Cargando…

Treatment envelope evaluation in transcranial magnetic resonance-guided focused ultrasound utilizing 3D MR thermometry

BACKGROUND: Current clinical targets for transcranial magnetic resonance-guided focused ultrasound (tcMRgFUS) are all located close to the geometric center of the skull convexity, which minimizes challenges related to focusing the ultrasound through the skull bone. Non-central targets will have to b...

Descripción completa

Detalles Bibliográficos
Autores principales: Odéen, Henrik, de Bever, Joshua, Almquist, Scott, Farrer, Alexis, Todd, Nick, Payne, Allison, Snell, John W, Christensen, Douglas A, Parker, Dennis L
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4199783/
https://www.ncbi.nlm.nih.gov/pubmed/25343028
http://dx.doi.org/10.1186/2050-5736-2-19
_version_ 1782339976238727168
author Odéen, Henrik
de Bever, Joshua
Almquist, Scott
Farrer, Alexis
Todd, Nick
Payne, Allison
Snell, John W
Christensen, Douglas A
Parker, Dennis L
author_facet Odéen, Henrik
de Bever, Joshua
Almquist, Scott
Farrer, Alexis
Todd, Nick
Payne, Allison
Snell, John W
Christensen, Douglas A
Parker, Dennis L
author_sort Odéen, Henrik
collection PubMed
description BACKGROUND: Current clinical targets for transcranial magnetic resonance-guided focused ultrasound (tcMRgFUS) are all located close to the geometric center of the skull convexity, which minimizes challenges related to focusing the ultrasound through the skull bone. Non-central targets will have to be reached to treat a wider variety of neurological disorders and solid tumors. Treatment envelope studies utilizing two-dimensional (2D) magnetic resonance (MR) thermometry have previously been performed to determine the regions in which therapeutic levels of FUS can currently be delivered. Since 2D MR thermometry was used, very limited information about unintended heating in near-field tissue/bone interfaces could be deduced. METHODS: In this paper, we present a proof-of-concept treatment envelope study with three-dimensional (3D) MR thermometry monitoring of FUS heatings performed in a phantom and a lamb model. While the moderate-sized transducer used was not designed for transcranial geometries, the 3D temperature maps enable monitoring of the entire sonication field of view, including both the focal spot and near-field tissue/bone interfaces, for full characterization of all heating that may occur. 3D MR thermometry is achieved by a combination of k-space subsampling and a previously described temporally constrained reconstruction method. RESULTS: We present two different types of treatment envelopes. The first is based only on the focal spot heating—the type that can be derived from 2D MR thermometry. The second type is based on the relative near-field heating and is calculated as the ratio between the focal spot heating and the near-field heating. This utilizes the full 3D MR thermometry data achieved in this study. CONCLUSIONS: It is shown that 3D MR thermometry can be used to improve the safety assessment in treatment envelope evaluations. Using a non-optimal transducer, it is shown that some regions where therapeutic levels of FUS can be delivered, as suggested by the first type of envelope, are not necessarily safely treated due to the amount of unintended near-field heating occurring. The results presented in this study highlight the need for 3D MR thermometry in tcMRgFUS.
format Online
Article
Text
id pubmed-4199783
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-41997832014-10-23 Treatment envelope evaluation in transcranial magnetic resonance-guided focused ultrasound utilizing 3D MR thermometry Odéen, Henrik de Bever, Joshua Almquist, Scott Farrer, Alexis Todd, Nick Payne, Allison Snell, John W Christensen, Douglas A Parker, Dennis L J Ther Ultrasound Research BACKGROUND: Current clinical targets for transcranial magnetic resonance-guided focused ultrasound (tcMRgFUS) are all located close to the geometric center of the skull convexity, which minimizes challenges related to focusing the ultrasound through the skull bone. Non-central targets will have to be reached to treat a wider variety of neurological disorders and solid tumors. Treatment envelope studies utilizing two-dimensional (2D) magnetic resonance (MR) thermometry have previously been performed to determine the regions in which therapeutic levels of FUS can currently be delivered. Since 2D MR thermometry was used, very limited information about unintended heating in near-field tissue/bone interfaces could be deduced. METHODS: In this paper, we present a proof-of-concept treatment envelope study with three-dimensional (3D) MR thermometry monitoring of FUS heatings performed in a phantom and a lamb model. While the moderate-sized transducer used was not designed for transcranial geometries, the 3D temperature maps enable monitoring of the entire sonication field of view, including both the focal spot and near-field tissue/bone interfaces, for full characterization of all heating that may occur. 3D MR thermometry is achieved by a combination of k-space subsampling and a previously described temporally constrained reconstruction method. RESULTS: We present two different types of treatment envelopes. The first is based only on the focal spot heating—the type that can be derived from 2D MR thermometry. The second type is based on the relative near-field heating and is calculated as the ratio between the focal spot heating and the near-field heating. This utilizes the full 3D MR thermometry data achieved in this study. CONCLUSIONS: It is shown that 3D MR thermometry can be used to improve the safety assessment in treatment envelope evaluations. Using a non-optimal transducer, it is shown that some regions where therapeutic levels of FUS can be delivered, as suggested by the first type of envelope, are not necessarily safely treated due to the amount of unintended near-field heating occurring. The results presented in this study highlight the need for 3D MR thermometry in tcMRgFUS. BioMed Central 2014-10-16 /pmc/articles/PMC4199783/ /pubmed/25343028 http://dx.doi.org/10.1186/2050-5736-2-19 Text en Copyright © 2014 Odéen et al.; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/4.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research
Odéen, Henrik
de Bever, Joshua
Almquist, Scott
Farrer, Alexis
Todd, Nick
Payne, Allison
Snell, John W
Christensen, Douglas A
Parker, Dennis L
Treatment envelope evaluation in transcranial magnetic resonance-guided focused ultrasound utilizing 3D MR thermometry
title Treatment envelope evaluation in transcranial magnetic resonance-guided focused ultrasound utilizing 3D MR thermometry
title_full Treatment envelope evaluation in transcranial magnetic resonance-guided focused ultrasound utilizing 3D MR thermometry
title_fullStr Treatment envelope evaluation in transcranial magnetic resonance-guided focused ultrasound utilizing 3D MR thermometry
title_full_unstemmed Treatment envelope evaluation in transcranial magnetic resonance-guided focused ultrasound utilizing 3D MR thermometry
title_short Treatment envelope evaluation in transcranial magnetic resonance-guided focused ultrasound utilizing 3D MR thermometry
title_sort treatment envelope evaluation in transcranial magnetic resonance-guided focused ultrasound utilizing 3d mr thermometry
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4199783/
https://www.ncbi.nlm.nih.gov/pubmed/25343028
http://dx.doi.org/10.1186/2050-5736-2-19
work_keys_str_mv AT odeenhenrik treatmentenvelopeevaluationintranscranialmagneticresonanceguidedfocusedultrasoundutilizing3dmrthermometry
AT debeverjoshua treatmentenvelopeevaluationintranscranialmagneticresonanceguidedfocusedultrasoundutilizing3dmrthermometry
AT almquistscott treatmentenvelopeevaluationintranscranialmagneticresonanceguidedfocusedultrasoundutilizing3dmrthermometry
AT farreralexis treatmentenvelopeevaluationintranscranialmagneticresonanceguidedfocusedultrasoundutilizing3dmrthermometry
AT toddnick treatmentenvelopeevaluationintranscranialmagneticresonanceguidedfocusedultrasoundutilizing3dmrthermometry
AT payneallison treatmentenvelopeevaluationintranscranialmagneticresonanceguidedfocusedultrasoundutilizing3dmrthermometry
AT snelljohnw treatmentenvelopeevaluationintranscranialmagneticresonanceguidedfocusedultrasoundutilizing3dmrthermometry
AT christensendouglasa treatmentenvelopeevaluationintranscranialmagneticresonanceguidedfocusedultrasoundutilizing3dmrthermometry
AT parkerdennisl treatmentenvelopeevaluationintranscranialmagneticresonanceguidedfocusedultrasoundutilizing3dmrthermometry