Cargando…
Reamed intramedullary exchange nailing: treatment of choice of aseptic femoral shaft nonunion
BACKGROUND: The aim of this study was to evaluate a standardized method of treatment of femoral nonunion of the isthmal femur excluding non-united metaphyseal fractures. METHODS: Between 2003 and 2010, 72 consecutive patients with nonunion of the femoral shaft were operated using a standardized prot...
Autores principales: | Hierholzer, Christian, Glowalla, Claudio, Herrler, Michael, von Rüden, Christian, Hungerer, Sven, Bühren, Volker, Friederichs, Jan |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4201668/ https://www.ncbi.nlm.nih.gov/pubmed/25300373 http://dx.doi.org/10.1186/s13018-014-0088-1 |
Ejemplares similares
-
Long-term outcome following additional rhBMP-7 application in revision surgery of aseptic humeral, femoral, and tibial shaft nonunion
por: Hackl, Simon, et al.
Publicado: (2017) -
Results of revision intramedullary nailing with and without auxillary plate in aseptic trochanteric and subtrochanteric nonunion
por: Dietze, Christina, et al.
Publicado: (2021) -
Plate Augmentation in Aseptic Femoral Shaft Nonunion after Intramedullary Nailing: A Literature Review
por: Perisano, Carlo, et al.
Publicado: (2022) -
Clinical Outcome of Ream Versus Unream Intramedullary Nailing for Femoral Shaft Fractures
por: Bagheri, Farshid, et al.
Publicado: (2013) -
Is open bone graft always necessary when treating aseptic subtrochanteric nonunion with a reamed intramedullary nail?
por: Shin, Won Chul, et al.
Publicado: (2021)