Cargando…

Standardization of ABO Antibody Titer Measurement at Laboratories in Korea

BACKGROUND: Measurement of the ABO antibody (Ab) titer is important in ABO-incompatible transplantation. However, to the best of our knowledge, no standard protocol or external survey program to measure the ABO Ab titer has been established in Korea. We investigated the current status of ABO Ab tite...

Descripción completa

Detalles Bibliográficos
Autores principales: Lim, Young Ae, Kang, Seon Joo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Society for Laboratory Medicine 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4215415/
https://www.ncbi.nlm.nih.gov/pubmed/25368821
http://dx.doi.org/10.3343/alm.2014.34.6.456
_version_ 1782342089552429056
author Lim, Young Ae
Kang, Seon Joo
author_facet Lim, Young Ae
Kang, Seon Joo
author_sort Lim, Young Ae
collection PubMed
description BACKGROUND: Measurement of the ABO antibody (Ab) titer is important in ABO-incompatible transplantation. However, to the best of our knowledge, no standard protocol or external survey program to measure the ABO Ab titer has been established in Korea. We investigated the current status of ABO Ab titer measurements at various laboratories in Korea and the impact of the protocol provided to reduce interlaboratory variations in the methods and results of ABO Ab titers. METHODS: The Korean external quality assessment of blood bank laboratories sent external survey samples with a questionnaire to 68 laboratories across Korea for the measurement of ABO Ab titers in May 2012. After 6 months, a second set of survey samples were sent with a standard protocol to 53 of the previously surveyed laboratories. The protocol recommended incubation at room temperature only and use of the indirect antihuman globulin method for the tube test as well as and the column agglutination test (CAT). RESULTS: Several interlaboratory variations were observed in the results, technical procedures, and methods selected for measurement. We found that 80.4% laboratories hoped to change their protocol to the provisional one. Additionally, CAT showed significantly lower variation among laboratories (P=0.006) than the tube test. CONCLUSIONS: Our study provides baseline data regarding the current status of ABO Ab titer measurement in Korea. The standard protocol and external survey were helpful to standardize the technical procedures and select methods for ABO Ab titer measurement.
format Online
Article
Text
id pubmed-4215415
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher The Korean Society for Laboratory Medicine
record_format MEDLINE/PubMed
spelling pubmed-42154152014-11-03 Standardization of ABO Antibody Titer Measurement at Laboratories in Korea Lim, Young Ae Kang, Seon Joo Ann Lab Med Original Article BACKGROUND: Measurement of the ABO antibody (Ab) titer is important in ABO-incompatible transplantation. However, to the best of our knowledge, no standard protocol or external survey program to measure the ABO Ab titer has been established in Korea. We investigated the current status of ABO Ab titer measurements at various laboratories in Korea and the impact of the protocol provided to reduce interlaboratory variations in the methods and results of ABO Ab titers. METHODS: The Korean external quality assessment of blood bank laboratories sent external survey samples with a questionnaire to 68 laboratories across Korea for the measurement of ABO Ab titers in May 2012. After 6 months, a second set of survey samples were sent with a standard protocol to 53 of the previously surveyed laboratories. The protocol recommended incubation at room temperature only and use of the indirect antihuman globulin method for the tube test as well as and the column agglutination test (CAT). RESULTS: Several interlaboratory variations were observed in the results, technical procedures, and methods selected for measurement. We found that 80.4% laboratories hoped to change their protocol to the provisional one. Additionally, CAT showed significantly lower variation among laboratories (P=0.006) than the tube test. CONCLUSIONS: Our study provides baseline data regarding the current status of ABO Ab titer measurement in Korea. The standard protocol and external survey were helpful to standardize the technical procedures and select methods for ABO Ab titer measurement. The Korean Society for Laboratory Medicine 2014-11 2014-10-28 /pmc/articles/PMC4215415/ /pubmed/25368821 http://dx.doi.org/10.3343/alm.2014.34.6.456 Text en © The Korean Society for Laboratory Medicine. http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Lim, Young Ae
Kang, Seon Joo
Standardization of ABO Antibody Titer Measurement at Laboratories in Korea
title Standardization of ABO Antibody Titer Measurement at Laboratories in Korea
title_full Standardization of ABO Antibody Titer Measurement at Laboratories in Korea
title_fullStr Standardization of ABO Antibody Titer Measurement at Laboratories in Korea
title_full_unstemmed Standardization of ABO Antibody Titer Measurement at Laboratories in Korea
title_short Standardization of ABO Antibody Titer Measurement at Laboratories in Korea
title_sort standardization of abo antibody titer measurement at laboratories in korea
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4215415/
https://www.ncbi.nlm.nih.gov/pubmed/25368821
http://dx.doi.org/10.3343/alm.2014.34.6.456
work_keys_str_mv AT limyoungae standardizationofaboantibodytitermeasurementatlaboratoriesinkorea
AT kangseonjoo standardizationofaboantibodytitermeasurementatlaboratoriesinkorea