Three dimensional finite element analysis of the stress distribution around the mandibular posterior implant during non-working movement according to the amount of cantilever
PURPOSE: In case of large horizontal discrepancy of alveolar ridge due to severe resorption, cantilevered crown is usually an unavoidable treatment modality. The purpose of this study was to evaluate the clinical criteria for the placement of the aforementioned implant crown. MATERIALS AND METHODS:...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Korean Academy of Prosthodontics
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4211052/ https://www.ncbi.nlm.nih.gov/pubmed/25352958 http://dx.doi.org/10.4047/jap.2014.6.5.361 |
_version_ | 1782341502823825408 |
---|---|
author | Park, Ji-Man Kim, Hyun-Joo Park, Eun-Jin Kim, Myung-Rae Kim, Sun-Jong |
author_facet | Park, Ji-Man Kim, Hyun-Joo Park, Eun-Jin Kim, Myung-Rae Kim, Sun-Jong |
author_sort | Park, Ji-Man |
collection | PubMed |
description | PURPOSE: In case of large horizontal discrepancy of alveolar ridge due to severe resorption, cantilevered crown is usually an unavoidable treatment modality. The purpose of this study was to evaluate the clinical criteria for the placement of the aforementioned implant crown. MATERIALS AND METHODS: The mandible model with 2 mm thick cortical bone and cancellous bone was fabricated from CT cross-section image. An external connection type implant was installed and cantilevered crowns with increasing offset of 3, 4, 5, 6, and 7 mm were connected. Vertical load and 30° oblique load of 300 N was applied and stress around bone and implant component was analyzed. A total of 14 cases were modeled and finite element analysis was performed using COSMOS Works (Solid works Inc, USA). RESULTS: As for the location of the vertical load, the maximum stress generated on the lingual side of the implant became larger according to the increase of offset distance. When the oblique load was applied at 30°, the maximum stress was generated on the buccal side and its magnitude gradually decreased as the distance of the offset load increased to 5 mm. After that point, the magnitude of implant component's stress increased gradually. CONCLUSION: The results of this study suggest that for the patient with atrophied alveolar ridge following the loss of molar teeth, von-Mises stress on implant components was the lowest under the 30° oblique load at the 5 mm offset point. Further studies for the various crown height and numbers of occusal points are needed to generalize the conclusion of present study. |
format | Online Article Text |
id | pubmed-4211052 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | The Korean Academy of Prosthodontics |
record_format | MEDLINE/PubMed |
spelling | pubmed-42110522014-10-28 Three dimensional finite element analysis of the stress distribution around the mandibular posterior implant during non-working movement according to the amount of cantilever Park, Ji-Man Kim, Hyun-Joo Park, Eun-Jin Kim, Myung-Rae Kim, Sun-Jong J Adv Prosthodont Original Article PURPOSE: In case of large horizontal discrepancy of alveolar ridge due to severe resorption, cantilevered crown is usually an unavoidable treatment modality. The purpose of this study was to evaluate the clinical criteria for the placement of the aforementioned implant crown. MATERIALS AND METHODS: The mandible model with 2 mm thick cortical bone and cancellous bone was fabricated from CT cross-section image. An external connection type implant was installed and cantilevered crowns with increasing offset of 3, 4, 5, 6, and 7 mm were connected. Vertical load and 30° oblique load of 300 N was applied and stress around bone and implant component was analyzed. A total of 14 cases were modeled and finite element analysis was performed using COSMOS Works (Solid works Inc, USA). RESULTS: As for the location of the vertical load, the maximum stress generated on the lingual side of the implant became larger according to the increase of offset distance. When the oblique load was applied at 30°, the maximum stress was generated on the buccal side and its magnitude gradually decreased as the distance of the offset load increased to 5 mm. After that point, the magnitude of implant component's stress increased gradually. CONCLUSION: The results of this study suggest that for the patient with atrophied alveolar ridge following the loss of molar teeth, von-Mises stress on implant components was the lowest under the 30° oblique load at the 5 mm offset point. Further studies for the various crown height and numbers of occusal points are needed to generalize the conclusion of present study. The Korean Academy of Prosthodontics 2014-10 2014-10-21 /pmc/articles/PMC4211052/ /pubmed/25352958 http://dx.doi.org/10.4047/jap.2014.6.5.361 Text en © 2014 The Korean Academy of Prosthodontics http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Park, Ji-Man Kim, Hyun-Joo Park, Eun-Jin Kim, Myung-Rae Kim, Sun-Jong Three dimensional finite element analysis of the stress distribution around the mandibular posterior implant during non-working movement according to the amount of cantilever |
title | Three dimensional finite element analysis of the stress distribution around the mandibular posterior implant during non-working movement according to the amount of cantilever |
title_full | Three dimensional finite element analysis of the stress distribution around the mandibular posterior implant during non-working movement according to the amount of cantilever |
title_fullStr | Three dimensional finite element analysis of the stress distribution around the mandibular posterior implant during non-working movement according to the amount of cantilever |
title_full_unstemmed | Three dimensional finite element analysis of the stress distribution around the mandibular posterior implant during non-working movement according to the amount of cantilever |
title_short | Three dimensional finite element analysis of the stress distribution around the mandibular posterior implant during non-working movement according to the amount of cantilever |
title_sort | three dimensional finite element analysis of the stress distribution around the mandibular posterior implant during non-working movement according to the amount of cantilever |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4211052/ https://www.ncbi.nlm.nih.gov/pubmed/25352958 http://dx.doi.org/10.4047/jap.2014.6.5.361 |
work_keys_str_mv | AT parkjiman threedimensionalfiniteelementanalysisofthestressdistributionaroundthemandibularposteriorimplantduringnonworkingmovementaccordingtotheamountofcantilever AT kimhyunjoo threedimensionalfiniteelementanalysisofthestressdistributionaroundthemandibularposteriorimplantduringnonworkingmovementaccordingtotheamountofcantilever AT parkeunjin threedimensionalfiniteelementanalysisofthestressdistributionaroundthemandibularposteriorimplantduringnonworkingmovementaccordingtotheamountofcantilever AT kimmyungrae threedimensionalfiniteelementanalysisofthestressdistributionaroundthemandibularposteriorimplantduringnonworkingmovementaccordingtotheamountofcantilever AT kimsunjong threedimensionalfiniteelementanalysisofthestressdistributionaroundthemandibularposteriorimplantduringnonworkingmovementaccordingtotheamountofcantilever |