Feasibility study of stereotactic body radiotherapy for peripheral lung tumors with a maximum dose of 100 Gy in five fractions and a heterogeneous dose distribution in the planning target volume
We evaluated toxicity and outcomes for patients with peripheral lung tumors treated with stereotactic body radiation therapy (SBRT) in a dose-escalation and dose-convergence study. A total of 15 patients were enrolled. SBRT was performed with 60 Gy in 5 fractions (fr.) prescribed to the 60% isodose...
Autores principales: | Takeda, Atsuya, Oku, Yohei, Sanuki, Naoko, Eriguchi, Takahisa, Aoki, Yousuke, Enomoto, Tatsuji, Kaneko, Takeshi, Nishimura, Shuichi, Kunieda, Etsuo |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Oxford University Press
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4202295/ https://www.ncbi.nlm.nih.gov/pubmed/24833770 http://dx.doi.org/10.1093/jrr/rru037 |
Ejemplares similares
-
Stereotactic body radiotherapy for patients with non-small-cell lung cancer using RapidArc delivery and a steep dose gradient: prescription of 60% isodose line of maximum dose fitting to the planning target volume
por: Tsurugai, Yuichiro, et al.
Publicado: (2019) -
Stereotactic body radiotherapy for patients with oligometastases from colorectal cancer: risk-adapted dose prescription with a maximum dose of 83–100 Gy in five fractions
por: Takeda, Atsuya, et al.
Publicado: (2016) -
Stereotactic body radiotherapy for chronic obstructive pulmonary disease patients undergoing or eligible for long-term domiciliary oxygen therapy
por: Hara, Yu, et al.
Publicado: (2016) -
Stereotactic body radiotherapy for T3 and T4N0M0 non–small cell lung cancer
por: Eriguchi, Takahisa, et al.
Publicado: (2016) -
Applying Artificial Neural Networks to Develop a Decision Support Tool for Tis–4N0M0 Non–Small-Cell Lung Cancer Treated With Stereotactic Body Radiotherapy
por: Nemoto, Takafumi, et al.
Publicado: (2022)