Cargando…

Service impact of a change in HIV-1 viral load quantification assay

INTRODUCTION: Due to discontinuation of the Siemens Versant HIV-1 RNA (bDNA) assay in the UK, our laboratory switched to the Roche Cobas Ampliprep/Taqman HIV-1 viral load (VL) assay (Roche) in April 2013. This assay has a lower cut-off of 20 RNA copies/mL (compared with <50 for the Siemens assay)...

Descripción completa

Detalles Bibliográficos
Autores principales: Tipple, Craig, Oomeer, Soonita, Dosekun, Olamide, Mackie, Nicola
Formato: Online Artículo Texto
Lenguaje:English
Publicado: International AIDS Society 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4225297/
https://www.ncbi.nlm.nih.gov/pubmed/25397427
http://dx.doi.org/10.7448/IAS.17.4.19677
_version_ 1782343477319696384
author Tipple, Craig
Oomeer, Soonita
Dosekun, Olamide
Mackie, Nicola
author_facet Tipple, Craig
Oomeer, Soonita
Dosekun, Olamide
Mackie, Nicola
author_sort Tipple, Craig
collection PubMed
description INTRODUCTION: Due to discontinuation of the Siemens Versant HIV-1 RNA (bDNA) assay in the UK, our laboratory switched to the Roche Cobas Ampliprep/Taqman HIV-1 viral load (VL) assay (Roche) in April 2013. This assay has a lower cut-off of 20 RNA copies/mL (compared with <50 for the Siemens assay). Our laboratory demonstrated previously that a significant proportion (18%) of patients undetectable using bDNA HIV-1 RNA quantification exhibited low level viraemia (LLV) using the new assay. Local guidelines recommend that patients stable on therapy receive twice-yearly VLs. We evaluated the impact of the introduction of the new assay on our clinical service. METHODS: A retrospective cohort analysis of treated patients with stable undetectable VL by bDNA (<50 copies/mL) followed by ≥ one low-level (<400 copies/mL) VL with the Roche assay. Demographic data were collected in addition to frequency of VL testing and genotypic resistance assays. Referrals to virtual clinic (VC) were recorded. Patients were identified using laboratory data and information collected from electronic patient records. Results were analyzed with SPSS v18. RESULTS: One hundred and ninety patients were included. Demographics: 79.5% male; 60.6% homosexual; mean age of 46 years. Duration on stable treatment was 46.35 (std. dev. 38.15) months. Current treatment regimens were 43.3% PI-based; 43.3% NNRTI-based and 13.7% other. Patients were stratified into VL 20–49 copies/mL (n=109); VL 50–199 copies/mL (n=71) and VL 200–399 copies/mL (n=10). In total, there were 471 VLs measured of which 274 were additional as a result of the assay switch. This resulted in six HIV-1 genotype requests and 16 VC discussions (Table 1). Longer duration on HAART was associated with reduced frequency of VL testing. The relative risk of ongoing detectability according to drug class are: PI 1.62 (95% CI 1.18–2.21); NNRTI 0.507 (95% CI 0.30–0.85) and other 1.09 (95% CI 0.48–2.43). CONCLUSIONS: Changes in assay can result in difficulties in interpretation of patient results. The assay switch in our service had significant impact on patient and staff time and cost with an increase in patient recalls; increased frequency of VL measurement, genotypes and discussions in VC. Choice of assay is paramount to running an efficient and cost-effective clinical service.
format Online
Article
Text
id pubmed-4225297
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher International AIDS Society
record_format MEDLINE/PubMed
spelling pubmed-42252972014-11-12 Service impact of a change in HIV-1 viral load quantification assay Tipple, Craig Oomeer, Soonita Dosekun, Olamide Mackie, Nicola J Int AIDS Soc Poster Sessions – Abstract P145 INTRODUCTION: Due to discontinuation of the Siemens Versant HIV-1 RNA (bDNA) assay in the UK, our laboratory switched to the Roche Cobas Ampliprep/Taqman HIV-1 viral load (VL) assay (Roche) in April 2013. This assay has a lower cut-off of 20 RNA copies/mL (compared with <50 for the Siemens assay). Our laboratory demonstrated previously that a significant proportion (18%) of patients undetectable using bDNA HIV-1 RNA quantification exhibited low level viraemia (LLV) using the new assay. Local guidelines recommend that patients stable on therapy receive twice-yearly VLs. We evaluated the impact of the introduction of the new assay on our clinical service. METHODS: A retrospective cohort analysis of treated patients with stable undetectable VL by bDNA (<50 copies/mL) followed by ≥ one low-level (<400 copies/mL) VL with the Roche assay. Demographic data were collected in addition to frequency of VL testing and genotypic resistance assays. Referrals to virtual clinic (VC) were recorded. Patients were identified using laboratory data and information collected from electronic patient records. Results were analyzed with SPSS v18. RESULTS: One hundred and ninety patients were included. Demographics: 79.5% male; 60.6% homosexual; mean age of 46 years. Duration on stable treatment was 46.35 (std. dev. 38.15) months. Current treatment regimens were 43.3% PI-based; 43.3% NNRTI-based and 13.7% other. Patients were stratified into VL 20–49 copies/mL (n=109); VL 50–199 copies/mL (n=71) and VL 200–399 copies/mL (n=10). In total, there were 471 VLs measured of which 274 were additional as a result of the assay switch. This resulted in six HIV-1 genotype requests and 16 VC discussions (Table 1). Longer duration on HAART was associated with reduced frequency of VL testing. The relative risk of ongoing detectability according to drug class are: PI 1.62 (95% CI 1.18–2.21); NNRTI 0.507 (95% CI 0.30–0.85) and other 1.09 (95% CI 0.48–2.43). CONCLUSIONS: Changes in assay can result in difficulties in interpretation of patient results. The assay switch in our service had significant impact on patient and staff time and cost with an increase in patient recalls; increased frequency of VL measurement, genotypes and discussions in VC. Choice of assay is paramount to running an efficient and cost-effective clinical service. International AIDS Society 2014-11-02 /pmc/articles/PMC4225297/ /pubmed/25397427 http://dx.doi.org/10.7448/IAS.17.4.19677 Text en © 2014 Tipple C et al; licensee International AIDS Society http://creativecommons.org/licenses/by/3.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Poster Sessions – Abstract P145
Tipple, Craig
Oomeer, Soonita
Dosekun, Olamide
Mackie, Nicola
Service impact of a change in HIV-1 viral load quantification assay
title Service impact of a change in HIV-1 viral load quantification assay
title_full Service impact of a change in HIV-1 viral load quantification assay
title_fullStr Service impact of a change in HIV-1 viral load quantification assay
title_full_unstemmed Service impact of a change in HIV-1 viral load quantification assay
title_short Service impact of a change in HIV-1 viral load quantification assay
title_sort service impact of a change in hiv-1 viral load quantification assay
topic Poster Sessions – Abstract P145
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4225297/
https://www.ncbi.nlm.nih.gov/pubmed/25397427
http://dx.doi.org/10.7448/IAS.17.4.19677
work_keys_str_mv AT tipplecraig serviceimpactofachangeinhiv1viralloadquantificationassay
AT oomeersoonita serviceimpactofachangeinhiv1viralloadquantificationassay
AT dosekunolamide serviceimpactofachangeinhiv1viralloadquantificationassay
AT mackienicola serviceimpactofachangeinhiv1viralloadquantificationassay