Cargando…

An intraoperative device to restore femoral offset in total hip arthroplasty

BACKGROUND: Leg length discrepancy (LLD) after total hip arthroplasty (THA) can lead to unsatisfactory outcome. Our objective was to design and evaluate a simple and reliable intraoperative device (Length-offset Lever) to minimize leg length discrepancy. METHODS: This device was used in 51 patients...

Descripción completa

Detalles Bibliográficos
Autores principales: Xue, Enxing, Su, Zhen, Chen, Chengwang, Wong, Paul Kim Chiu, Wen, Hong, Zhang, Yu
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4223551/
https://www.ncbi.nlm.nih.gov/pubmed/25037492
http://dx.doi.org/10.1186/s13018-014-0058-7
_version_ 1782343215644409856
author Xue, Enxing
Su, Zhen
Chen, Chengwang
Wong, Paul Kim Chiu
Wen, Hong
Zhang, Yu
author_facet Xue, Enxing
Su, Zhen
Chen, Chengwang
Wong, Paul Kim Chiu
Wen, Hong
Zhang, Yu
author_sort Xue, Enxing
collection PubMed
description BACKGROUND: Leg length discrepancy (LLD) after total hip arthroplasty (THA) can lead to unsatisfactory outcome. Our objective was to design and evaluate a simple and reliable intraoperative device (Length-offset Lever) to minimize leg length discrepancy. METHODS: This device was used in 51 patients undergoing primary total hip replacements. The leg length discrepancy was measured pre- and postoperatively based on plain radiographs. RESULTS: Preoperative radiographic leg length discrepancy averaged 13.5 ± 6.2 mm. Leg length discrepancy showed significant improvement, with a postoperative average of 4.1 ± 2.3 mm (p < 0.0001). There were no complications associated with this device. CONCLUSIONS: The ‘Length-offset Lever’ is a useful intraoperative tool to restore anatomic femoral offset and height of femoral head.
format Online
Article
Text
id pubmed-4223551
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-42235512014-11-08 An intraoperative device to restore femoral offset in total hip arthroplasty Xue, Enxing Su, Zhen Chen, Chengwang Wong, Paul Kim Chiu Wen, Hong Zhang, Yu J Orthop Surg Res Technical Note BACKGROUND: Leg length discrepancy (LLD) after total hip arthroplasty (THA) can lead to unsatisfactory outcome. Our objective was to design and evaluate a simple and reliable intraoperative device (Length-offset Lever) to minimize leg length discrepancy. METHODS: This device was used in 51 patients undergoing primary total hip replacements. The leg length discrepancy was measured pre- and postoperatively based on plain radiographs. RESULTS: Preoperative radiographic leg length discrepancy averaged 13.5 ± 6.2 mm. Leg length discrepancy showed significant improvement, with a postoperative average of 4.1 ± 2.3 mm (p < 0.0001). There were no complications associated with this device. CONCLUSIONS: The ‘Length-offset Lever’ is a useful intraoperative tool to restore anatomic femoral offset and height of femoral head. BioMed Central 2014-07-19 /pmc/articles/PMC4223551/ /pubmed/25037492 http://dx.doi.org/10.1186/s13018-014-0058-7 Text en Copyright © 2014 Xue et al.; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Technical Note
Xue, Enxing
Su, Zhen
Chen, Chengwang
Wong, Paul Kim Chiu
Wen, Hong
Zhang, Yu
An intraoperative device to restore femoral offset in total hip arthroplasty
title An intraoperative device to restore femoral offset in total hip arthroplasty
title_full An intraoperative device to restore femoral offset in total hip arthroplasty
title_fullStr An intraoperative device to restore femoral offset in total hip arthroplasty
title_full_unstemmed An intraoperative device to restore femoral offset in total hip arthroplasty
title_short An intraoperative device to restore femoral offset in total hip arthroplasty
title_sort intraoperative device to restore femoral offset in total hip arthroplasty
topic Technical Note
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4223551/
https://www.ncbi.nlm.nih.gov/pubmed/25037492
http://dx.doi.org/10.1186/s13018-014-0058-7
work_keys_str_mv AT xueenxing anintraoperativedevicetorestorefemoraloffsetintotalhiparthroplasty
AT suzhen anintraoperativedevicetorestorefemoraloffsetintotalhiparthroplasty
AT chenchengwang anintraoperativedevicetorestorefemoraloffsetintotalhiparthroplasty
AT wongpaulkimchiu anintraoperativedevicetorestorefemoraloffsetintotalhiparthroplasty
AT wenhong anintraoperativedevicetorestorefemoraloffsetintotalhiparthroplasty
AT zhangyu anintraoperativedevicetorestorefemoraloffsetintotalhiparthroplasty
AT xueenxing intraoperativedevicetorestorefemoraloffsetintotalhiparthroplasty
AT suzhen intraoperativedevicetorestorefemoraloffsetintotalhiparthroplasty
AT chenchengwang intraoperativedevicetorestorefemoraloffsetintotalhiparthroplasty
AT wongpaulkimchiu intraoperativedevicetorestorefemoraloffsetintotalhiparthroplasty
AT wenhong intraoperativedevicetorestorefemoraloffsetintotalhiparthroplasty
AT zhangyu intraoperativedevicetorestorefemoraloffsetintotalhiparthroplasty