Cargando…

Test-retest reliability of temporal and spatial gait characteristics measured with an instrumented walkway system (GAITRite(®))

BACKGROUND: The purpose of this study was to determine the test-retest reliability of temporal and spatial gait measurements over a one-week period as measured using an instrumented walkway system (GAITRite(®)). METHODS: Subjects were tested on two occasions one week apart. Measurements were made at...

Descripción completa

Detalles Bibliográficos
Autores principales: van Uden, Cornelis JT, Besser, Marcus P
Formato: Texto
Lenguaje:English
Publicado: BioMed Central 2004
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC420245/
https://www.ncbi.nlm.nih.gov/pubmed/15147583
http://dx.doi.org/10.1186/1471-2474-5-13
_version_ 1782121470346919936
author van Uden, Cornelis JT
Besser, Marcus P
author_facet van Uden, Cornelis JT
Besser, Marcus P
author_sort van Uden, Cornelis JT
collection PubMed
description BACKGROUND: The purpose of this study was to determine the test-retest reliability of temporal and spatial gait measurements over a one-week period as measured using an instrumented walkway system (GAITRite(®)). METHODS: Subjects were tested on two occasions one week apart. Measurements were made at preferred and fast walking speeds using the GAITRite(® )system. Measurements tested included walking speed, step length, stride length, base of support, step time, stride time, swing time, stance time, single and double support times, and toe in-toe out angle. RESULTS: Twenty-one healthy subjects participated in this study. The group consisted of 12 men and 9 women, with an average age of 34 years (range: 19 – 59 years). At preferred walking speed, all gait measurements had ICC's of 0.92 and higher, except base of support which had an ICC of 0.80. At fast walking speed all gait measurements had ICC's above 0.89 except base of support (ICC = 0.79), CONCLUSIONS: Spatial-temporal gait measurements demonstrate good to excellent test-retest reliability over a one-week time span.
format Text
id pubmed-420245
institution National Center for Biotechnology Information
language English
publishDate 2004
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-4202452004-06-06 Test-retest reliability of temporal and spatial gait characteristics measured with an instrumented walkway system (GAITRite(®)) van Uden, Cornelis JT Besser, Marcus P BMC Musculoskelet Disord Research Article BACKGROUND: The purpose of this study was to determine the test-retest reliability of temporal and spatial gait measurements over a one-week period as measured using an instrumented walkway system (GAITRite(®)). METHODS: Subjects were tested on two occasions one week apart. Measurements were made at preferred and fast walking speeds using the GAITRite(® )system. Measurements tested included walking speed, step length, stride length, base of support, step time, stride time, swing time, stance time, single and double support times, and toe in-toe out angle. RESULTS: Twenty-one healthy subjects participated in this study. The group consisted of 12 men and 9 women, with an average age of 34 years (range: 19 – 59 years). At preferred walking speed, all gait measurements had ICC's of 0.92 and higher, except base of support which had an ICC of 0.80. At fast walking speed all gait measurements had ICC's above 0.89 except base of support (ICC = 0.79), CONCLUSIONS: Spatial-temporal gait measurements demonstrate good to excellent test-retest reliability over a one-week time span. BioMed Central 2004-05-17 /pmc/articles/PMC420245/ /pubmed/15147583 http://dx.doi.org/10.1186/1471-2474-5-13 Text en Copyright © 2004 van Uden and Besser; licensee BioMed Central Ltd. This is an Open Access article: verbatim copying and redistribution of this article are permitted in all media for any purpose, provided this notice is preserved along with the article's original URL.
spellingShingle Research Article
van Uden, Cornelis JT
Besser, Marcus P
Test-retest reliability of temporal and spatial gait characteristics measured with an instrumented walkway system (GAITRite(®))
title Test-retest reliability of temporal and spatial gait characteristics measured with an instrumented walkway system (GAITRite(®))
title_full Test-retest reliability of temporal and spatial gait characteristics measured with an instrumented walkway system (GAITRite(®))
title_fullStr Test-retest reliability of temporal and spatial gait characteristics measured with an instrumented walkway system (GAITRite(®))
title_full_unstemmed Test-retest reliability of temporal and spatial gait characteristics measured with an instrumented walkway system (GAITRite(®))
title_short Test-retest reliability of temporal and spatial gait characteristics measured with an instrumented walkway system (GAITRite(®))
title_sort test-retest reliability of temporal and spatial gait characteristics measured with an instrumented walkway system (gaitrite(®))
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC420245/
https://www.ncbi.nlm.nih.gov/pubmed/15147583
http://dx.doi.org/10.1186/1471-2474-5-13
work_keys_str_mv AT vanudencornelisjt testretestreliabilityoftemporalandspatialgaitcharacteristicsmeasuredwithaninstrumentedwalkwaysystemgaitrite
AT bessermarcusp testretestreliabilityoftemporalandspatialgaitcharacteristicsmeasuredwithaninstrumentedwalkwaysystemgaitrite