Monitoring of the Environment at the Transplant Unit—Hemato-Oncology Clinic
Aims: Aim of this study was to monitor the environment at the Transplant Unit—Hemato-Oncology Clinic, University Hospital Olomouc (Olomouc, Czech Republic) and identify risks for the patients. Methods and Results: Microorganisms were cultivated under standard aerobic conditions. Strains were biochem...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4199030/ https://www.ncbi.nlm.nih.gov/pubmed/25222472 http://dx.doi.org/10.3390/ijerph110909480 |
_version_ | 1782339842224422912 |
---|---|
author | Matoušková, Ivanka Holy, Ondřej |
author_facet | Matoušková, Ivanka Holy, Ondřej |
author_sort | Matoušková, Ivanka |
collection | PubMed |
description | Aims: Aim of this study was to monitor the environment at the Transplant Unit—Hemato-Oncology Clinic, University Hospital Olomouc (Olomouc, Czech Republic) and identify risks for the patients. Methods and Results: Microorganisms were cultivated under standard aerobic conditions. Strains were biochemically identified using the BD Phoenix™ PID Panel (USA). Legionella pneumophila was identified by DNA sequencing. From the air, the most frequently isolated strains were coagulase-negative staphylococci (94.3%), Micrococcus spp. and Bacillus spp. No Gram-negative strains were isolated from the air. From the surfaces, the most frequently isolated Gram-positive strains were coagulase-negative staphylococci (67.4%), Bacillus spp., enterococci (5.5%), Staphylococcus aureus (2.3%) and Micrococcus spp. (1.7%). From the surfaces, the most frequently isolated Gram-negative strains were from genera Pseudomonas (28%), Enterobacter (28%), E. coli (6%), and Klebsiella spp. (5%). From the personnel, the most frequently isolated Gram-positive strains were coagulase-negative staphylococci (59.6%), Bacillus spp. (24.1%) and Staphylococcus aureus (9.8%). From the personnel, the most frequently isolated Gram-negative strains were Enterobacter spp. (61%), Klebsiella oxytoca (18%), and E. coli (11%). Microscopic filamentous fungi were isolated in 13 cases (2.71%). Isolated strains were Aspergillus spp. (4), Trichoderma spp. (2), Penicillium spp. (2), one case of the strains Paecilomyces spp., Eurotium spp., Monilia spp. Conclusions: The study found no significant deviations in the microbial contamination of the cleanroom air. The personnel entrance of the Transplant Unit represent a high risk area, an extreme value (7270 CFU/m(3)) was recorded. Regime measures are fully effective, no other deficiencies were found. Significance and Impact of the Study: This epidemiological study, which was held for the duration of one year at the Transplant Unit—Hemato-Oncology Clinic, University Hospital Olomouc. The study monitored microbial contamination of the cleanroom air, surfaces, water, colonization of the personnel by bacterial strains of epidemiological consequence. |
format | Online Article Text |
id | pubmed-4199030 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-41990302014-10-17 Monitoring of the Environment at the Transplant Unit—Hemato-Oncology Clinic Matoušková, Ivanka Holy, Ondřej Int J Environ Res Public Health Article Aims: Aim of this study was to monitor the environment at the Transplant Unit—Hemato-Oncology Clinic, University Hospital Olomouc (Olomouc, Czech Republic) and identify risks for the patients. Methods and Results: Microorganisms were cultivated under standard aerobic conditions. Strains were biochemically identified using the BD Phoenix™ PID Panel (USA). Legionella pneumophila was identified by DNA sequencing. From the air, the most frequently isolated strains were coagulase-negative staphylococci (94.3%), Micrococcus spp. and Bacillus spp. No Gram-negative strains were isolated from the air. From the surfaces, the most frequently isolated Gram-positive strains were coagulase-negative staphylococci (67.4%), Bacillus spp., enterococci (5.5%), Staphylococcus aureus (2.3%) and Micrococcus spp. (1.7%). From the surfaces, the most frequently isolated Gram-negative strains were from genera Pseudomonas (28%), Enterobacter (28%), E. coli (6%), and Klebsiella spp. (5%). From the personnel, the most frequently isolated Gram-positive strains were coagulase-negative staphylococci (59.6%), Bacillus spp. (24.1%) and Staphylococcus aureus (9.8%). From the personnel, the most frequently isolated Gram-negative strains were Enterobacter spp. (61%), Klebsiella oxytoca (18%), and E. coli (11%). Microscopic filamentous fungi were isolated in 13 cases (2.71%). Isolated strains were Aspergillus spp. (4), Trichoderma spp. (2), Penicillium spp. (2), one case of the strains Paecilomyces spp., Eurotium spp., Monilia spp. Conclusions: The study found no significant deviations in the microbial contamination of the cleanroom air. The personnel entrance of the Transplant Unit represent a high risk area, an extreme value (7270 CFU/m(3)) was recorded. Regime measures are fully effective, no other deficiencies were found. Significance and Impact of the Study: This epidemiological study, which was held for the duration of one year at the Transplant Unit—Hemato-Oncology Clinic, University Hospital Olomouc. The study monitored microbial contamination of the cleanroom air, surfaces, water, colonization of the personnel by bacterial strains of epidemiological consequence. MDPI 2014-09-12 2014-09 /pmc/articles/PMC4199030/ /pubmed/25222472 http://dx.doi.org/10.3390/ijerph110909480 Text en © 2014 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/3.0/). |
spellingShingle | Article Matoušková, Ivanka Holy, Ondřej Monitoring of the Environment at the Transplant Unit—Hemato-Oncology Clinic |
title | Monitoring of the Environment at the Transplant Unit—Hemato-Oncology Clinic |
title_full | Monitoring of the Environment at the Transplant Unit—Hemato-Oncology Clinic |
title_fullStr | Monitoring of the Environment at the Transplant Unit—Hemato-Oncology Clinic |
title_full_unstemmed | Monitoring of the Environment at the Transplant Unit—Hemato-Oncology Clinic |
title_short | Monitoring of the Environment at the Transplant Unit—Hemato-Oncology Clinic |
title_sort | monitoring of the environment at the transplant unit—hemato-oncology clinic |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4199030/ https://www.ncbi.nlm.nih.gov/pubmed/25222472 http://dx.doi.org/10.3390/ijerph110909480 |
work_keys_str_mv | AT matouskovaivanka monitoringoftheenvironmentatthetransplantunithematooncologyclinic AT holyondrej monitoringoftheenvironmentatthetransplantunithematooncologyclinic |