Cargando…
Comparison of Total Variation with a Motion Estimation Based Compressed Sensing Approach for Self-Gated Cardiac Cine MRI in Small Animal Studies
PURPOSE: Compressed sensing (CS) has been widely applied to prospective cardiac cine MRI. The aim of this work is to study the benefits obtained by including motion estimation in the CS framework for small-animal retrospective cardiac cine. METHODS: We propose a novel B-spline-based compressed sensi...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4211709/ https://www.ncbi.nlm.nih.gov/pubmed/25350290 http://dx.doi.org/10.1371/journal.pone.0110594 |
_version_ | 1782341617194106880 |
---|---|
author | Abascal, Juan F. P. J. Montesinos, Paula Marinetto, Eugenio Pascau, Javier Desco, Manuel |
author_facet | Abascal, Juan F. P. J. Montesinos, Paula Marinetto, Eugenio Pascau, Javier Desco, Manuel |
author_sort | Abascal, Juan F. P. J. |
collection | PubMed |
description | PURPOSE: Compressed sensing (CS) has been widely applied to prospective cardiac cine MRI. The aim of this work is to study the benefits obtained by including motion estimation in the CS framework for small-animal retrospective cardiac cine. METHODS: We propose a novel B-spline-based compressed sensing method (SPLICS) that includes motion estimation and generalizes previous spatiotemporal total variation (ST-TV) methods by taking into account motion between frames. In addition, we assess the effect of an optimum weighting between spatial and temporal sparsity to further improve results. Both methods were implemented using the efficient Split Bregman methodology and were evaluated on rat data comparing animals with myocardial infarction with controls for several acceleration factors. RESULTS: ST-TV with optimum selection of the weighting sparsity parameter led to results similar to those of SPLICS; ST-TV with large relative temporal sparsity led to temporal blurring effects. However, SPLICS always properly corrected temporal blurring, independently of the weighting parameter. At acceleration factors of 15, SPLICS did not distort temporal intensity information but led to some artefacts and slight over-smoothing. At an acceleration factor of 7, images were reconstructed without significant loss of quality. CONCLUSION: We have validated SPLICS for retrospective cardiac cine in small animal, achieving high acceleration factors. In addition, we have shown that motion modelling may not be essential for retrospective cine and that similar results can be obtained by using ST-TV provided that an optimum selection of the spatiotemporal sparsity weighting parameter is performed. |
format | Online Article Text |
id | pubmed-4211709 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-42117092014-11-05 Comparison of Total Variation with a Motion Estimation Based Compressed Sensing Approach for Self-Gated Cardiac Cine MRI in Small Animal Studies Abascal, Juan F. P. J. Montesinos, Paula Marinetto, Eugenio Pascau, Javier Desco, Manuel PLoS One Research Article PURPOSE: Compressed sensing (CS) has been widely applied to prospective cardiac cine MRI. The aim of this work is to study the benefits obtained by including motion estimation in the CS framework for small-animal retrospective cardiac cine. METHODS: We propose a novel B-spline-based compressed sensing method (SPLICS) that includes motion estimation and generalizes previous spatiotemporal total variation (ST-TV) methods by taking into account motion between frames. In addition, we assess the effect of an optimum weighting between spatial and temporal sparsity to further improve results. Both methods were implemented using the efficient Split Bregman methodology and were evaluated on rat data comparing animals with myocardial infarction with controls for several acceleration factors. RESULTS: ST-TV with optimum selection of the weighting sparsity parameter led to results similar to those of SPLICS; ST-TV with large relative temporal sparsity led to temporal blurring effects. However, SPLICS always properly corrected temporal blurring, independently of the weighting parameter. At acceleration factors of 15, SPLICS did not distort temporal intensity information but led to some artefacts and slight over-smoothing. At an acceleration factor of 7, images were reconstructed without significant loss of quality. CONCLUSION: We have validated SPLICS for retrospective cardiac cine in small animal, achieving high acceleration factors. In addition, we have shown that motion modelling may not be essential for retrospective cine and that similar results can be obtained by using ST-TV provided that an optimum selection of the spatiotemporal sparsity weighting parameter is performed. Public Library of Science 2014-10-28 /pmc/articles/PMC4211709/ /pubmed/25350290 http://dx.doi.org/10.1371/journal.pone.0110594 Text en © 2014 Abascal et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited. |
spellingShingle | Research Article Abascal, Juan F. P. J. Montesinos, Paula Marinetto, Eugenio Pascau, Javier Desco, Manuel Comparison of Total Variation with a Motion Estimation Based Compressed Sensing Approach for Self-Gated Cardiac Cine MRI in Small Animal Studies |
title | Comparison of Total Variation with a Motion Estimation Based Compressed Sensing Approach for Self-Gated Cardiac Cine MRI in Small Animal Studies |
title_full | Comparison of Total Variation with a Motion Estimation Based Compressed Sensing Approach for Self-Gated Cardiac Cine MRI in Small Animal Studies |
title_fullStr | Comparison of Total Variation with a Motion Estimation Based Compressed Sensing Approach for Self-Gated Cardiac Cine MRI in Small Animal Studies |
title_full_unstemmed | Comparison of Total Variation with a Motion Estimation Based Compressed Sensing Approach for Self-Gated Cardiac Cine MRI in Small Animal Studies |
title_short | Comparison of Total Variation with a Motion Estimation Based Compressed Sensing Approach for Self-Gated Cardiac Cine MRI in Small Animal Studies |
title_sort | comparison of total variation with a motion estimation based compressed sensing approach for self-gated cardiac cine mri in small animal studies |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4211709/ https://www.ncbi.nlm.nih.gov/pubmed/25350290 http://dx.doi.org/10.1371/journal.pone.0110594 |
work_keys_str_mv | AT abascaljuanfpj comparisonoftotalvariationwithamotionestimationbasedcompressedsensingapproachforselfgatedcardiaccinemriinsmallanimalstudies AT montesinospaula comparisonoftotalvariationwithamotionestimationbasedcompressedsensingapproachforselfgatedcardiaccinemriinsmallanimalstudies AT marinettoeugenio comparisonoftotalvariationwithamotionestimationbasedcompressedsensingapproachforselfgatedcardiaccinemriinsmallanimalstudies AT pascaujavier comparisonoftotalvariationwithamotionestimationbasedcompressedsensingapproachforselfgatedcardiaccinemriinsmallanimalstudies AT descomanuel comparisonoftotalvariationwithamotionestimationbasedcompressedsensingapproachforselfgatedcardiaccinemriinsmallanimalstudies |