Cargando…

Effectiveness Evaluation of Skin Covers against Intravascular Brachytherapy Sources Using VARSKIN3 Code

Background and Objective: The most common intravascular brachytherapy sources include (32)P, (188)Re, (106)Rh and (90)Sr/(90)Y. In this research, skin absorbed dose for different covering materials in dealing with these sources were evaluated and the best covering material for skin protection and re...

Descripción completa

Detalles Bibliográficos
Autores principales: Baghani, H R, Nazempour, A R, Aghamiri, S M R, Hosseini Daghigh, S M, Mowlavi, A A
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Shiraz University of Medical Sciences 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4204508/
https://www.ncbi.nlm.nih.gov/pubmed/25505758
_version_ 1782340577206992896
author Baghani, H R
Nazempour, A R
Aghamiri, S M R
Hosseini Daghigh, S M
Mowlavi, A A
author_facet Baghani, H R
Nazempour, A R
Aghamiri, S M R
Hosseini Daghigh, S M
Mowlavi, A A
author_sort Baghani, H R
collection PubMed
description Background and Objective: The most common intravascular brachytherapy sources include (32)P, (188)Re, (106)Rh and (90)Sr/(90)Y. In this research, skin absorbed dose for different covering materials in dealing with these sources were evaluated and the best covering material for skin protection and reduction of absorbed dose by radiation staff was recognized and recommended. Method: Four materials including polyethylene, cotton and two different kinds of plastic were proposed as skin covers and skin absorbed dose at different depths for each kind of the materials was calculated separately using the VARSKIN3 code. Results: The results suggested that for all sources, skin absorbed dose was minimized when using polyethylene. Considering this material as skin cover, maximum and minimum doses at skin surface were related to (90)Sr/(90)Y and (106)Rh, respectively. Conclusion: polyethylene was found the most effective cover in reducing skin dose and protecting the skin. Furthermore, proper agreement between the results of VARSKIN3 and other experimental measurements indicated that VRASKIN3 is a powerful tool for skin dose calculations when working with beta emitter sources. Therefore, it can be utilized in dealing with the issue of radiation protection.
format Online
Article
Text
id pubmed-4204508
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Shiraz University of Medical Sciences
record_format MEDLINE/PubMed
spelling pubmed-42045082014-12-10 Effectiveness Evaluation of Skin Covers against Intravascular Brachytherapy Sources Using VARSKIN3 Code Baghani, H R Nazempour, A R Aghamiri, S M R Hosseini Daghigh, S M Mowlavi, A A J Biomed Phys Eng Original Article Background and Objective: The most common intravascular brachytherapy sources include (32)P, (188)Re, (106)Rh and (90)Sr/(90)Y. In this research, skin absorbed dose for different covering materials in dealing with these sources were evaluated and the best covering material for skin protection and reduction of absorbed dose by radiation staff was recognized and recommended. Method: Four materials including polyethylene, cotton and two different kinds of plastic were proposed as skin covers and skin absorbed dose at different depths for each kind of the materials was calculated separately using the VARSKIN3 code. Results: The results suggested that for all sources, skin absorbed dose was minimized when using polyethylene. Considering this material as skin cover, maximum and minimum doses at skin surface were related to (90)Sr/(90)Y and (106)Rh, respectively. Conclusion: polyethylene was found the most effective cover in reducing skin dose and protecting the skin. Furthermore, proper agreement between the results of VARSKIN3 and other experimental measurements indicated that VRASKIN3 is a powerful tool for skin dose calculations when working with beta emitter sources. Therefore, it can be utilized in dealing with the issue of radiation protection. Shiraz University of Medical Sciences 2013-12-02 /pmc/articles/PMC4204508/ /pubmed/25505758 Text en © 2013: Journal of Biomedical Physics and Engineering This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial 3.0 Unported License (http://creativecommons.org/licenses/by-nc/3.0/deed.en_US), which permits unrestricted use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Baghani, H R
Nazempour, A R
Aghamiri, S M R
Hosseini Daghigh, S M
Mowlavi, A A
Effectiveness Evaluation of Skin Covers against Intravascular Brachytherapy Sources Using VARSKIN3 Code
title Effectiveness Evaluation of Skin Covers against Intravascular Brachytherapy Sources Using VARSKIN3 Code
title_full Effectiveness Evaluation of Skin Covers against Intravascular Brachytherapy Sources Using VARSKIN3 Code
title_fullStr Effectiveness Evaluation of Skin Covers against Intravascular Brachytherapy Sources Using VARSKIN3 Code
title_full_unstemmed Effectiveness Evaluation of Skin Covers against Intravascular Brachytherapy Sources Using VARSKIN3 Code
title_short Effectiveness Evaluation of Skin Covers against Intravascular Brachytherapy Sources Using VARSKIN3 Code
title_sort effectiveness evaluation of skin covers against intravascular brachytherapy sources using varskin3 code
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4204508/
https://www.ncbi.nlm.nih.gov/pubmed/25505758
work_keys_str_mv AT baghanihr effectivenessevaluationofskincoversagainstintravascularbrachytherapysourcesusingvarskin3code
AT nazempourar effectivenessevaluationofskincoversagainstintravascularbrachytherapysourcesusingvarskin3code
AT aghamirismr effectivenessevaluationofskincoversagainstintravascularbrachytherapysourcesusingvarskin3code
AT hosseinidaghighsm effectivenessevaluationofskincoversagainstintravascularbrachytherapysourcesusingvarskin3code
AT mowlaviaa effectivenessevaluationofskincoversagainstintravascularbrachytherapysourcesusingvarskin3code