A Stabilization Device That Promotes the Efficiency of Cardiopulmonary Resuscitation during Ambulance Transportation to the Level as under Non-Moving Conditions

BACKGROUND: The survival rate of patients with out-of-hospital cardiac arrest is low, and measures to improve the quality of cardiopulmonary resuscitation (CPR) during ambulance transportation are desirable. We designed a stabilization device, and in a randomized crossover trial we found performing...

Descripción completa

Detalles Bibliográficos
Autores principales: Foo, Ning-Ping, Chang, Jer-Hao, Su, Shih-Bin, Chen, Kow-Tong, Cheng, Ching-Fa, Chen, Pei-Chung, Lin, Tsung-Yi, Guo, How-Ran
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4198082/
https://www.ncbi.nlm.nih.gov/pubmed/25329643
http://dx.doi.org/10.1371/journal.pone.0107960
_version_ 1782339687057195008
author Foo, Ning-Ping
Chang, Jer-Hao
Su, Shih-Bin
Chen, Kow-Tong
Cheng, Ching-Fa
Chen, Pei-Chung
Lin, Tsung-Yi
Guo, How-Ran
author_facet Foo, Ning-Ping
Chang, Jer-Hao
Su, Shih-Bin
Chen, Kow-Tong
Cheng, Ching-Fa
Chen, Pei-Chung
Lin, Tsung-Yi
Guo, How-Ran
author_sort Foo, Ning-Ping
collection PubMed
description BACKGROUND: The survival rate of patients with out-of-hospital cardiac arrest is low, and measures to improve the quality of cardiopulmonary resuscitation (CPR) during ambulance transportation are desirable. We designed a stabilization device, and in a randomized crossover trial we found performing CPR in a moving ambulance with the device (MD) could achieve better efficiency than that without the device (MND), but the efficiency was lower than that in a non-moving ambulance (NM). PURPOSE: To evaluate whether a modified version of the stabilization device, can promote further the quality of CPR during ambulance transportation. METHODS: Participants of the previous study were recruited, and they performed CPR for 10 minutes in a moving ambulance with the modified version of the stabilization device (MVSD). The primary outcomes were effective chest compressions and no-flow fraction recorded by a skill-reporter manikin. The secondary outcomes included back pain, physiological parameters, and the participants' rating about the device after performing CPR. RESULTS: The overall effective compressions in 10 minutes were 86.4±17.5% for NM, 60.9±14.6% for MND, 69.7±22.4% for MD, and 86.6%±13.2% for MVSD (p<0.001). Whereas changes in back pain severity and physiology parameters were similar under all conditions, MVSD had the lowest no-flow fraction. Differences in effective compressions and the no-flow fraction between MVSD and NM did not reach statistical significance. CONCLUSIONS: The use of the modified device can improve quality of CPR in a moving ambulance to a level similar to that in a non-moving condition without increasing the severity of back pain.
format Online
Article
Text
id pubmed-4198082
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-41980822014-10-21 A Stabilization Device That Promotes the Efficiency of Cardiopulmonary Resuscitation during Ambulance Transportation to the Level as under Non-Moving Conditions Foo, Ning-Ping Chang, Jer-Hao Su, Shih-Bin Chen, Kow-Tong Cheng, Ching-Fa Chen, Pei-Chung Lin, Tsung-Yi Guo, How-Ran PLoS One Research Article BACKGROUND: The survival rate of patients with out-of-hospital cardiac arrest is low, and measures to improve the quality of cardiopulmonary resuscitation (CPR) during ambulance transportation are desirable. We designed a stabilization device, and in a randomized crossover trial we found performing CPR in a moving ambulance with the device (MD) could achieve better efficiency than that without the device (MND), but the efficiency was lower than that in a non-moving ambulance (NM). PURPOSE: To evaluate whether a modified version of the stabilization device, can promote further the quality of CPR during ambulance transportation. METHODS: Participants of the previous study were recruited, and they performed CPR for 10 minutes in a moving ambulance with the modified version of the stabilization device (MVSD). The primary outcomes were effective chest compressions and no-flow fraction recorded by a skill-reporter manikin. The secondary outcomes included back pain, physiological parameters, and the participants' rating about the device after performing CPR. RESULTS: The overall effective compressions in 10 minutes were 86.4±17.5% for NM, 60.9±14.6% for MND, 69.7±22.4% for MD, and 86.6%±13.2% for MVSD (p<0.001). Whereas changes in back pain severity and physiology parameters were similar under all conditions, MVSD had the lowest no-flow fraction. Differences in effective compressions and the no-flow fraction between MVSD and NM did not reach statistical significance. CONCLUSIONS: The use of the modified device can improve quality of CPR in a moving ambulance to a level similar to that in a non-moving condition without increasing the severity of back pain. Public Library of Science 2014-10-15 /pmc/articles/PMC4198082/ /pubmed/25329643 http://dx.doi.org/10.1371/journal.pone.0107960 Text en © 2014 Foo et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited.
spellingShingle Research Article
Foo, Ning-Ping
Chang, Jer-Hao
Su, Shih-Bin
Chen, Kow-Tong
Cheng, Ching-Fa
Chen, Pei-Chung
Lin, Tsung-Yi
Guo, How-Ran
A Stabilization Device That Promotes the Efficiency of Cardiopulmonary Resuscitation during Ambulance Transportation to the Level as under Non-Moving Conditions
title A Stabilization Device That Promotes the Efficiency of Cardiopulmonary Resuscitation during Ambulance Transportation to the Level as under Non-Moving Conditions
title_full A Stabilization Device That Promotes the Efficiency of Cardiopulmonary Resuscitation during Ambulance Transportation to the Level as under Non-Moving Conditions
title_fullStr A Stabilization Device That Promotes the Efficiency of Cardiopulmonary Resuscitation during Ambulance Transportation to the Level as under Non-Moving Conditions
title_full_unstemmed A Stabilization Device That Promotes the Efficiency of Cardiopulmonary Resuscitation during Ambulance Transportation to the Level as under Non-Moving Conditions
title_short A Stabilization Device That Promotes the Efficiency of Cardiopulmonary Resuscitation during Ambulance Transportation to the Level as under Non-Moving Conditions
title_sort stabilization device that promotes the efficiency of cardiopulmonary resuscitation during ambulance transportation to the level as under non-moving conditions
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4198082/
https://www.ncbi.nlm.nih.gov/pubmed/25329643
http://dx.doi.org/10.1371/journal.pone.0107960
work_keys_str_mv AT fooningping astabilizationdevicethatpromotestheefficiencyofcardiopulmonaryresuscitationduringambulancetransportationtothelevelasundernonmovingconditions
AT changjerhao astabilizationdevicethatpromotestheefficiencyofcardiopulmonaryresuscitationduringambulancetransportationtothelevelasundernonmovingconditions
AT sushihbin astabilizationdevicethatpromotestheefficiencyofcardiopulmonaryresuscitationduringambulancetransportationtothelevelasundernonmovingconditions
AT chenkowtong astabilizationdevicethatpromotestheefficiencyofcardiopulmonaryresuscitationduringambulancetransportationtothelevelasundernonmovingconditions
AT chengchingfa astabilizationdevicethatpromotestheefficiencyofcardiopulmonaryresuscitationduringambulancetransportationtothelevelasundernonmovingconditions
AT chenpeichung astabilizationdevicethatpromotestheefficiencyofcardiopulmonaryresuscitationduringambulancetransportationtothelevelasundernonmovingconditions
AT lintsungyi astabilizationdevicethatpromotestheefficiencyofcardiopulmonaryresuscitationduringambulancetransportationtothelevelasundernonmovingconditions
AT guohowran astabilizationdevicethatpromotestheefficiencyofcardiopulmonaryresuscitationduringambulancetransportationtothelevelasundernonmovingconditions
AT fooningping stabilizationdevicethatpromotestheefficiencyofcardiopulmonaryresuscitationduringambulancetransportationtothelevelasundernonmovingconditions
AT changjerhao stabilizationdevicethatpromotestheefficiencyofcardiopulmonaryresuscitationduringambulancetransportationtothelevelasundernonmovingconditions
AT sushihbin stabilizationdevicethatpromotestheefficiencyofcardiopulmonaryresuscitationduringambulancetransportationtothelevelasundernonmovingconditions
AT chenkowtong stabilizationdevicethatpromotestheefficiencyofcardiopulmonaryresuscitationduringambulancetransportationtothelevelasundernonmovingconditions
AT chengchingfa stabilizationdevicethatpromotestheefficiencyofcardiopulmonaryresuscitationduringambulancetransportationtothelevelasundernonmovingconditions
AT chenpeichung stabilizationdevicethatpromotestheefficiencyofcardiopulmonaryresuscitationduringambulancetransportationtothelevelasundernonmovingconditions
AT lintsungyi stabilizationdevicethatpromotestheefficiencyofcardiopulmonaryresuscitationduringambulancetransportationtothelevelasundernonmovingconditions
AT guohowran stabilizationdevicethatpromotestheefficiencyofcardiopulmonaryresuscitationduringambulancetransportationtothelevelasundernonmovingconditions