Exchanging Catheters Over a Single Transseptal Sheath During Left Atrial Ablation is Associated with a Higher Risk for Silent Cerebral Events
BACKGROUND: Silent cerebral events (SCE) have been identified on magnetic resonance imaging (MRI) in asymptomatic patients after atrial fibrillation (AF) ablation. Procedural determinants influencing the risk for SCE still remain unclear. OBJECTIVE: Comparing the risk for SCE depending on exchanges...
Autores principales: | Deneke, Thomas, Nentwich, Karin, Schmitt, Rainer, Christhopoulos, Georgios, Krug, Joachim, Di Biase, Luigi, Natale, Andrea, Szollosi, Atilla, Mugge, Andreas, Muller, Patrick, Dietrich, Johannes W, Shin, Dong-In, Kerber, Sebastian, Schade, Anja |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Indian Heart Rhythm Society
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4217296/ https://www.ncbi.nlm.nih.gov/pubmed/25408564 |
Ejemplares similares
-
Eliminating transseptal sheath exchange for pulsed field ablation procedures using a direct over-the-needle transseptal access with the Faradrive sheath
por: Kueffer, Thomas, et al.
Publicado: (2023) -
Transseptal removal of fractured guide extension catheter using deflectable sheath
por: Gasior, Pawel, et al.
Publicado: (2019) -
Solving difficulties in transseptal sheath crossing: The shoehorn technique
por: Benezet‐Mazuecos, Juan, et al.
Publicado: (2023) -
Transseptal puncture facilitated by “reverse tenting” using a left atrial ablation catheter
por: Habibi, Mohammadali, et al.
Publicado: (2018) -
Intra-atrial endothelial lesion resulting from transseptal puncture for catheter ablation of atrial fibrillation
por: Genz, Conrad, et al.
Publicado: (2012)