Acute Shunt Malfunction Caused by Percutaneous Endoscopic Gastrostomy without Shunt Infection

Percutaneous endoscopic gastrostomy tube placement is often performed in patients with a ventriculoperitoneal shunt and it has been accepted as a safe procedure. The authors report a case of a 50-year-old male who developed acute exacerbation of the hydrocephalus immediately after the percutaneous e...

Descripción completa

Detalles Bibliográficos
Autores principales: Choi, Jingyu, Ki, Seung Seog, Park, Seoungwoo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Neurosurgical Society 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4219198/
https://www.ncbi.nlm.nih.gov/pubmed/25371790
http://dx.doi.org/10.3340/jkns.2014.56.4.361
_version_ 1782342552404361216
author Choi, Jingyu
Ki, Seung Seog
Park, Seoungwoo
author_facet Choi, Jingyu
Ki, Seung Seog
Park, Seoungwoo
author_sort Choi, Jingyu
collection PubMed
description Percutaneous endoscopic gastrostomy tube placement is often performed in patients with a ventriculoperitoneal shunt and it has been accepted as a safe procedure. The authors report a case of a 50-year-old male who developed acute exacerbation of the hydrocephalus immediately after the percutaneous endoscopic gastrostomy tube placement without any signs of shunt infection, which has not been reported until now. After revision of the intraperitoneal shunt catheter, the sizes of the intracranial ventricles were normalized.
format Online
Article
Text
id pubmed-4219198
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher The Korean Neurosurgical Society
record_format MEDLINE/PubMed
spelling pubmed-42191982014-11-04 Acute Shunt Malfunction Caused by Percutaneous Endoscopic Gastrostomy without Shunt Infection Choi, Jingyu Ki, Seung Seog Park, Seoungwoo J Korean Neurosurg Soc Case Report Percutaneous endoscopic gastrostomy tube placement is often performed in patients with a ventriculoperitoneal shunt and it has been accepted as a safe procedure. The authors report a case of a 50-year-old male who developed acute exacerbation of the hydrocephalus immediately after the percutaneous endoscopic gastrostomy tube placement without any signs of shunt infection, which has not been reported until now. After revision of the intraperitoneal shunt catheter, the sizes of the intracranial ventricles were normalized. The Korean Neurosurgical Society 2014-10 2014-10-31 /pmc/articles/PMC4219198/ /pubmed/25371790 http://dx.doi.org/10.3340/jkns.2014.56.4.361 Text en Copyright © 2014 The Korean Neurosurgical Society http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Case Report
Choi, Jingyu
Ki, Seung Seog
Park, Seoungwoo
Acute Shunt Malfunction Caused by Percutaneous Endoscopic Gastrostomy without Shunt Infection
title Acute Shunt Malfunction Caused by Percutaneous Endoscopic Gastrostomy without Shunt Infection
title_full Acute Shunt Malfunction Caused by Percutaneous Endoscopic Gastrostomy without Shunt Infection
title_fullStr Acute Shunt Malfunction Caused by Percutaneous Endoscopic Gastrostomy without Shunt Infection
title_full_unstemmed Acute Shunt Malfunction Caused by Percutaneous Endoscopic Gastrostomy without Shunt Infection
title_short Acute Shunt Malfunction Caused by Percutaneous Endoscopic Gastrostomy without Shunt Infection
title_sort acute shunt malfunction caused by percutaneous endoscopic gastrostomy without shunt infection
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4219198/
https://www.ncbi.nlm.nih.gov/pubmed/25371790
http://dx.doi.org/10.3340/jkns.2014.56.4.361
work_keys_str_mv AT choijingyu acuteshuntmalfunctioncausedbypercutaneousendoscopicgastrostomywithoutshuntinfection
AT kiseungseog acuteshuntmalfunctioncausedbypercutaneousendoscopicgastrostomywithoutshuntinfection
AT parkseoungwoo acuteshuntmalfunctioncausedbypercutaneousendoscopicgastrostomywithoutshuntinfection