Cargando…

Performance of a HRP-2/pLDH based rapid diagnostic test at the Bangladesh-India-Myanmar border areas for diagnosis of clinical malaria

BACKGROUND: The rapid diagnostic test (RDT) has been adopted in contemporary malaria control and management programmes around the world as it represents a fast and apt alternative for malaria diagnosis in a resource-limited setting. This study assessed the performance of a HRP-2/pLDH based RDT (Para...

Descripción completa

Detalles Bibliográficos
Autores principales: Elahi, Rubayet, Mohon, Abu Naser, Khan, Wasif A, Haque, Rashidul, Alam, Mohammad Shafiul
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4228469/
https://www.ncbi.nlm.nih.gov/pubmed/24172045
http://dx.doi.org/10.1186/1475-2875-12-378
Descripción
Sumario:BACKGROUND: The rapid diagnostic test (RDT) has been adopted in contemporary malaria control and management programmes around the world as it represents a fast and apt alternative for malaria diagnosis in a resource-limited setting. This study assessed the performance of a HRP-2/pLDH based RDT (Parascreen® Pan/Pf) in a laboratory setting utilizing clinical samples obtained from the field. METHODS: Whole blood samples were obtained from febrile patients referred for malaria diagnosis by clinicians from two different Upazila Health Complexes (UHCs) located near the Bangladesh-India and Bangladesh-Myanmar border where malaria is endemic. RDT was performed on archived samples and sensitivity and specificity evaluated with expert microscopy (EM) and quantitative PCR (qPCR). RESULTS: A total of 327 clinical samples were made available for the study, of which 153 were Plasmodium falciparum-positive and 54 were Plasmodium vivax-positive. In comparison with EM, for P. falciparum malaria, the RDT had sensitivity: 96.0% (95% CI, 91.2-98.3) and specificity: 98.2% (95% CI, 94.6-99.5) and for P. vivax, sensitivity: 90.7% (95% CI, 78.9-96.5) and specificity: 98.9% (95% CI, 96.5-99.7). Comparison with qPCR showed, for P. falciparum malaria, sensitivity: 95.4% (95% CI, 90.5-98.0) and specificity: 98.8% (95% CI, 95.4-99.7) and for P. vivax malaria, sensitivity: 89.0% (95% CI,77.0-95.4) and specificity: 98.8% (95% CI, 96.5-99.7). Sensitivity varied according to different parasitaemia for falciparum and vivax malaria diagnosis. CONCLUSION: Parascreen® Pan/Pf Rapid test for malaria showed acceptable sensitivity and specificity in border belt endemic areas of Bangladesh when compared with EM and qPCR.