Clinical biochemistry laboratory rejection rates due to various types of preanalytical errors
INTRODUCTION: Preanalytical errors, along the process from the beginning of test requests to the admissions of the specimens to the laboratory, cause the rejection of samples. The aim of this study was to better explain the reasons of rejected samples, regarding to their rates in certain test groups...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Croatian Society of Medical Biochemistry and Laboratory Medicine
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4210258/ https://www.ncbi.nlm.nih.gov/pubmed/25351356 http://dx.doi.org/10.11613/BM.2014.040 |
_version_ | 1782341353658646528 |
---|---|
author | Atay, Aysenur Demir, Leyla Cuhadar, Serap Saglam, Gulcan Unal, Hulya Aksun, Saliha Arslan, Banu Ozkan, Asuman Sutcu, Recep |
author_facet | Atay, Aysenur Demir, Leyla Cuhadar, Serap Saglam, Gulcan Unal, Hulya Aksun, Saliha Arslan, Banu Ozkan, Asuman Sutcu, Recep |
author_sort | Atay, Aysenur |
collection | PubMed |
description | INTRODUCTION: Preanalytical errors, along the process from the beginning of test requests to the admissions of the specimens to the laboratory, cause the rejection of samples. The aim of this study was to better explain the reasons of rejected samples, regarding to their rates in certain test groups in our laboratory. MATERIALS AND METHODS: This preliminary study was designed on the rejected samples in one-year period, based on the rates and types of inappropriateness. Test requests and blood samples of clinical chemistry, immunoassay, hematology, glycated hemoglobin, coagulation and erythrocyte sedimentation rate test units were evaluated. Types of inappropriateness were evaluated as follows: improperly labelled samples, hemolysed, clotted specimen, insufficient volume of specimen and total request errors. RESULTS: A total of 5,183,582 test requests from 1,035,743 blood collection tubes were considered. The total rejection rate was 0.65 %. The rejection rate of coagulation group was significantly higher (2.28%) than the other test groups (P < 0.001) including insufficient volume of specimen error rate as 1.38%. Rejection rates of hemolysis, clotted specimen and insufficient volume of sample error were found to be 8%, 24% and 34%, respectively. Total request errors, particularly, for unintelligible requests were 32% of the total for inpatients. CONCLUSIONS: The errors were especially attributable to unintelligible requests of inappropriate test requests, improperly labelled samples for inpatients and blood drawing errors especially due to insufficient volume of specimens in a coagulation test group. Further studies should be performed after corrective and preventive actions to detect a possible decrease in rejecting samples. |
format | Online Article Text |
id | pubmed-4210258 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | Croatian Society of Medical Biochemistry and Laboratory Medicine |
record_format | MEDLINE/PubMed |
spelling | pubmed-42102582014-10-28 Clinical biochemistry laboratory rejection rates due to various types of preanalytical errors Atay, Aysenur Demir, Leyla Cuhadar, Serap Saglam, Gulcan Unal, Hulya Aksun, Saliha Arslan, Banu Ozkan, Asuman Sutcu, Recep Biochem Med (Zagreb) Original Papers INTRODUCTION: Preanalytical errors, along the process from the beginning of test requests to the admissions of the specimens to the laboratory, cause the rejection of samples. The aim of this study was to better explain the reasons of rejected samples, regarding to their rates in certain test groups in our laboratory. MATERIALS AND METHODS: This preliminary study was designed on the rejected samples in one-year period, based on the rates and types of inappropriateness. Test requests and blood samples of clinical chemistry, immunoassay, hematology, glycated hemoglobin, coagulation and erythrocyte sedimentation rate test units were evaluated. Types of inappropriateness were evaluated as follows: improperly labelled samples, hemolysed, clotted specimen, insufficient volume of specimen and total request errors. RESULTS: A total of 5,183,582 test requests from 1,035,743 blood collection tubes were considered. The total rejection rate was 0.65 %. The rejection rate of coagulation group was significantly higher (2.28%) than the other test groups (P < 0.001) including insufficient volume of specimen error rate as 1.38%. Rejection rates of hemolysis, clotted specimen and insufficient volume of sample error were found to be 8%, 24% and 34%, respectively. Total request errors, particularly, for unintelligible requests were 32% of the total for inpatients. CONCLUSIONS: The errors were especially attributable to unintelligible requests of inappropriate test requests, improperly labelled samples for inpatients and blood drawing errors especially due to insufficient volume of specimens in a coagulation test group. Further studies should be performed after corrective and preventive actions to detect a possible decrease in rejecting samples. Croatian Society of Medical Biochemistry and Laboratory Medicine 2014-10-15 /pmc/articles/PMC4210258/ /pubmed/25351356 http://dx.doi.org/10.11613/BM.2014.040 Text en © Copyright by Croatian Society of Medical Biochemistry and Laboratory Medicine. This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc-nd/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Papers Atay, Aysenur Demir, Leyla Cuhadar, Serap Saglam, Gulcan Unal, Hulya Aksun, Saliha Arslan, Banu Ozkan, Asuman Sutcu, Recep Clinical biochemistry laboratory rejection rates due to various types of preanalytical errors |
title | Clinical biochemistry laboratory rejection rates due to various types of preanalytical errors |
title_full | Clinical biochemistry laboratory rejection rates due to various types of preanalytical errors |
title_fullStr | Clinical biochemistry laboratory rejection rates due to various types of preanalytical errors |
title_full_unstemmed | Clinical biochemistry laboratory rejection rates due to various types of preanalytical errors |
title_short | Clinical biochemistry laboratory rejection rates due to various types of preanalytical errors |
title_sort | clinical biochemistry laboratory rejection rates due to various types of preanalytical errors |
topic | Original Papers |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4210258/ https://www.ncbi.nlm.nih.gov/pubmed/25351356 http://dx.doi.org/10.11613/BM.2014.040 |
work_keys_str_mv | AT atayaysenur clinicalbiochemistrylaboratoryrejectionratesduetovarioustypesofpreanalyticalerrors AT demirleyla clinicalbiochemistrylaboratoryrejectionratesduetovarioustypesofpreanalyticalerrors AT cuhadarserap clinicalbiochemistrylaboratoryrejectionratesduetovarioustypesofpreanalyticalerrors AT saglamgulcan clinicalbiochemistrylaboratoryrejectionratesduetovarioustypesofpreanalyticalerrors AT unalhulya clinicalbiochemistrylaboratoryrejectionratesduetovarioustypesofpreanalyticalerrors AT aksunsaliha clinicalbiochemistrylaboratoryrejectionratesduetovarioustypesofpreanalyticalerrors AT arslanbanu clinicalbiochemistrylaboratoryrejectionratesduetovarioustypesofpreanalyticalerrors AT ozkanasuman clinicalbiochemistrylaboratoryrejectionratesduetovarioustypesofpreanalyticalerrors AT sutcurecep clinicalbiochemistrylaboratoryrejectionratesduetovarioustypesofpreanalyticalerrors |