Cargando…

Noninvasive Recording of True-to-Form Fetal ECG during the Third Trimester of Pregnancy

Objective. The aim of the study was to develop a complex electrophysiological measurement system (hardware and software) which uses the methods of electrophysiology and provides significant information about the intrauterine status of the fetus, intending to obtain true-to-form, morphologically eval...

Descripción completa

Detalles Bibliográficos
Autores principales: Peterfi, Istvan, Kellenyi, Lorand, Szilagyi, Andras
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4206934/
https://www.ncbi.nlm.nih.gov/pubmed/25374606
http://dx.doi.org/10.1155/2014/285636
_version_ 1782340894336221184
author Peterfi, Istvan
Kellenyi, Lorand
Szilagyi, Andras
author_facet Peterfi, Istvan
Kellenyi, Lorand
Szilagyi, Andras
author_sort Peterfi, Istvan
collection PubMed
description Objective. The aim of the study was to develop a complex electrophysiological measurement system (hardware and software) which uses the methods of electrophysiology and provides significant information about the intrauterine status of the fetus, intending to obtain true-to-form, morphologically evaluated fetal ECG from transabdominal maternal lead. Results. The present method contains many novel ideas that allow creating true-to-form noninvasive fetal ECG in the third trimester of the pregnancy in 80% of the cases. Such ideas are the telemetric data collection, the “cleanse” of the real time recording from the maternal ECG, and the use of the cardiotocograph (CTG) that allows identifying the fetal heart events. The advantage of this developed system is that it does not require any qualified staff, because both the extraction of the information from the abdominal recording and the processing of the data are automatic. Discussion. Although the idea of a noninvasive fetal electrocardiography is more than 100 years old still there is no simple, effective, and cheap method available that would enable an extensive use. This developed system can be used in the third trimester of the pregnancy efficiently. It can produce true-to-form fetal ECGs with amplitude less than 10 µV.
format Online
Article
Text
id pubmed-4206934
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-42069342014-11-05 Noninvasive Recording of True-to-Form Fetal ECG during the Third Trimester of Pregnancy Peterfi, Istvan Kellenyi, Lorand Szilagyi, Andras Obstet Gynecol Int Research Article Objective. The aim of the study was to develop a complex electrophysiological measurement system (hardware and software) which uses the methods of electrophysiology and provides significant information about the intrauterine status of the fetus, intending to obtain true-to-form, morphologically evaluated fetal ECG from transabdominal maternal lead. Results. The present method contains many novel ideas that allow creating true-to-form noninvasive fetal ECG in the third trimester of the pregnancy in 80% of the cases. Such ideas are the telemetric data collection, the “cleanse” of the real time recording from the maternal ECG, and the use of the cardiotocograph (CTG) that allows identifying the fetal heart events. The advantage of this developed system is that it does not require any qualified staff, because both the extraction of the information from the abdominal recording and the processing of the data are automatic. Discussion. Although the idea of a noninvasive fetal electrocardiography is more than 100 years old still there is no simple, effective, and cheap method available that would enable an extensive use. This developed system can be used in the third trimester of the pregnancy efficiently. It can produce true-to-form fetal ECGs with amplitude less than 10 µV. Hindawi Publishing Corporation 2014 2014-10-08 /pmc/articles/PMC4206934/ /pubmed/25374606 http://dx.doi.org/10.1155/2014/285636 Text en Copyright © 2014 Istvan Peterfi et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Peterfi, Istvan
Kellenyi, Lorand
Szilagyi, Andras
Noninvasive Recording of True-to-Form Fetal ECG during the Third Trimester of Pregnancy
title Noninvasive Recording of True-to-Form Fetal ECG during the Third Trimester of Pregnancy
title_full Noninvasive Recording of True-to-Form Fetal ECG during the Third Trimester of Pregnancy
title_fullStr Noninvasive Recording of True-to-Form Fetal ECG during the Third Trimester of Pregnancy
title_full_unstemmed Noninvasive Recording of True-to-Form Fetal ECG during the Third Trimester of Pregnancy
title_short Noninvasive Recording of True-to-Form Fetal ECG during the Third Trimester of Pregnancy
title_sort noninvasive recording of true-to-form fetal ecg during the third trimester of pregnancy
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4206934/
https://www.ncbi.nlm.nih.gov/pubmed/25374606
http://dx.doi.org/10.1155/2014/285636
work_keys_str_mv AT peterfiistvan noninvasiverecordingoftruetoformfetalecgduringthethirdtrimesterofpregnancy
AT kellenyilorand noninvasiverecordingoftruetoformfetalecgduringthethirdtrimesterofpregnancy
AT szilagyiandras noninvasiverecordingoftruetoformfetalecgduringthethirdtrimesterofpregnancy