Cargando…
Test-retest reliability of temporal and spatial gait characteristics measured with an instrumented walkway system (GAITRite(®))
BACKGROUND: The purpose of this study was to determine the test-retest reliability of temporal and spatial gait measurements over a one-week period as measured using an instrumented walkway system (GAITRite(®)). METHODS: Subjects were tested on two occasions one week apart. Measurements were made at...
Autores principales: | , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2004
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC420245/ https://www.ncbi.nlm.nih.gov/pubmed/15147583 http://dx.doi.org/10.1186/1471-2474-5-13 |
_version_ | 1782121470346919936 |
---|---|
author | van Uden, Cornelis JT Besser, Marcus P |
author_facet | van Uden, Cornelis JT Besser, Marcus P |
author_sort | van Uden, Cornelis JT |
collection | PubMed |
description | BACKGROUND: The purpose of this study was to determine the test-retest reliability of temporal and spatial gait measurements over a one-week period as measured using an instrumented walkway system (GAITRite(®)). METHODS: Subjects were tested on two occasions one week apart. Measurements were made at preferred and fast walking speeds using the GAITRite(® )system. Measurements tested included walking speed, step length, stride length, base of support, step time, stride time, swing time, stance time, single and double support times, and toe in-toe out angle. RESULTS: Twenty-one healthy subjects participated in this study. The group consisted of 12 men and 9 women, with an average age of 34 years (range: 19 – 59 years). At preferred walking speed, all gait measurements had ICC's of 0.92 and higher, except base of support which had an ICC of 0.80. At fast walking speed all gait measurements had ICC's above 0.89 except base of support (ICC = 0.79), CONCLUSIONS: Spatial-temporal gait measurements demonstrate good to excellent test-retest reliability over a one-week time span. |
format | Text |
id | pubmed-420245 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2004 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-4202452004-06-06 Test-retest reliability of temporal and spatial gait characteristics measured with an instrumented walkway system (GAITRite(®)) van Uden, Cornelis JT Besser, Marcus P BMC Musculoskelet Disord Research Article BACKGROUND: The purpose of this study was to determine the test-retest reliability of temporal and spatial gait measurements over a one-week period as measured using an instrumented walkway system (GAITRite(®)). METHODS: Subjects were tested on two occasions one week apart. Measurements were made at preferred and fast walking speeds using the GAITRite(® )system. Measurements tested included walking speed, step length, stride length, base of support, step time, stride time, swing time, stance time, single and double support times, and toe in-toe out angle. RESULTS: Twenty-one healthy subjects participated in this study. The group consisted of 12 men and 9 women, with an average age of 34 years (range: 19 – 59 years). At preferred walking speed, all gait measurements had ICC's of 0.92 and higher, except base of support which had an ICC of 0.80. At fast walking speed all gait measurements had ICC's above 0.89 except base of support (ICC = 0.79), CONCLUSIONS: Spatial-temporal gait measurements demonstrate good to excellent test-retest reliability over a one-week time span. BioMed Central 2004-05-17 /pmc/articles/PMC420245/ /pubmed/15147583 http://dx.doi.org/10.1186/1471-2474-5-13 Text en Copyright © 2004 van Uden and Besser; licensee BioMed Central Ltd. This is an Open Access article: verbatim copying and redistribution of this article are permitted in all media for any purpose, provided this notice is preserved along with the article's original URL. |
spellingShingle | Research Article van Uden, Cornelis JT Besser, Marcus P Test-retest reliability of temporal and spatial gait characteristics measured with an instrumented walkway system (GAITRite(®)) |
title | Test-retest reliability of temporal and spatial gait characteristics measured with an instrumented walkway system (GAITRite(®)) |
title_full | Test-retest reliability of temporal and spatial gait characteristics measured with an instrumented walkway system (GAITRite(®)) |
title_fullStr | Test-retest reliability of temporal and spatial gait characteristics measured with an instrumented walkway system (GAITRite(®)) |
title_full_unstemmed | Test-retest reliability of temporal and spatial gait characteristics measured with an instrumented walkway system (GAITRite(®)) |
title_short | Test-retest reliability of temporal and spatial gait characteristics measured with an instrumented walkway system (GAITRite(®)) |
title_sort | test-retest reliability of temporal and spatial gait characteristics measured with an instrumented walkway system (gaitrite(®)) |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC420245/ https://www.ncbi.nlm.nih.gov/pubmed/15147583 http://dx.doi.org/10.1186/1471-2474-5-13 |
work_keys_str_mv | AT vanudencornelisjt testretestreliabilityoftemporalandspatialgaitcharacteristicsmeasuredwithaninstrumentedwalkwaysystemgaitrite AT bessermarcusp testretestreliabilityoftemporalandspatialgaitcharacteristicsmeasuredwithaninstrumentedwalkwaysystemgaitrite |