Cargando…
An intraoperative device to restore femoral offset in total hip arthroplasty
BACKGROUND: Leg length discrepancy (LLD) after total hip arthroplasty (THA) can lead to unsatisfactory outcome. Our objective was to design and evaluate a simple and reliable intraoperative device (Length-offset Lever) to minimize leg length discrepancy. METHODS: This device was used in 51 patients...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4223551/ https://www.ncbi.nlm.nih.gov/pubmed/25037492 http://dx.doi.org/10.1186/s13018-014-0058-7 |
_version_ | 1782343215644409856 |
---|---|
author | Xue, Enxing Su, Zhen Chen, Chengwang Wong, Paul Kim Chiu Wen, Hong Zhang, Yu |
author_facet | Xue, Enxing Su, Zhen Chen, Chengwang Wong, Paul Kim Chiu Wen, Hong Zhang, Yu |
author_sort | Xue, Enxing |
collection | PubMed |
description | BACKGROUND: Leg length discrepancy (LLD) after total hip arthroplasty (THA) can lead to unsatisfactory outcome. Our objective was to design and evaluate a simple and reliable intraoperative device (Length-offset Lever) to minimize leg length discrepancy. METHODS: This device was used in 51 patients undergoing primary total hip replacements. The leg length discrepancy was measured pre- and postoperatively based on plain radiographs. RESULTS: Preoperative radiographic leg length discrepancy averaged 13.5 ± 6.2 mm. Leg length discrepancy showed significant improvement, with a postoperative average of 4.1 ± 2.3 mm (p < 0.0001). There were no complications associated with this device. CONCLUSIONS: The ‘Length-offset Lever’ is a useful intraoperative tool to restore anatomic femoral offset and height of femoral head. |
format | Online Article Text |
id | pubmed-4223551 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-42235512014-11-08 An intraoperative device to restore femoral offset in total hip arthroplasty Xue, Enxing Su, Zhen Chen, Chengwang Wong, Paul Kim Chiu Wen, Hong Zhang, Yu J Orthop Surg Res Technical Note BACKGROUND: Leg length discrepancy (LLD) after total hip arthroplasty (THA) can lead to unsatisfactory outcome. Our objective was to design and evaluate a simple and reliable intraoperative device (Length-offset Lever) to minimize leg length discrepancy. METHODS: This device was used in 51 patients undergoing primary total hip replacements. The leg length discrepancy was measured pre- and postoperatively based on plain radiographs. RESULTS: Preoperative radiographic leg length discrepancy averaged 13.5 ± 6.2 mm. Leg length discrepancy showed significant improvement, with a postoperative average of 4.1 ± 2.3 mm (p < 0.0001). There were no complications associated with this device. CONCLUSIONS: The ‘Length-offset Lever’ is a useful intraoperative tool to restore anatomic femoral offset and height of femoral head. BioMed Central 2014-07-19 /pmc/articles/PMC4223551/ /pubmed/25037492 http://dx.doi.org/10.1186/s13018-014-0058-7 Text en Copyright © 2014 Xue et al.; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Technical Note Xue, Enxing Su, Zhen Chen, Chengwang Wong, Paul Kim Chiu Wen, Hong Zhang, Yu An intraoperative device to restore femoral offset in total hip arthroplasty |
title | An intraoperative device to restore femoral offset in total hip arthroplasty |
title_full | An intraoperative device to restore femoral offset in total hip arthroplasty |
title_fullStr | An intraoperative device to restore femoral offset in total hip arthroplasty |
title_full_unstemmed | An intraoperative device to restore femoral offset in total hip arthroplasty |
title_short | An intraoperative device to restore femoral offset in total hip arthroplasty |
title_sort | intraoperative device to restore femoral offset in total hip arthroplasty |
topic | Technical Note |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4223551/ https://www.ncbi.nlm.nih.gov/pubmed/25037492 http://dx.doi.org/10.1186/s13018-014-0058-7 |
work_keys_str_mv | AT xueenxing anintraoperativedevicetorestorefemoraloffsetintotalhiparthroplasty AT suzhen anintraoperativedevicetorestorefemoraloffsetintotalhiparthroplasty AT chenchengwang anintraoperativedevicetorestorefemoraloffsetintotalhiparthroplasty AT wongpaulkimchiu anintraoperativedevicetorestorefemoraloffsetintotalhiparthroplasty AT wenhong anintraoperativedevicetorestorefemoraloffsetintotalhiparthroplasty AT zhangyu anintraoperativedevicetorestorefemoraloffsetintotalhiparthroplasty AT xueenxing intraoperativedevicetorestorefemoraloffsetintotalhiparthroplasty AT suzhen intraoperativedevicetorestorefemoraloffsetintotalhiparthroplasty AT chenchengwang intraoperativedevicetorestorefemoraloffsetintotalhiparthroplasty AT wongpaulkimchiu intraoperativedevicetorestorefemoraloffsetintotalhiparthroplasty AT wenhong intraoperativedevicetorestorefemoraloffsetintotalhiparthroplasty AT zhangyu intraoperativedevicetorestorefemoraloffsetintotalhiparthroplasty |