Cargando…

Resistance of three implant-abutment interfaces to fatigue testing

The design and retentive properties of implant-abutment connectors affect the mechanical resistance of implants. A number of studies have been carried out to compare the efficacy of connecting mechanisms between abutment and fixture. OBJECTIVES: The aims of this study were: 1) to compare 3 implant-a...

Descripción completa

Detalles Bibliográficos
Autores principales: RIBEIRO, Cleide Gisele, MAIA, Maria Luiza Cabral, SCHERRER, Susanne S., CARDOSO, Antonio Carlos, WISKOTT, H. W. Anselm
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Faculdade de Odontologia de Bauru da Universidade de São Paulo 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4223795/
https://www.ncbi.nlm.nih.gov/pubmed/21710094
http://dx.doi.org/10.1590/S1678-77572011005000018
_version_ 1782343263786631168
author RIBEIRO, Cleide Gisele
MAIA, Maria Luiza Cabral
SCHERRER, Susanne S.
CARDOSO, Antonio Carlos
WISKOTT, H. W. Anselm
author_facet RIBEIRO, Cleide Gisele
MAIA, Maria Luiza Cabral
SCHERRER, Susanne S.
CARDOSO, Antonio Carlos
WISKOTT, H. W. Anselm
author_sort RIBEIRO, Cleide Gisele
collection PubMed
description The design and retentive properties of implant-abutment connectors affect the mechanical resistance of implants. A number of studies have been carried out to compare the efficacy of connecting mechanisms between abutment and fixture. OBJECTIVES: The aims of this study were: 1) to compare 3 implant-abutment interfaces (external hexagon, internal hexagon and cone-in-cone) regarding the fatigue resistance of the prosthetic screw, 2) to evaluate the corresponding mode of failure, and 3) to compare the results of this study with data obtained in previous studies on Nobel Biocare and Straumann connectors. MATERIALS AND METHODS: In order to duplicate the alternating and multivectorial intraoral loading pattern, the specimens were submitted to the rotating cantilever beam test. The implants, abutments and restoration analogs were spun around their longitudinal axes while a perpendicular force was applied to the external end. The objective was to determine the force level at which 50% of the specimens survived 10(6) load cycles. The mean force levels at which 50% failed and the corresponding 95% confidence intervals were determined using the staircase procedure. RESULTS: The external hexagon interface presented better than the cone-in-cone and internal hexagon interfaces. There was no significant difference between the cone-in-cone and internal hex interfaces. CONCLUSION: Although internal connections present a more favorable design, this study did not show any advantage in terms of strength. The external hexagon connector used in this study yielded similar results to those obtained in a previous study with Nobel Biocare and Straumann systems. However, the internal connections (cone-in-cone and internal hexagon) were mechanically inferior compared to previous results.
format Online
Article
Text
id pubmed-4223795
institution National Center for Biotechnology Information
language English
publishDate 2011
publisher Faculdade de Odontologia de Bauru da Universidade de São Paulo
record_format MEDLINE/PubMed
spelling pubmed-42237952014-11-12 Resistance of three implant-abutment interfaces to fatigue testing RIBEIRO, Cleide Gisele MAIA, Maria Luiza Cabral SCHERRER, Susanne S. CARDOSO, Antonio Carlos WISKOTT, H. W. Anselm J Appl Oral Sci Original Articles The design and retentive properties of implant-abutment connectors affect the mechanical resistance of implants. A number of studies have been carried out to compare the efficacy of connecting mechanisms between abutment and fixture. OBJECTIVES: The aims of this study were: 1) to compare 3 implant-abutment interfaces (external hexagon, internal hexagon and cone-in-cone) regarding the fatigue resistance of the prosthetic screw, 2) to evaluate the corresponding mode of failure, and 3) to compare the results of this study with data obtained in previous studies on Nobel Biocare and Straumann connectors. MATERIALS AND METHODS: In order to duplicate the alternating and multivectorial intraoral loading pattern, the specimens were submitted to the rotating cantilever beam test. The implants, abutments and restoration analogs were spun around their longitudinal axes while a perpendicular force was applied to the external end. The objective was to determine the force level at which 50% of the specimens survived 10(6) load cycles. The mean force levels at which 50% failed and the corresponding 95% confidence intervals were determined using the staircase procedure. RESULTS: The external hexagon interface presented better than the cone-in-cone and internal hexagon interfaces. There was no significant difference between the cone-in-cone and internal hex interfaces. CONCLUSION: Although internal connections present a more favorable design, this study did not show any advantage in terms of strength. The external hexagon connector used in this study yielded similar results to those obtained in a previous study with Nobel Biocare and Straumann systems. However, the internal connections (cone-in-cone and internal hexagon) were mechanically inferior compared to previous results. Faculdade de Odontologia de Bauru da Universidade de São Paulo 2011 /pmc/articles/PMC4223795/ /pubmed/21710094 http://dx.doi.org/10.1590/S1678-77572011005000018 Text en http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Articles
RIBEIRO, Cleide Gisele
MAIA, Maria Luiza Cabral
SCHERRER, Susanne S.
CARDOSO, Antonio Carlos
WISKOTT, H. W. Anselm
Resistance of three implant-abutment interfaces to fatigue testing
title Resistance of three implant-abutment interfaces to fatigue testing
title_full Resistance of three implant-abutment interfaces to fatigue testing
title_fullStr Resistance of three implant-abutment interfaces to fatigue testing
title_full_unstemmed Resistance of three implant-abutment interfaces to fatigue testing
title_short Resistance of three implant-abutment interfaces to fatigue testing
title_sort resistance of three implant-abutment interfaces to fatigue testing
topic Original Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4223795/
https://www.ncbi.nlm.nih.gov/pubmed/21710094
http://dx.doi.org/10.1590/S1678-77572011005000018
work_keys_str_mv AT ribeirocleidegisele resistanceofthreeimplantabutmentinterfacestofatiguetesting
AT maiamarialuizacabral resistanceofthreeimplantabutmentinterfacestofatiguetesting
AT scherrersusannes resistanceofthreeimplantabutmentinterfacestofatiguetesting
AT cardosoantoniocarlos resistanceofthreeimplantabutmentinterfacestofatiguetesting
AT wiskotthwanselm resistanceofthreeimplantabutmentinterfacestofatiguetesting