Acute Shunt Malfunction Caused by Percutaneous Endoscopic Gastrostomy without Shunt Infection
Percutaneous endoscopic gastrostomy tube placement is often performed in patients with a ventriculoperitoneal shunt and it has been accepted as a safe procedure. The authors report a case of a 50-year-old male who developed acute exacerbation of the hydrocephalus immediately after the percutaneous e...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Korean Neurosurgical Society
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4219198/ https://www.ncbi.nlm.nih.gov/pubmed/25371790 http://dx.doi.org/10.3340/jkns.2014.56.4.361 |
_version_ | 1782342552404361216 |
---|---|
author | Choi, Jingyu Ki, Seung Seog Park, Seoungwoo |
author_facet | Choi, Jingyu Ki, Seung Seog Park, Seoungwoo |
author_sort | Choi, Jingyu |
collection | PubMed |
description | Percutaneous endoscopic gastrostomy tube placement is often performed in patients with a ventriculoperitoneal shunt and it has been accepted as a safe procedure. The authors report a case of a 50-year-old male who developed acute exacerbation of the hydrocephalus immediately after the percutaneous endoscopic gastrostomy tube placement without any signs of shunt infection, which has not been reported until now. After revision of the intraperitoneal shunt catheter, the sizes of the intracranial ventricles were normalized. |
format | Online Article Text |
id | pubmed-4219198 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | The Korean Neurosurgical Society |
record_format | MEDLINE/PubMed |
spelling | pubmed-42191982014-11-04 Acute Shunt Malfunction Caused by Percutaneous Endoscopic Gastrostomy without Shunt Infection Choi, Jingyu Ki, Seung Seog Park, Seoungwoo J Korean Neurosurg Soc Case Report Percutaneous endoscopic gastrostomy tube placement is often performed in patients with a ventriculoperitoneal shunt and it has been accepted as a safe procedure. The authors report a case of a 50-year-old male who developed acute exacerbation of the hydrocephalus immediately after the percutaneous endoscopic gastrostomy tube placement without any signs of shunt infection, which has not been reported until now. After revision of the intraperitoneal shunt catheter, the sizes of the intracranial ventricles were normalized. The Korean Neurosurgical Society 2014-10 2014-10-31 /pmc/articles/PMC4219198/ /pubmed/25371790 http://dx.doi.org/10.3340/jkns.2014.56.4.361 Text en Copyright © 2014 The Korean Neurosurgical Society http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Case Report Choi, Jingyu Ki, Seung Seog Park, Seoungwoo Acute Shunt Malfunction Caused by Percutaneous Endoscopic Gastrostomy without Shunt Infection |
title | Acute Shunt Malfunction Caused by Percutaneous Endoscopic Gastrostomy without Shunt Infection |
title_full | Acute Shunt Malfunction Caused by Percutaneous Endoscopic Gastrostomy without Shunt Infection |
title_fullStr | Acute Shunt Malfunction Caused by Percutaneous Endoscopic Gastrostomy without Shunt Infection |
title_full_unstemmed | Acute Shunt Malfunction Caused by Percutaneous Endoscopic Gastrostomy without Shunt Infection |
title_short | Acute Shunt Malfunction Caused by Percutaneous Endoscopic Gastrostomy without Shunt Infection |
title_sort | acute shunt malfunction caused by percutaneous endoscopic gastrostomy without shunt infection |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4219198/ https://www.ncbi.nlm.nih.gov/pubmed/25371790 http://dx.doi.org/10.3340/jkns.2014.56.4.361 |
work_keys_str_mv | AT choijingyu acuteshuntmalfunctioncausedbypercutaneousendoscopicgastrostomywithoutshuntinfection AT kiseungseog acuteshuntmalfunctioncausedbypercutaneousendoscopicgastrostomywithoutshuntinfection AT parkseoungwoo acuteshuntmalfunctioncausedbypercutaneousendoscopicgastrostomywithoutshuntinfection |