Heart rate variability analysis using robust period detection
OBJECTIVE: Heart rate variability (HRV) analysis, which is an important tool for activity assessment of the cardiac autonomic nervous system, very often includes the estimation of power spectra for series of interbeat intervals (IBI). Ectopic beats and artifacts have a destructive effect on the stan...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4228159/ https://www.ncbi.nlm.nih.gov/pubmed/25248280 http://dx.doi.org/10.1186/1475-925X-13-138 |
_version_ | 1782343923259146240 |
---|---|
author | Skotte, Jørgen H Kristiansen, Jesper |
author_facet | Skotte, Jørgen H Kristiansen, Jesper |
author_sort | Skotte, Jørgen H |
collection | PubMed |
description | OBJECTIVE: Heart rate variability (HRV) analysis, which is an important tool for activity assessment of the cardiac autonomic nervous system, very often includes the estimation of power spectra for series of interbeat intervals (IBI). Ectopic beats and artifacts have a destructive effect on the standard methods (Fourier transform, FFT) for frequency analysis. This study investigates an alternative method for calculation of the periodogram using a robust period detection (RPD). METHOD: Error free IBI series of 5 minutes for 221 subjects during one day were artificially distorted by randomly changing IBI values by ±15-40%. The low to high frequency rate (LF/HF) were calculated from periodograms estimated by the FFT, RPD and Lomb (LSP) methods for both error free and distorted series and for series with removed beats. Log transformed LF/HF values for series with distorted/removed beats were compared to undistorted values by linear regression. RESULTS: For series with 10% of distorted IBI values the regression analysis between distorted and undistorted series showed a goodness of fit, coefficient and intercept of 0.98, 0.94 and 0.02, respectively. In comparison, the values of these parameters were (0.34, 0.46, -1.61) and (0.28, 0.42,-1.32) for the FFT and LSP methods, respectively. Similarly, the comparison between series with removed and undistorted beats yielded goodness of fit, coefficient and intercept of (0.98, 0.96, -0.01), (0.93, 0.78, -0.02) and (0.98, 0.95, 0.19) for RPD, FFT and LSP, respectively. CONCLUSION: The RPD method demonstrated superior performance compared to the FFT and LSP method by estimation of power spectral characteristics for HRV analysis. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1186/1475-925X-13-138) contains supplementary material, which is available to authorized users. |
format | Online Article Text |
id | pubmed-4228159 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-42281592014-11-13 Heart rate variability analysis using robust period detection Skotte, Jørgen H Kristiansen, Jesper Biomed Eng Online Research OBJECTIVE: Heart rate variability (HRV) analysis, which is an important tool for activity assessment of the cardiac autonomic nervous system, very often includes the estimation of power spectra for series of interbeat intervals (IBI). Ectopic beats and artifacts have a destructive effect on the standard methods (Fourier transform, FFT) for frequency analysis. This study investigates an alternative method for calculation of the periodogram using a robust period detection (RPD). METHOD: Error free IBI series of 5 minutes for 221 subjects during one day were artificially distorted by randomly changing IBI values by ±15-40%. The low to high frequency rate (LF/HF) were calculated from periodograms estimated by the FFT, RPD and Lomb (LSP) methods for both error free and distorted series and for series with removed beats. Log transformed LF/HF values for series with distorted/removed beats were compared to undistorted values by linear regression. RESULTS: For series with 10% of distorted IBI values the regression analysis between distorted and undistorted series showed a goodness of fit, coefficient and intercept of 0.98, 0.94 and 0.02, respectively. In comparison, the values of these parameters were (0.34, 0.46, -1.61) and (0.28, 0.42,-1.32) for the FFT and LSP methods, respectively. Similarly, the comparison between series with removed and undistorted beats yielded goodness of fit, coefficient and intercept of (0.98, 0.96, -0.01), (0.93, 0.78, -0.02) and (0.98, 0.95, 0.19) for RPD, FFT and LSP, respectively. CONCLUSION: The RPD method demonstrated superior performance compared to the FFT and LSP method by estimation of power spectral characteristics for HRV analysis. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1186/1475-925X-13-138) contains supplementary material, which is available to authorized users. BioMed Central 2014-09-23 /pmc/articles/PMC4228159/ /pubmed/25248280 http://dx.doi.org/10.1186/1475-925X-13-138 Text en © Skotte and Kristiansen; licensee BioMed Central Ltd. 2014 This article is published under license to BioMed Central Ltd. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Research Skotte, Jørgen H Kristiansen, Jesper Heart rate variability analysis using robust period detection |
title | Heart rate variability analysis using robust period detection |
title_full | Heart rate variability analysis using robust period detection |
title_fullStr | Heart rate variability analysis using robust period detection |
title_full_unstemmed | Heart rate variability analysis using robust period detection |
title_short | Heart rate variability analysis using robust period detection |
title_sort | heart rate variability analysis using robust period detection |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4228159/ https://www.ncbi.nlm.nih.gov/pubmed/25248280 http://dx.doi.org/10.1186/1475-925X-13-138 |
work_keys_str_mv | AT skottejørgenh heartratevariabilityanalysisusingrobustperioddetection AT kristiansenjesper heartratevariabilityanalysisusingrobustperioddetection |