users |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4196356/ https://www.ncbi.nlm.nih.gov/pubmed/25328335 http://dx.doi.org/10.4103/0974-2727.141507 |
work_keys_str_mv | AT bhargavarahul thediagnosticvalueandaccuracyofconjunctivalimpressioncytologydryeyesymptomatologyandroutinetearfunctiontestsincomputerusers AT kumarprachi thediagnosticvalueandaccuracyofconjunctivalimpressioncytologydryeyesymptomatologyandroutinetearfunctiontestsincomputerusers AT kauravinash thediagnosticvalueandaccuracyofconjunctivalimpressioncytologydryeyesymptomatologyandroutinetearfunctiontestsincomputerusers AT kumarmanjushri thediagnosticvalueandaccuracyofconjunctivalimpressioncytologydryeyesymptomatologyandroutinetearfunctiontestsincomputerusers AT mishraanurag thediagnosticvalueandaccuracyofconjunctivalimpressioncytologydryeyesymptomatologyandroutinetearfunctiontestsincomputerusers AT bhargavarahul diagnosticvalueandaccuracyofconjunctivalimpressioncytologydryeyesymptomatologyandroutinetearfunctiontestsincomputerusers AT kumarprachi diagnosticvalueandaccuracyofconjunctivalimpressioncytologydryeyesymptomatologyandroutinetearfunctiontestsincomputerusers AT kauravinash diagnosticvalueandaccuracyofconjunctivalimpressioncytologydryeyesymptomatologyandroutinetearfunctiontestsincomputerusers AT kumarmanjushri diagnosticvalueandaccuracyofconjunctivalimpressioncytologydryeyesymptomatologyandroutinetearfunctiontestsincomputerusers AT mishraanurag diagnosticvalueandaccuracyofconjunctivalimpressioncytologydryeyesymptomatologyandroutinetearfunctiontestsincomputerusers |