Cargando…

Anatomic Variations of Cervical and High Thoracic Ligamentum Flavum

BACKGROUND: Epidural blocks are widely used for the management of acute and chronic pain. The technique of loss of resistance is frequently adopted to determine the epidural space. A discontinuity of the ligamentum flavum may increase the risk of failure to identify the epidural space. The purpose o...

Descripción completa

Detalles Bibliográficos
Autores principales: Yoon, Sang Pil, Kim, Hyun Jung, Choi, Yun Suk
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Pain Society 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4196496/
https://www.ncbi.nlm.nih.gov/pubmed/25317280
http://dx.doi.org/10.3344/kjp.2014.27.4.321
_version_ 1782339485788274688
author Yoon, Sang Pil
Kim, Hyun Jung
Choi, Yun Suk
author_facet Yoon, Sang Pil
Kim, Hyun Jung
Choi, Yun Suk
author_sort Yoon, Sang Pil
collection PubMed
description BACKGROUND: Epidural blocks are widely used for the management of acute and chronic pain. The technique of loss of resistance is frequently adopted to determine the epidural space. A discontinuity of the ligamentum flavum may increase the risk of failure to identify the epidural space. The purpose of this study was to investigate the anatomic variations of the cervical and high thoracic ligamentum flavum in embalmed cadavers. METHODS: Vertebral column specimens of 15 human cadavers were obtained. After vertebral arches were detached from pedicles, the dural sac and epidural connective tissue were removed. The ligamentum flavum from C3 to T6 was directly examined anteriorly. RESULTS: The incidence of midline gaps in the ligamentum flavum was 87%-100% between C3 and T2. The incidence decreased below this level and was the lowest at T4-T5 (8%). Among the levels with a gap, the location of a gap in the caudal third of the ligamentum flavum was more frequent than in the middle or cephalic portion of the ligamentum flavum. CONCLUSIONS: The cervical and high thoracic ligamentum flavum frequently has midline intervals with various features, especially in the caudal portion of the intervertebral space. Therefore, the ligamentum flavum is not always reliable as a perceptible barrier to identify the epidural space at these vertebral levels. Additionally, it may be more useful to insert the needle into the cephalic portion of the intervertebral space than in the caudal portion.
format Online
Article
Text
id pubmed-4196496
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher The Korean Pain Society
record_format MEDLINE/PubMed
spelling pubmed-41964962014-10-14 Anatomic Variations of Cervical and High Thoracic Ligamentum Flavum Yoon, Sang Pil Kim, Hyun Jung Choi, Yun Suk Korean J Pain Original Article BACKGROUND: Epidural blocks are widely used for the management of acute and chronic pain. The technique of loss of resistance is frequently adopted to determine the epidural space. A discontinuity of the ligamentum flavum may increase the risk of failure to identify the epidural space. The purpose of this study was to investigate the anatomic variations of the cervical and high thoracic ligamentum flavum in embalmed cadavers. METHODS: Vertebral column specimens of 15 human cadavers were obtained. After vertebral arches were detached from pedicles, the dural sac and epidural connective tissue were removed. The ligamentum flavum from C3 to T6 was directly examined anteriorly. RESULTS: The incidence of midline gaps in the ligamentum flavum was 87%-100% between C3 and T2. The incidence decreased below this level and was the lowest at T4-T5 (8%). Among the levels with a gap, the location of a gap in the caudal third of the ligamentum flavum was more frequent than in the middle or cephalic portion of the ligamentum flavum. CONCLUSIONS: The cervical and high thoracic ligamentum flavum frequently has midline intervals with various features, especially in the caudal portion of the intervertebral space. Therefore, the ligamentum flavum is not always reliable as a perceptible barrier to identify the epidural space at these vertebral levels. Additionally, it may be more useful to insert the needle into the cephalic portion of the intervertebral space than in the caudal portion. The Korean Pain Society 2014-10 2014-10-01 /pmc/articles/PMC4196496/ /pubmed/25317280 http://dx.doi.org/10.3344/kjp.2014.27.4.321 Text en Copyright © The Korean Pain Society, 2014 http://creativecommons.org/licenses/by-nc/3.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/), which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Yoon, Sang Pil
Kim, Hyun Jung
Choi, Yun Suk
Anatomic Variations of Cervical and High Thoracic Ligamentum Flavum
title Anatomic Variations of Cervical and High Thoracic Ligamentum Flavum
title_full Anatomic Variations of Cervical and High Thoracic Ligamentum Flavum
title_fullStr Anatomic Variations of Cervical and High Thoracic Ligamentum Flavum
title_full_unstemmed Anatomic Variations of Cervical and High Thoracic Ligamentum Flavum
title_short Anatomic Variations of Cervical and High Thoracic Ligamentum Flavum
title_sort anatomic variations of cervical and high thoracic ligamentum flavum
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4196496/
https://www.ncbi.nlm.nih.gov/pubmed/25317280
http://dx.doi.org/10.3344/kjp.2014.27.4.321
work_keys_str_mv AT yoonsangpil anatomicvariationsofcervicalandhighthoracicligamentumflavum
AT kimhyunjung anatomicvariationsofcervicalandhighthoracicligamentumflavum
AT choiyunsuk anatomicvariationsofcervicalandhighthoracicligamentumflavum