Cargando…
Validation of a model-based measurement of the minimum insert thickness of knee prostheses: a retrieval study
INTRODUCTION: Wear of polyethylene inserts plays an important role in failure of total knee replacement and can be monitored in vivo by measuring the minimum joint space width in anteroposterior radiographs. The objective of this retrospective cross-sectional study was to compare the accuracy and pr...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
British Editorial Society of Bone and Joint Surgery
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4220171/ https://www.ncbi.nlm.nih.gov/pubmed/25278502 http://dx.doi.org/10.1302/2046-3758.310.2000304 |
_version_ | 1782342705940004864 |
---|---|
author | van IJsseldijk, E. A. Harman, M. K. Luetzner, J. Valstar, E. R. Stoel, B. C. Nelissen, R. G. H. H. Kaptein, B. L. |
author_facet | van IJsseldijk, E. A. Harman, M. K. Luetzner, J. Valstar, E. R. Stoel, B. C. Nelissen, R. G. H. H. Kaptein, B. L. |
author_sort | van IJsseldijk, E. A. |
collection | PubMed |
description | INTRODUCTION: Wear of polyethylene inserts plays an important role in failure of total knee replacement and can be monitored in vivo by measuring the minimum joint space width in anteroposterior radiographs. The objective of this retrospective cross-sectional study was to compare the accuracy and precision of a new model-based method with the conventional method by analysing the difference between the minimum joint space width measurements and the actual thickness of retrieved polyethylene tibial inserts. METHOD: Before revision, the minimum joint space width values and their locations on the insert were measured in 15 fully weight-bearing radiographs. These measurements were compared with the actual minimum thickness values and locations of the retrieved tibial inserts after revision. RESULTS: The mean error in the model-based minimum joint space width measurement was significantly smaller than the conventional method for medial condyles (0.50 vs 0.94 mm, p < 0.01) and for lateral condyles (0.06 vs 0.34 mm, p = 0.02). The precision (standard deviation of the error) of the methods was similar (0.84 vs 0.79 mm medially and both 0.46 mm laterally). The distance between the true minimum joint space width locations and the locations from the model-based measurements was less than 10 mm in the medial direction in 12 cases and less in the lateral direction in 13 cases. CONCLUSION: The model-based minimum joint space width measurement method is more accurate than the conventional measurement with the same precision. Cite this article: Bone Joint Res 2014;3:289–96 |
format | Online Article Text |
id | pubmed-4220171 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | British Editorial Society of Bone and Joint Surgery |
record_format | MEDLINE/PubMed |
spelling | pubmed-42201712014-11-07 Validation of a model-based measurement of the minimum insert thickness of knee prostheses: a retrieval study van IJsseldijk, E. A. Harman, M. K. Luetzner, J. Valstar, E. R. Stoel, B. C. Nelissen, R. G. H. H. Kaptein, B. L. Bone Joint Res Knee INTRODUCTION: Wear of polyethylene inserts plays an important role in failure of total knee replacement and can be monitored in vivo by measuring the minimum joint space width in anteroposterior radiographs. The objective of this retrospective cross-sectional study was to compare the accuracy and precision of a new model-based method with the conventional method by analysing the difference between the minimum joint space width measurements and the actual thickness of retrieved polyethylene tibial inserts. METHOD: Before revision, the minimum joint space width values and their locations on the insert were measured in 15 fully weight-bearing radiographs. These measurements were compared with the actual minimum thickness values and locations of the retrieved tibial inserts after revision. RESULTS: The mean error in the model-based minimum joint space width measurement was significantly smaller than the conventional method for medial condyles (0.50 vs 0.94 mm, p < 0.01) and for lateral condyles (0.06 vs 0.34 mm, p = 0.02). The precision (standard deviation of the error) of the methods was similar (0.84 vs 0.79 mm medially and both 0.46 mm laterally). The distance between the true minimum joint space width locations and the locations from the model-based measurements was less than 10 mm in the medial direction in 12 cases and less in the lateral direction in 13 cases. CONCLUSION: The model-based minimum joint space width measurement method is more accurate than the conventional measurement with the same precision. Cite this article: Bone Joint Res 2014;3:289–96 British Editorial Society of Bone and Joint Surgery 2014-10-01 /pmc/articles/PMC4220171/ /pubmed/25278502 http://dx.doi.org/10.1302/2046-3758.310.2000304 Text en ©2014 The British Editorial Society of Bone & Joint Surgery ©2014 The British Editorial Society of Bone & Joint Surgery. This is an open-access article distributed under the terms of the Creative Commons Attributions licence, which permits unrestricted use, distribution, and reproduction in any medium, but not for commercial gain, provided the original author and source are credited. |
spellingShingle | Knee van IJsseldijk, E. A. Harman, M. K. Luetzner, J. Valstar, E. R. Stoel, B. C. Nelissen, R. G. H. H. Kaptein, B. L. Validation of a model-based measurement of the minimum insert thickness of knee prostheses: a retrieval study |
title | Validation of a model-based measurement
of the minimum insert thickness of knee prostheses: a retrieval study |
title_full | Validation of a model-based measurement
of the minimum insert thickness of knee prostheses: a retrieval study |
title_fullStr | Validation of a model-based measurement
of the minimum insert thickness of knee prostheses: a retrieval study |
title_full_unstemmed | Validation of a model-based measurement
of the minimum insert thickness of knee prostheses: a retrieval study |
title_short | Validation of a model-based measurement
of the minimum insert thickness of knee prostheses: a retrieval study |
title_sort | validation of a model-based measurement
of the minimum insert thickness of knee prostheses: a retrieval study |
topic | Knee |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4220171/ https://www.ncbi.nlm.nih.gov/pubmed/25278502 http://dx.doi.org/10.1302/2046-3758.310.2000304 |
work_keys_str_mv | AT vanijsseldijkea validationofamodelbasedmeasurementoftheminimuminsertthicknessofkneeprosthesesaretrievalstudy AT harmanmk validationofamodelbasedmeasurementoftheminimuminsertthicknessofkneeprosthesesaretrievalstudy AT luetznerj validationofamodelbasedmeasurementoftheminimuminsertthicknessofkneeprosthesesaretrievalstudy AT valstarer validationofamodelbasedmeasurementoftheminimuminsertthicknessofkneeprosthesesaretrievalstudy AT stoelbc validationofamodelbasedmeasurementoftheminimuminsertthicknessofkneeprosthesesaretrievalstudy AT nelissenrghh validationofamodelbasedmeasurementoftheminimuminsertthicknessofkneeprosthesesaretrievalstudy AT kapteinbl validationofamodelbasedmeasurementoftheminimuminsertthicknessofkneeprosthesesaretrievalstudy |