The use of FOCUS Harmonic scalpel compared to conventional haemostasis (knot and tie ligation) for thyroid surgery: a prospective randomized study
Haemostasis is crucial in thyroid surgery to avoid intraoperative and postoperative complications. In the present study, we evaluated the efficiency and the safety of Harmonic scalpel when compared to conventional suture ligation in open total thyroidectomy. We enrolled 265 patients who underwent to...
Autores principales: | Cannizzaro, Matteo Angelo, Bianco, Salvatore Lo, Borzì, Laura, Cavallaro, Andrea, Buffone, Antonino |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer International Publishing
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4218928/ https://www.ncbi.nlm.nih.gov/pubmed/25392807 http://dx.doi.org/10.1186/2193-1801-3-639 |
Ejemplares similares
-
Focus Harmonic Scalpel Compared to Conventional Haemostasis in Open Total Thyroidectomy: A Prospective Randomized Trial
por: Ferri, Emanuele, et al.
Publicado: (2011) -
Harmonic Scalpel versus Conventional Haemostasis in Neck Dissection: A Prospective Randomized Study
por: Ferri, Emanuele, et al.
Publicado: (2013) -
Total thyroidectomy: Conventional Suture Ligation technique versus sutureless techniques using Harmonic Scalpel or Maxium
por: Al-Dhahiry, Jawad Kadhim S., et al.
Publicado: (2015) -
FOCUS harmonic scalpel compared to conventional hemostasis in open total thyroidectomy - a prospective randomized study
por: Duan, Yun-fei, et al.
Publicado: (2013) -
A meta-analysis comparing the outcomes of LigaSure Small Jaw versus clamp-and-tie technique or Harmonic Focus Scalpel in thyroidectomy
por: Zhang, Lei, et al.
Publicado: (2017)