Cargando…

Clinical biochemistry laboratory rejection rates due to various types of preanalytical errors

INTRODUCTION: Preanalytical errors, along the process from the beginning of test requests to the admissions of the specimens to the laboratory, cause the rejection of samples. The aim of this study was to better explain the reasons of rejected samples, regarding to their rates in certain test groups...

Descripción completa

Detalles Bibliográficos
Autores principales: Atay, Aysenur, Demir, Leyla, Cuhadar, Serap, Saglam, Gulcan, Unal, Hulya, Aksun, Saliha, Arslan, Banu, Ozkan, Asuman, Sutcu, Recep
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Croatian Society of Medical Biochemistry and Laboratory Medicine 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4210258/
https://www.ncbi.nlm.nih.gov/pubmed/25351356
http://dx.doi.org/10.11613/BM.2014.040
_version_ 1782341353658646528
author Atay, Aysenur
Demir, Leyla
Cuhadar, Serap
Saglam, Gulcan
Unal, Hulya
Aksun, Saliha
Arslan, Banu
Ozkan, Asuman
Sutcu, Recep
author_facet Atay, Aysenur
Demir, Leyla
Cuhadar, Serap
Saglam, Gulcan
Unal, Hulya
Aksun, Saliha
Arslan, Banu
Ozkan, Asuman
Sutcu, Recep
author_sort Atay, Aysenur
collection PubMed
description INTRODUCTION: Preanalytical errors, along the process from the beginning of test requests to the admissions of the specimens to the laboratory, cause the rejection of samples. The aim of this study was to better explain the reasons of rejected samples, regarding to their rates in certain test groups in our laboratory. MATERIALS AND METHODS: This preliminary study was designed on the rejected samples in one-year period, based on the rates and types of inappropriateness. Test requests and blood samples of clinical chemistry, immunoassay, hematology, glycated hemoglobin, coagulation and erythrocyte sedimentation rate test units were evaluated. Types of inappropriateness were evaluated as follows: improperly labelled samples, hemolysed, clotted specimen, insufficient volume of specimen and total request errors. RESULTS: A total of 5,183,582 test requests from 1,035,743 blood collection tubes were considered. The total rejection rate was 0.65 %. The rejection rate of coagulation group was significantly higher (2.28%) than the other test groups (P < 0.001) including insufficient volume of specimen error rate as 1.38%. Rejection rates of hemolysis, clotted specimen and insufficient volume of sample error were found to be 8%, 24% and 34%, respectively. Total request errors, particularly, for unintelligible requests were 32% of the total for inpatients. CONCLUSIONS: The errors were especially attributable to unintelligible requests of inappropriate test requests, improperly labelled samples for inpatients and blood drawing errors especially due to insufficient volume of specimens in a coagulation test group. Further studies should be performed after corrective and preventive actions to detect a possible decrease in rejecting samples.
format Online
Article
Text
id pubmed-4210258
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Croatian Society of Medical Biochemistry and Laboratory Medicine
record_format MEDLINE/PubMed
spelling pubmed-42102582014-10-28 Clinical biochemistry laboratory rejection rates due to various types of preanalytical errors Atay, Aysenur Demir, Leyla Cuhadar, Serap Saglam, Gulcan Unal, Hulya Aksun, Saliha Arslan, Banu Ozkan, Asuman Sutcu, Recep Biochem Med (Zagreb) Original Papers INTRODUCTION: Preanalytical errors, along the process from the beginning of test requests to the admissions of the specimens to the laboratory, cause the rejection of samples. The aim of this study was to better explain the reasons of rejected samples, regarding to their rates in certain test groups in our laboratory. MATERIALS AND METHODS: This preliminary study was designed on the rejected samples in one-year period, based on the rates and types of inappropriateness. Test requests and blood samples of clinical chemistry, immunoassay, hematology, glycated hemoglobin, coagulation and erythrocyte sedimentation rate test units were evaluated. Types of inappropriateness were evaluated as follows: improperly labelled samples, hemolysed, clotted specimen, insufficient volume of specimen and total request errors. RESULTS: A total of 5,183,582 test requests from 1,035,743 blood collection tubes were considered. The total rejection rate was 0.65 %. The rejection rate of coagulation group was significantly higher (2.28%) than the other test groups (P < 0.001) including insufficient volume of specimen error rate as 1.38%. Rejection rates of hemolysis, clotted specimen and insufficient volume of sample error were found to be 8%, 24% and 34%, respectively. Total request errors, particularly, for unintelligible requests were 32% of the total for inpatients. CONCLUSIONS: The errors were especially attributable to unintelligible requests of inappropriate test requests, improperly labelled samples for inpatients and blood drawing errors especially due to insufficient volume of specimens in a coagulation test group. Further studies should be performed after corrective and preventive actions to detect a possible decrease in rejecting samples. Croatian Society of Medical Biochemistry and Laboratory Medicine 2014-10-15 /pmc/articles/PMC4210258/ /pubmed/25351356 http://dx.doi.org/10.11613/BM.2014.040 Text en © Copyright by Croatian Society of Medical Biochemistry and Laboratory Medicine. This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc-nd/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Papers
Atay, Aysenur
Demir, Leyla
Cuhadar, Serap
Saglam, Gulcan
Unal, Hulya
Aksun, Saliha
Arslan, Banu
Ozkan, Asuman
Sutcu, Recep
Clinical biochemistry laboratory rejection rates due to various types of preanalytical errors
title Clinical biochemistry laboratory rejection rates due to various types of preanalytical errors
title_full Clinical biochemistry laboratory rejection rates due to various types of preanalytical errors
title_fullStr Clinical biochemistry laboratory rejection rates due to various types of preanalytical errors
title_full_unstemmed Clinical biochemistry laboratory rejection rates due to various types of preanalytical errors
title_short Clinical biochemistry laboratory rejection rates due to various types of preanalytical errors
title_sort clinical biochemistry laboratory rejection rates due to various types of preanalytical errors
topic Original Papers
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4210258/
https://www.ncbi.nlm.nih.gov/pubmed/25351356
http://dx.doi.org/10.11613/BM.2014.040
work_keys_str_mv AT atayaysenur clinicalbiochemistrylaboratoryrejectionratesduetovarioustypesofpreanalyticalerrors
AT demirleyla clinicalbiochemistrylaboratoryrejectionratesduetovarioustypesofpreanalyticalerrors
AT cuhadarserap clinicalbiochemistrylaboratoryrejectionratesduetovarioustypesofpreanalyticalerrors
AT saglamgulcan clinicalbiochemistrylaboratoryrejectionratesduetovarioustypesofpreanalyticalerrors
AT unalhulya clinicalbiochemistrylaboratoryrejectionratesduetovarioustypesofpreanalyticalerrors
AT aksunsaliha clinicalbiochemistrylaboratoryrejectionratesduetovarioustypesofpreanalyticalerrors
AT arslanbanu clinicalbiochemistrylaboratoryrejectionratesduetovarioustypesofpreanalyticalerrors
AT ozkanasuman clinicalbiochemistrylaboratoryrejectionratesduetovarioustypesofpreanalyticalerrors
AT sutcurecep clinicalbiochemistrylaboratoryrejectionratesduetovarioustypesofpreanalyticalerrors