Cargando…

Topography of retinal recovery processes in humans

BACKGROUND: The purpose of this study was to examine retinal recovery processes to pographically by the application of three flash sequences with specific interstimulus intervals. METHODS: Twelve healthy subjects underwent multifocal electroretinography with a light-emitting diode stimulator. Every...

Descripción completa

Detalles Bibliográficos
Autores principales: Mazinani, Babac E, Merx, Elke, Plange, Niklas, Walter, Peter, Roessler, Gernot F
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Dove Medical Press 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4208419/
https://www.ncbi.nlm.nih.gov/pubmed/25349472
http://dx.doi.org/10.2147/OPTH.S49708
_version_ 1782341128944615424
author Mazinani, Babac E
Merx, Elke
Plange, Niklas
Walter, Peter
Roessler, Gernot F
author_facet Mazinani, Babac E
Merx, Elke
Plange, Niklas
Walter, Peter
Roessler, Gernot F
author_sort Mazinani, Babac E
collection PubMed
description BACKGROUND: The purpose of this study was to examine retinal recovery processes to pographically by the application of three flash sequences with specific interstimulus intervals. METHODS: Twelve healthy subjects underwent multifocal electroretinography with a light-emitting diode stimulator. Every flash sequence consisted of three flashes with 25 msec between the first and the second flash and 35 msec between the second and the third flash. The interval between the third and the first flash of the next step was 85 msec. The interstimulus interval-dependent amplitude reductions of the multifocal electroretinographic response for these three intervals yielded three data points that were used to determine the complete curve of the recovery kinetics. RESULTS: Amplitude reductions were higher with shorter interstimulus intervals. The mean half-life periods of the recovery kinetics for the different concentric rings and all subjects were: ring 1, 29.3±5.9 msec; ring 2, 24.2±6.4 msec; ring 3, 23±4.1 msec; ring 4, 23.1±4.6 msec; and ring 5, 22.3±4.4 msec. The differences between the first and all other rings were statistically significant (P<0.05). CONCLUSION: The kinetics of the amplitude recovery after short interstimulus intervals showed a spatial distribution, with faster recovery toward the macular periphery.
format Online
Article
Text
id pubmed-4208419
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Dove Medical Press
record_format MEDLINE/PubMed
spelling pubmed-42084192014-10-27 Topography of retinal recovery processes in humans Mazinani, Babac E Merx, Elke Plange, Niklas Walter, Peter Roessler, Gernot F Clin Ophthalmol Original Research BACKGROUND: The purpose of this study was to examine retinal recovery processes to pographically by the application of three flash sequences with specific interstimulus intervals. METHODS: Twelve healthy subjects underwent multifocal electroretinography with a light-emitting diode stimulator. Every flash sequence consisted of three flashes with 25 msec between the first and the second flash and 35 msec between the second and the third flash. The interval between the third and the first flash of the next step was 85 msec. The interstimulus interval-dependent amplitude reductions of the multifocal electroretinographic response for these three intervals yielded three data points that were used to determine the complete curve of the recovery kinetics. RESULTS: Amplitude reductions were higher with shorter interstimulus intervals. The mean half-life periods of the recovery kinetics for the different concentric rings and all subjects were: ring 1, 29.3±5.9 msec; ring 2, 24.2±6.4 msec; ring 3, 23±4.1 msec; ring 4, 23.1±4.6 msec; and ring 5, 22.3±4.4 msec. The differences between the first and all other rings were statistically significant (P<0.05). CONCLUSION: The kinetics of the amplitude recovery after short interstimulus intervals showed a spatial distribution, with faster recovery toward the macular periphery. Dove Medical Press 2014-10-20 /pmc/articles/PMC4208419/ /pubmed/25349472 http://dx.doi.org/10.2147/OPTH.S49708 Text en © 2014 Mazinani et al. This work is published by Dove Medical Press Limited, and licensed under Creative Commons Attribution – Non Commercial (unported, v3.0) License The full terms of the License are available at http://creativecommons.org/licenses/by-nc/3.0/. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed.
spellingShingle Original Research
Mazinani, Babac E
Merx, Elke
Plange, Niklas
Walter, Peter
Roessler, Gernot F
Topography of retinal recovery processes in humans
title Topography of retinal recovery processes in humans
title_full Topography of retinal recovery processes in humans
title_fullStr Topography of retinal recovery processes in humans
title_full_unstemmed Topography of retinal recovery processes in humans
title_short Topography of retinal recovery processes in humans
title_sort topography of retinal recovery processes in humans
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4208419/
https://www.ncbi.nlm.nih.gov/pubmed/25349472
http://dx.doi.org/10.2147/OPTH.S49708
work_keys_str_mv AT mazinanibabace topographyofretinalrecoveryprocessesinhumans
AT merxelke topographyofretinalrecoveryprocessesinhumans
AT plangeniklas topographyofretinalrecoveryprocessesinhumans
AT walterpeter topographyofretinalrecoveryprocessesinhumans
AT roesslergernotf topographyofretinalrecoveryprocessesinhumans