Cargando…
Correction of aortic coarctation in a girl with severe PHACE syndrome
A 12-year-old Chinese girl was demonstrated multivessel distortion and malformation: aortic coarctation with the narrowest lumen diameter measuring of 4 mm located between the left common carotid artery and the left subclavian artery, a huge and thin-walled aneurysm is connected to the coarctation,...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4203972/ https://www.ncbi.nlm.nih.gov/pubmed/25312304 http://dx.doi.org/10.1186/s13019-014-0169-6 |
_version_ | 1782340475853733888 |
---|---|
author | Xiong, Lian Xia, Zhenkun Fan, Chengming Zhang, Weizhi Yang, Jinfu |
author_facet | Xiong, Lian Xia, Zhenkun Fan, Chengming Zhang, Weizhi Yang, Jinfu |
author_sort | Xiong, Lian |
collection | PubMed |
description | A 12-year-old Chinese girl was demonstrated multivessel distortion and malformation: aortic coarctation with the narrowest lumen diameter measuring of 4 mm located between the left common carotid artery and the left subclavian artery, a huge and thin-walled aneurysm is connected to the coarctation, and the descending aorta was distorted. Cerebrovascular revealed distorted arteries and a completely aberrant brain blood supply. She underwent correction of the aortic coarctation by establishing a bypass between the ascending aorta and the descending aorta using a 13-mm Gore-tex tube. Postoperative recovery was uneventful, at 6-month follow-up, the cervical vascular pulsatility was relieved and she is in good condition. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1186/s13019-014-0169-6) contains supplementary material, which is available to authorized users. |
format | Online Article Text |
id | pubmed-4203972 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-42039722014-10-22 Correction of aortic coarctation in a girl with severe PHACE syndrome Xiong, Lian Xia, Zhenkun Fan, Chengming Zhang, Weizhi Yang, Jinfu J Cardiothorac Surg Case Report A 12-year-old Chinese girl was demonstrated multivessel distortion and malformation: aortic coarctation with the narrowest lumen diameter measuring of 4 mm located between the left common carotid artery and the left subclavian artery, a huge and thin-walled aneurysm is connected to the coarctation, and the descending aorta was distorted. Cerebrovascular revealed distorted arteries and a completely aberrant brain blood supply. She underwent correction of the aortic coarctation by establishing a bypass between the ascending aorta and the descending aorta using a 13-mm Gore-tex tube. Postoperative recovery was uneventful, at 6-month follow-up, the cervical vascular pulsatility was relieved and she is in good condition. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1186/s13019-014-0169-6) contains supplementary material, which is available to authorized users. BioMed Central 2014-10-14 /pmc/articles/PMC4203972/ /pubmed/25312304 http://dx.doi.org/10.1186/s13019-014-0169-6 Text en © Xiong et al.; licensee BioMed Central Ltd. 2014 This article is published under license to BioMed Central Ltd. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Case Report Xiong, Lian Xia, Zhenkun Fan, Chengming Zhang, Weizhi Yang, Jinfu Correction of aortic coarctation in a girl with severe PHACE syndrome |
title | Correction of aortic coarctation in a girl with severe PHACE syndrome |
title_full | Correction of aortic coarctation in a girl with severe PHACE syndrome |
title_fullStr | Correction of aortic coarctation in a girl with severe PHACE syndrome |
title_full_unstemmed | Correction of aortic coarctation in a girl with severe PHACE syndrome |
title_short | Correction of aortic coarctation in a girl with severe PHACE syndrome |
title_sort | correction of aortic coarctation in a girl with severe phace syndrome |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4203972/ https://www.ncbi.nlm.nih.gov/pubmed/25312304 http://dx.doi.org/10.1186/s13019-014-0169-6 |
work_keys_str_mv | AT xionglian correctionofaorticcoarctationinagirlwithseverephacesyndrome AT xiazhenkun correctionofaorticcoarctationinagirlwithseverephacesyndrome AT fanchengming correctionofaorticcoarctationinagirlwithseverephacesyndrome AT zhangweizhi correctionofaorticcoarctationinagirlwithseverephacesyndrome AT yangjinfu correctionofaorticcoarctationinagirlwithseverephacesyndrome |