Cargando…
A Stabilization Device That Promotes the Efficiency of Cardiopulmonary Resuscitation during Ambulance Transportation to the Level as under Non-Moving Conditions
BACKGROUND: The survival rate of patients with out-of-hospital cardiac arrest is low, and measures to improve the quality of cardiopulmonary resuscitation (CPR) during ambulance transportation are desirable. We designed a stabilization device, and in a randomized crossover trial we found performing...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4198082/ https://www.ncbi.nlm.nih.gov/pubmed/25329643 http://dx.doi.org/10.1371/journal.pone.0107960 |
_version_ | 1782339687057195008 |
---|---|
author | Foo, Ning-Ping Chang, Jer-Hao Su, Shih-Bin Chen, Kow-Tong Cheng, Ching-Fa Chen, Pei-Chung Lin, Tsung-Yi Guo, How-Ran |
author_facet | Foo, Ning-Ping Chang, Jer-Hao Su, Shih-Bin Chen, Kow-Tong Cheng, Ching-Fa Chen, Pei-Chung Lin, Tsung-Yi Guo, How-Ran |
author_sort | Foo, Ning-Ping |
collection | PubMed |
description | BACKGROUND: The survival rate of patients with out-of-hospital cardiac arrest is low, and measures to improve the quality of cardiopulmonary resuscitation (CPR) during ambulance transportation are desirable. We designed a stabilization device, and in a randomized crossover trial we found performing CPR in a moving ambulance with the device (MD) could achieve better efficiency than that without the device (MND), but the efficiency was lower than that in a non-moving ambulance (NM). PURPOSE: To evaluate whether a modified version of the stabilization device, can promote further the quality of CPR during ambulance transportation. METHODS: Participants of the previous study were recruited, and they performed CPR for 10 minutes in a moving ambulance with the modified version of the stabilization device (MVSD). The primary outcomes were effective chest compressions and no-flow fraction recorded by a skill-reporter manikin. The secondary outcomes included back pain, physiological parameters, and the participants' rating about the device after performing CPR. RESULTS: The overall effective compressions in 10 minutes were 86.4±17.5% for NM, 60.9±14.6% for MND, 69.7±22.4% for MD, and 86.6%±13.2% for MVSD (p<0.001). Whereas changes in back pain severity and physiology parameters were similar under all conditions, MVSD had the lowest no-flow fraction. Differences in effective compressions and the no-flow fraction between MVSD and NM did not reach statistical significance. CONCLUSIONS: The use of the modified device can improve quality of CPR in a moving ambulance to a level similar to that in a non-moving condition without increasing the severity of back pain. |
format | Online Article Text |
id | pubmed-4198082 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-41980822014-10-21 A Stabilization Device That Promotes the Efficiency of Cardiopulmonary Resuscitation during Ambulance Transportation to the Level as under Non-Moving Conditions Foo, Ning-Ping Chang, Jer-Hao Su, Shih-Bin Chen, Kow-Tong Cheng, Ching-Fa Chen, Pei-Chung Lin, Tsung-Yi Guo, How-Ran PLoS One Research Article BACKGROUND: The survival rate of patients with out-of-hospital cardiac arrest is low, and measures to improve the quality of cardiopulmonary resuscitation (CPR) during ambulance transportation are desirable. We designed a stabilization device, and in a randomized crossover trial we found performing CPR in a moving ambulance with the device (MD) could achieve better efficiency than that without the device (MND), but the efficiency was lower than that in a non-moving ambulance (NM). PURPOSE: To evaluate whether a modified version of the stabilization device, can promote further the quality of CPR during ambulance transportation. METHODS: Participants of the previous study were recruited, and they performed CPR for 10 minutes in a moving ambulance with the modified version of the stabilization device (MVSD). The primary outcomes were effective chest compressions and no-flow fraction recorded by a skill-reporter manikin. The secondary outcomes included back pain, physiological parameters, and the participants' rating about the device after performing CPR. RESULTS: The overall effective compressions in 10 minutes were 86.4±17.5% for NM, 60.9±14.6% for MND, 69.7±22.4% for MD, and 86.6%±13.2% for MVSD (p<0.001). Whereas changes in back pain severity and physiology parameters were similar under all conditions, MVSD had the lowest no-flow fraction. Differences in effective compressions and the no-flow fraction between MVSD and NM did not reach statistical significance. CONCLUSIONS: The use of the modified device can improve quality of CPR in a moving ambulance to a level similar to that in a non-moving condition without increasing the severity of back pain. Public Library of Science 2014-10-15 /pmc/articles/PMC4198082/ /pubmed/25329643 http://dx.doi.org/10.1371/journal.pone.0107960 Text en © 2014 Foo et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited. |
spellingShingle | Research Article Foo, Ning-Ping Chang, Jer-Hao Su, Shih-Bin Chen, Kow-Tong Cheng, Ching-Fa Chen, Pei-Chung Lin, Tsung-Yi Guo, How-Ran A Stabilization Device That Promotes the Efficiency of Cardiopulmonary Resuscitation during Ambulance Transportation to the Level as under Non-Moving Conditions |
title | A Stabilization Device That Promotes the Efficiency of Cardiopulmonary Resuscitation during Ambulance Transportation to the Level as under Non-Moving Conditions |
title_full | A Stabilization Device That Promotes the Efficiency of Cardiopulmonary Resuscitation during Ambulance Transportation to the Level as under Non-Moving Conditions |
title_fullStr | A Stabilization Device That Promotes the Efficiency of Cardiopulmonary Resuscitation during Ambulance Transportation to the Level as under Non-Moving Conditions |
title_full_unstemmed | A Stabilization Device That Promotes the Efficiency of Cardiopulmonary Resuscitation during Ambulance Transportation to the Level as under Non-Moving Conditions |
title_short | A Stabilization Device That Promotes the Efficiency of Cardiopulmonary Resuscitation during Ambulance Transportation to the Level as under Non-Moving Conditions |
title_sort | stabilization device that promotes the efficiency of cardiopulmonary resuscitation during ambulance transportation to the level as under non-moving conditions |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4198082/ https://www.ncbi.nlm.nih.gov/pubmed/25329643 http://dx.doi.org/10.1371/journal.pone.0107960 |
work_keys_str_mv | AT fooningping astabilizationdevicethatpromotestheefficiencyofcardiopulmonaryresuscitationduringambulancetransportationtothelevelasundernonmovingconditions AT changjerhao astabilizationdevicethatpromotestheefficiencyofcardiopulmonaryresuscitationduringambulancetransportationtothelevelasundernonmovingconditions AT sushihbin astabilizationdevicethatpromotestheefficiencyofcardiopulmonaryresuscitationduringambulancetransportationtothelevelasundernonmovingconditions AT chenkowtong astabilizationdevicethatpromotestheefficiencyofcardiopulmonaryresuscitationduringambulancetransportationtothelevelasundernonmovingconditions AT chengchingfa astabilizationdevicethatpromotestheefficiencyofcardiopulmonaryresuscitationduringambulancetransportationtothelevelasundernonmovingconditions AT chenpeichung astabilizationdevicethatpromotestheefficiencyofcardiopulmonaryresuscitationduringambulancetransportationtothelevelasundernonmovingconditions AT lintsungyi astabilizationdevicethatpromotestheefficiencyofcardiopulmonaryresuscitationduringambulancetransportationtothelevelasundernonmovingconditions AT guohowran astabilizationdevicethatpromotestheefficiencyofcardiopulmonaryresuscitationduringambulancetransportationtothelevelasundernonmovingconditions AT fooningping stabilizationdevicethatpromotestheefficiencyofcardiopulmonaryresuscitationduringambulancetransportationtothelevelasundernonmovingconditions AT changjerhao stabilizationdevicethatpromotestheefficiencyofcardiopulmonaryresuscitationduringambulancetransportationtothelevelasundernonmovingconditions AT sushihbin stabilizationdevicethatpromotestheefficiencyofcardiopulmonaryresuscitationduringambulancetransportationtothelevelasundernonmovingconditions AT chenkowtong stabilizationdevicethatpromotestheefficiencyofcardiopulmonaryresuscitationduringambulancetransportationtothelevelasundernonmovingconditions AT chengchingfa stabilizationdevicethatpromotestheefficiencyofcardiopulmonaryresuscitationduringambulancetransportationtothelevelasundernonmovingconditions AT chenpeichung stabilizationdevicethatpromotestheefficiencyofcardiopulmonaryresuscitationduringambulancetransportationtothelevelasundernonmovingconditions AT lintsungyi stabilizationdevicethatpromotestheefficiencyofcardiopulmonaryresuscitationduringambulancetransportationtothelevelasundernonmovingconditions AT guohowran stabilizationdevicethatpromotestheefficiencyofcardiopulmonaryresuscitationduringambulancetransportationtothelevelasundernonmovingconditions |