Two new types of assays to determine protein concentrations in biological fluids using mass spectrometry of intact proteins with cystatin C in spinal fluid as an example

There is no reference method that is generally acknowledged to be unbiased for the determination of the concentration of any protein in biological fluids. This is probably because mass spectrometry (MS) methods acknowledged as reference methods for determination of low molecular mass substances in b...

Descripción completa

Detalles Bibliográficos
Autores principales: Tyrefors, Niklas, Michelsen, Peter, Grubb, Anders
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Informa Healthcare 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4196591/
https://www.ncbi.nlm.nih.gov/pubmed/25010448
http://dx.doi.org/10.3109/00365513.2014.917697
_version_ 1782339505029644288
author Tyrefors, Niklas
Michelsen, Peter
Grubb, Anders
author_facet Tyrefors, Niklas
Michelsen, Peter
Grubb, Anders
author_sort Tyrefors, Niklas
collection PubMed
description There is no reference method that is generally acknowledged to be unbiased for the determination of the concentration of any protein in biological fluids. This is probably because mass spectrometry (MS) methods acknowledged as reference methods for determination of low molecular mass substances in biological fluids, e.g. creatinine, have been difficult to adapt for proteins. Here we suggest two tentative MS methods, which might be used as reference methods for the determination of protein concentrations in biological fluids. One is based upon the addition to the fluid of a non-proteome reference protein, very similar to the one to be measured, and analyzing the ratio between the corresponding peaks in a selected ion monitoring (SIM) chromatogram. We call this method LC-MS-NPRP (NPRP, Non-Proteome Reference Protein). The other method is based upon the classical standard addition assay for low molecular mass substances. The results of these assays for cystatin C in spinal fluid were compared to those obtained by an immunoassay. Both methods indicated lower concentration than the immunoassay. This was found to be due to the presence of a significant fraction of monohydroxylated cystatin C in spinal fluid. It turned out that the sum of the unhydroxylated and hydroxylated cystatin C concentrations, determined by either of the two MS methods, were close to the results obtained by the immunoassay. These MS-based methods analyze intact proteins and therefore seem more suitable for the determination of protein concentrations in biological fluids than other MS-based methods requiring proteolytic degradation with its inherent lack of precision.
format Online
Article
Text
id pubmed-4196591
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Informa Healthcare
record_format MEDLINE/PubMed
spelling pubmed-41965912014-10-27 Two new types of assays to determine protein concentrations in biological fluids using mass spectrometry of intact proteins with cystatin C in spinal fluid as an example Tyrefors, Niklas Michelsen, Peter Grubb, Anders Scand J Clin Lab Invest Original Article There is no reference method that is generally acknowledged to be unbiased for the determination of the concentration of any protein in biological fluids. This is probably because mass spectrometry (MS) methods acknowledged as reference methods for determination of low molecular mass substances in biological fluids, e.g. creatinine, have been difficult to adapt for proteins. Here we suggest two tentative MS methods, which might be used as reference methods for the determination of protein concentrations in biological fluids. One is based upon the addition to the fluid of a non-proteome reference protein, very similar to the one to be measured, and analyzing the ratio between the corresponding peaks in a selected ion monitoring (SIM) chromatogram. We call this method LC-MS-NPRP (NPRP, Non-Proteome Reference Protein). The other method is based upon the classical standard addition assay for low molecular mass substances. The results of these assays for cystatin C in spinal fluid were compared to those obtained by an immunoassay. Both methods indicated lower concentration than the immunoassay. This was found to be due to the presence of a significant fraction of monohydroxylated cystatin C in spinal fluid. It turned out that the sum of the unhydroxylated and hydroxylated cystatin C concentrations, determined by either of the two MS methods, were close to the results obtained by the immunoassay. These MS-based methods analyze intact proteins and therefore seem more suitable for the determination of protein concentrations in biological fluids than other MS-based methods requiring proteolytic degradation with its inherent lack of precision. Informa Healthcare 2014-09 2014-07-10 /pmc/articles/PMC4196591/ /pubmed/25010448 http://dx.doi.org/10.3109/00365513.2014.917697 Text en © 2014 Informa Healthcare http://creativecommons.org/licenses/by-nc-nd/3.0/ This is an open-access article distributed under the terms of the CC-BY-NC-ND 3.0 License which permits users to download and share the article for non-commercial purposes, so long as the article is reproduced in the whole without changes, and provided the original source is credited.
spellingShingle Original Article
Tyrefors, Niklas
Michelsen, Peter
Grubb, Anders
Two new types of assays to determine protein concentrations in biological fluids using mass spectrometry of intact proteins with cystatin C in spinal fluid as an example
title Two new types of assays to determine protein concentrations in biological fluids using mass spectrometry of intact proteins with cystatin C in spinal fluid as an example
title_full Two new types of assays to determine protein concentrations in biological fluids using mass spectrometry of intact proteins with cystatin C in spinal fluid as an example
title_fullStr Two new types of assays to determine protein concentrations in biological fluids using mass spectrometry of intact proteins with cystatin C in spinal fluid as an example
title_full_unstemmed Two new types of assays to determine protein concentrations in biological fluids using mass spectrometry of intact proteins with cystatin C in spinal fluid as an example
title_short Two new types of assays to determine protein concentrations in biological fluids using mass spectrometry of intact proteins with cystatin C in spinal fluid as an example
title_sort two new types of assays to determine protein concentrations in biological fluids using mass spectrometry of intact proteins with cystatin c in spinal fluid as an example
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4196591/
https://www.ncbi.nlm.nih.gov/pubmed/25010448
http://dx.doi.org/10.3109/00365513.2014.917697
work_keys_str_mv AT tyreforsniklas twonewtypesofassaystodetermineproteinconcentrationsinbiologicalfluidsusingmassspectrometryofintactproteinswithcystatincinspinalfluidasanexample
AT michelsenpeter twonewtypesofassaystodetermineproteinconcentrationsinbiologicalfluidsusingmassspectrometryofintactproteinswithcystatincinspinalfluidasanexample
AT grubbanders twonewtypesofassaystodetermineproteinconcentrationsinbiologicalfluidsusingmassspectrometryofintactproteinswithcystatincinspinalfluidasanexample