Cargando…

Prior Low- or High-Intensity Exercise Alters Pacing Strategy, Energy System Contribution and Performance during a 4-km Cycling Time Trial

We analyzed the influence of prior exercise designed to reduce predominantly muscle glycogen in either type I or II fibers on pacing and performance during a 4-km cycling time trial (TT). After preliminary and familiarization trials, in a randomized, repeated-measures crossover design, ten amateur c...

Descripción completa

Detalles Bibliográficos
Autores principales: Correia-Oliveira, Carlos Rafaell, Santos, Ralmony Alcantara, Silva-Cavalcante, Marcos David, Bertuzzi, Romulo, Kiss, Maria Augusta Peduti Dal’Molin, Bishop, David John, Lima-Silva, Adriano Eduardo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4203780/
https://www.ncbi.nlm.nih.gov/pubmed/25330452
http://dx.doi.org/10.1371/journal.pone.0110320
_version_ 1782340430448295936
author Correia-Oliveira, Carlos Rafaell
Santos, Ralmony Alcantara
Silva-Cavalcante, Marcos David
Bertuzzi, Romulo
Kiss, Maria Augusta Peduti Dal’Molin
Bishop, David John
Lima-Silva, Adriano Eduardo
author_facet Correia-Oliveira, Carlos Rafaell
Santos, Ralmony Alcantara
Silva-Cavalcante, Marcos David
Bertuzzi, Romulo
Kiss, Maria Augusta Peduti Dal’Molin
Bishop, David John
Lima-Silva, Adriano Eduardo
author_sort Correia-Oliveira, Carlos Rafaell
collection PubMed
description We analyzed the influence of prior exercise designed to reduce predominantly muscle glycogen in either type I or II fibers on pacing and performance during a 4-km cycling time trial (TT). After preliminary and familiarization trials, in a randomized, repeated-measures crossover design, ten amateur cyclists performed: 1) an exercise designed to reduce glycogen of type I muscle fibers, followed by a 4-km TT (EX-FIB I); 2) an exercise designed to reduce glycogen of type II muscle fibers, followed by a 4-km TT (EX-FIB II) and; 3) a 4-km TT, without the prior exercise (CONT). The muscle-glycogen-reducing exercise in both EX-FIB I and EX-FIB II was performed in the evening, ∼12 h before the 4-km TT. Performance time was increased and power output (PO) was reduced in EX-FIB I (432.8±8.3 s and 204.9±10.9 W) and EX-FIB II (428.7±6.7 s and 207.5±9.1 W) compared to CONT (420.8±6.4 s and 218.4±9.3 W; P<0.01), without a difference between EX-FIB I and EX-FIB II (P>0.05). The PO was lower in EX-FIB I than in CONT at the beginning and middle of the trial (P<0.05). The mean aerobic contribution during EX-FIB I was also significantly lower than in CONT (P<0.05), but there was no difference between CONT and EX-FIB II or between EX-FIB I and EX-FIB II (P>0.05). The integrated electromyography was unchanged between conditions (P>0.05). Performance may have been impaired in EX-FIB I due a more conservative pacing at the beginning and middle, which was associated with a reduced aerobic contribution. In turn, the PO profile adopted in EX-FIB II was also reduced throughout the trial, but the impairment in performance may be attributed to a reduced glycolytic contribution (i.e. reduced lactate accumulation).
format Online
Article
Text
id pubmed-4203780
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-42037802014-10-27 Prior Low- or High-Intensity Exercise Alters Pacing Strategy, Energy System Contribution and Performance during a 4-km Cycling Time Trial Correia-Oliveira, Carlos Rafaell Santos, Ralmony Alcantara Silva-Cavalcante, Marcos David Bertuzzi, Romulo Kiss, Maria Augusta Peduti Dal’Molin Bishop, David John Lima-Silva, Adriano Eduardo PLoS One Research Article We analyzed the influence of prior exercise designed to reduce predominantly muscle glycogen in either type I or II fibers on pacing and performance during a 4-km cycling time trial (TT). After preliminary and familiarization trials, in a randomized, repeated-measures crossover design, ten amateur cyclists performed: 1) an exercise designed to reduce glycogen of type I muscle fibers, followed by a 4-km TT (EX-FIB I); 2) an exercise designed to reduce glycogen of type II muscle fibers, followed by a 4-km TT (EX-FIB II) and; 3) a 4-km TT, without the prior exercise (CONT). The muscle-glycogen-reducing exercise in both EX-FIB I and EX-FIB II was performed in the evening, ∼12 h before the 4-km TT. Performance time was increased and power output (PO) was reduced in EX-FIB I (432.8±8.3 s and 204.9±10.9 W) and EX-FIB II (428.7±6.7 s and 207.5±9.1 W) compared to CONT (420.8±6.4 s and 218.4±9.3 W; P<0.01), without a difference between EX-FIB I and EX-FIB II (P>0.05). The PO was lower in EX-FIB I than in CONT at the beginning and middle of the trial (P<0.05). The mean aerobic contribution during EX-FIB I was also significantly lower than in CONT (P<0.05), but there was no difference between CONT and EX-FIB II or between EX-FIB I and EX-FIB II (P>0.05). The integrated electromyography was unchanged between conditions (P>0.05). Performance may have been impaired in EX-FIB I due a more conservative pacing at the beginning and middle, which was associated with a reduced aerobic contribution. In turn, the PO profile adopted in EX-FIB II was also reduced throughout the trial, but the impairment in performance may be attributed to a reduced glycolytic contribution (i.e. reduced lactate accumulation). Public Library of Science 2014-10-20 /pmc/articles/PMC4203780/ /pubmed/25330452 http://dx.doi.org/10.1371/journal.pone.0110320 Text en © 2014 Correia-Oliveira et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited.
spellingShingle Research Article
Correia-Oliveira, Carlos Rafaell
Santos, Ralmony Alcantara
Silva-Cavalcante, Marcos David
Bertuzzi, Romulo
Kiss, Maria Augusta Peduti Dal’Molin
Bishop, David John
Lima-Silva, Adriano Eduardo
Prior Low- or High-Intensity Exercise Alters Pacing Strategy, Energy System Contribution and Performance during a 4-km Cycling Time Trial
title Prior Low- or High-Intensity Exercise Alters Pacing Strategy, Energy System Contribution and Performance during a 4-km Cycling Time Trial
title_full Prior Low- or High-Intensity Exercise Alters Pacing Strategy, Energy System Contribution and Performance during a 4-km Cycling Time Trial
title_fullStr Prior Low- or High-Intensity Exercise Alters Pacing Strategy, Energy System Contribution and Performance during a 4-km Cycling Time Trial
title_full_unstemmed Prior Low- or High-Intensity Exercise Alters Pacing Strategy, Energy System Contribution and Performance during a 4-km Cycling Time Trial
title_short Prior Low- or High-Intensity Exercise Alters Pacing Strategy, Energy System Contribution and Performance during a 4-km Cycling Time Trial
title_sort prior low- or high-intensity exercise alters pacing strategy, energy system contribution and performance during a 4-km cycling time trial
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4203780/
https://www.ncbi.nlm.nih.gov/pubmed/25330452
http://dx.doi.org/10.1371/journal.pone.0110320
work_keys_str_mv AT correiaoliveiracarlosrafaell priorloworhighintensityexercisealterspacingstrategyenergysystemcontributionandperformanceduringa4kmcyclingtimetrial
AT santosralmonyalcantara priorloworhighintensityexercisealterspacingstrategyenergysystemcontributionandperformanceduringa4kmcyclingtimetrial
AT silvacavalcantemarcosdavid priorloworhighintensityexercisealterspacingstrategyenergysystemcontributionandperformanceduringa4kmcyclingtimetrial
AT bertuzziromulo priorloworhighintensityexercisealterspacingstrategyenergysystemcontributionandperformanceduringa4kmcyclingtimetrial
AT kissmariaaugustapedutidalmolin priorloworhighintensityexercisealterspacingstrategyenergysystemcontributionandperformanceduringa4kmcyclingtimetrial
AT bishopdavidjohn priorloworhighintensityexercisealterspacingstrategyenergysystemcontributionandperformanceduringa4kmcyclingtimetrial
AT limasilvaadrianoeduardo priorloworhighintensityexercisealterspacingstrategyenergysystemcontributionandperformanceduringa4kmcyclingtimetrial