Cargando…

An In-Line Photonic Biosensor for Monitoring of Glucose Concentrations

This paper presents two PDMS photonic biosensor designs that can be used for continuous monitoring of glucose concentrations. The first design, the internally immobilized sensor, consists of a reactor chamber, micro-lenses and self-alignment structures for fiber optics positioning. This sensor desig...

Descripción completa

Detalles Bibliográficos
Autores principales: Al-Halhouli, Ala'aldeen, Demming, Stefanie, Alahmad, Laila, LIobera, Andreu, Büttgenbach, Stephanus
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4208143/
https://www.ncbi.nlm.nih.gov/pubmed/25157552
http://dx.doi.org/10.3390/s140915749
_version_ 1782341078975774720
author Al-Halhouli, Ala'aldeen
Demming, Stefanie
Alahmad, Laila
LIobera, Andreu
Büttgenbach, Stephanus
author_facet Al-Halhouli, Ala'aldeen
Demming, Stefanie
Alahmad, Laila
LIobera, Andreu
Büttgenbach, Stephanus
author_sort Al-Halhouli, Ala'aldeen
collection PubMed
description This paper presents two PDMS photonic biosensor designs that can be used for continuous monitoring of glucose concentrations. The first design, the internally immobilized sensor, consists of a reactor chamber, micro-lenses and self-alignment structures for fiber optics positioning. This sensor design allows optical detection of glucose concentrations under continuous glucose flow conditions of 33 μL/h based on internal co-immobilization of glucose oxidase (GOX) and horseradish peroxidase (HRP) on the internal PDMS surface of the reactor chamber. For this design, two co-immobilization methods, the simple adsorption and the covalent binding (PEG) methods were tested. Experiments showed successful results when using the covalent binding (PEG) method, where glucose concentrations up to 5 mM with a coefficient of determination (R(2)) of 0.99 and a limit of detection of 0.26 mM are detectable. The second design is a modified version of the internally immobilized sensor, where a microbead chamber and a beads filling channel are integrated into the sensor. This modification enabled external co-immobilization of enzymes covalently onto functionalized silica microbeads and allows binding a huge amount of HRP and GOX enzymes on the microbeads surfaces which increases the interaction area between immobilized enzymes and the analyte. This has a positive effect on the amount and rate of chemical reactions taking place inside the chamber. The sensor was tested under continuous glucose flow conditions and was found to be able to detect glucose concentrations up to 10 mM with R(2) of 0.98 and a limit of detection of 0.7 mM. Such results are very promising for the application in photonic LOC systems used for online analysis.
format Online
Article
Text
id pubmed-4208143
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-42081432014-10-24 An In-Line Photonic Biosensor for Monitoring of Glucose Concentrations Al-Halhouli, Ala'aldeen Demming, Stefanie Alahmad, Laila LIobera, Andreu Büttgenbach, Stephanus Sensors (Basel) Article This paper presents two PDMS photonic biosensor designs that can be used for continuous monitoring of glucose concentrations. The first design, the internally immobilized sensor, consists of a reactor chamber, micro-lenses and self-alignment structures for fiber optics positioning. This sensor design allows optical detection of glucose concentrations under continuous glucose flow conditions of 33 μL/h based on internal co-immobilization of glucose oxidase (GOX) and horseradish peroxidase (HRP) on the internal PDMS surface of the reactor chamber. For this design, two co-immobilization methods, the simple adsorption and the covalent binding (PEG) methods were tested. Experiments showed successful results when using the covalent binding (PEG) method, where glucose concentrations up to 5 mM with a coefficient of determination (R(2)) of 0.99 and a limit of detection of 0.26 mM are detectable. The second design is a modified version of the internally immobilized sensor, where a microbead chamber and a beads filling channel are integrated into the sensor. This modification enabled external co-immobilization of enzymes covalently onto functionalized silica microbeads and allows binding a huge amount of HRP and GOX enzymes on the microbeads surfaces which increases the interaction area between immobilized enzymes and the analyte. This has a positive effect on the amount and rate of chemical reactions taking place inside the chamber. The sensor was tested under continuous glucose flow conditions and was found to be able to detect glucose concentrations up to 10 mM with R(2) of 0.98 and a limit of detection of 0.7 mM. Such results are very promising for the application in photonic LOC systems used for online analysis. MDPI 2014-08-02 /pmc/articles/PMC4208143/ /pubmed/25157552 http://dx.doi.org/10.3390/s140915749 Text en © 2014 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/3.0/).
spellingShingle Article
Al-Halhouli, Ala'aldeen
Demming, Stefanie
Alahmad, Laila
LIobera, Andreu
Büttgenbach, Stephanus
An In-Line Photonic Biosensor for Monitoring of Glucose Concentrations
title An In-Line Photonic Biosensor for Monitoring of Glucose Concentrations
title_full An In-Line Photonic Biosensor for Monitoring of Glucose Concentrations
title_fullStr An In-Line Photonic Biosensor for Monitoring of Glucose Concentrations
title_full_unstemmed An In-Line Photonic Biosensor for Monitoring of Glucose Concentrations
title_short An In-Line Photonic Biosensor for Monitoring of Glucose Concentrations
title_sort in-line photonic biosensor for monitoring of glucose concentrations
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4208143/
https://www.ncbi.nlm.nih.gov/pubmed/25157552
http://dx.doi.org/10.3390/s140915749
work_keys_str_mv AT alhalhoulialaaldeen aninlinephotonicbiosensorformonitoringofglucoseconcentrations
AT demmingstefanie aninlinephotonicbiosensorformonitoringofglucoseconcentrations
AT alahmadlaila aninlinephotonicbiosensorformonitoringofglucoseconcentrations
AT lioberaandreu aninlinephotonicbiosensorformonitoringofglucoseconcentrations
AT buttgenbachstephanus aninlinephotonicbiosensorformonitoringofglucoseconcentrations
AT alhalhoulialaaldeen inlinephotonicbiosensorformonitoringofglucoseconcentrations
AT demmingstefanie inlinephotonicbiosensorformonitoringofglucoseconcentrations
AT alahmadlaila inlinephotonicbiosensorformonitoringofglucoseconcentrations
AT lioberaandreu inlinephotonicbiosensorformonitoringofglucoseconcentrations
AT buttgenbachstephanus inlinephotonicbiosensorformonitoringofglucoseconcentrations