Cargando…
Geometric accuracy of 3D coordinates of the Leksell stereotactic skull frame in 1.5 Tesla- and 3.0 Tesla-magnetic resonance imaging: a comparison of three different fixation screw materials
We assessed the geometric distortion of 1.5-Tesla (T) and 3.0-T magnetic resonance (MR) images with the Leksell skull frame system using three types of cranial quick fixation screws (QFSs) of different materials—aluminum, aluminum with tungsten tip, and titanium—for skull frame fixation. Two kinds o...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Oxford University Press
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4229929/ https://www.ncbi.nlm.nih.gov/pubmed/25034732 http://dx.doi.org/10.1093/jrr/rru064 |
_version_ | 1782344193611399168 |
---|---|
author | Nakazawa, Hisato Mori, Yoshimasa Yamamuro, Osamu Komori, Masataka Shibamoto, Yuta Uchiyama, Yukio Tsugawa, Takahiko Hagiwara, Masahiro |
author_facet | Nakazawa, Hisato Mori, Yoshimasa Yamamuro, Osamu Komori, Masataka Shibamoto, Yuta Uchiyama, Yukio Tsugawa, Takahiko Hagiwara, Masahiro |
author_sort | Nakazawa, Hisato |
collection | PubMed |
description | We assessed the geometric distortion of 1.5-Tesla (T) and 3.0-T magnetic resonance (MR) images with the Leksell skull frame system using three types of cranial quick fixation screws (QFSs) of different materials—aluminum, aluminum with tungsten tip, and titanium—for skull frame fixation. Two kinds of acrylic phantoms were placed on a Leksell skull frame using the three types of screws, and were scanned with computed tomography (CT), 1.5-T MR imaging and 3.0-T MR imaging. The 3D coordinates for both strengths of MR imaging were compared with those for CT. The deviations of the measured coordinates at selected points (x = 50, 100 and 150; y = 50, 100 and 150) were indicated on different axial planes (z = 50, 75, 100, 125 and 150). The errors of coordinates with QFSs of aluminum, tungsten-tipped aluminum, and titanium were <1.0, 1.0 and 2.0 mm in the entire treatable area, respectively, with 1.5 T. In the 3.0-T field, the errors with aluminum QFSs were <1.0 mm only around the center, while the errors with tungsten-tipped aluminum and titanium were >2.0 mm in most positions. The geometric accuracy of the Leksell skull frame system with 1.5-T MR imaging was high and valid for clinical use. However, the geometric errors with 3.0-T MR imaging were larger than those of 1.5-T MR imaging and were acceptable only with aluminum QFSs, and then only around the central region. |
format | Online Article Text |
id | pubmed-4229929 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | Oxford University Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-42299292014-11-21 Geometric accuracy of 3D coordinates of the Leksell stereotactic skull frame in 1.5 Tesla- and 3.0 Tesla-magnetic resonance imaging: a comparison of three different fixation screw materials Nakazawa, Hisato Mori, Yoshimasa Yamamuro, Osamu Komori, Masataka Shibamoto, Yuta Uchiyama, Yukio Tsugawa, Takahiko Hagiwara, Masahiro J Radiat Res Technology We assessed the geometric distortion of 1.5-Tesla (T) and 3.0-T magnetic resonance (MR) images with the Leksell skull frame system using three types of cranial quick fixation screws (QFSs) of different materials—aluminum, aluminum with tungsten tip, and titanium—for skull frame fixation. Two kinds of acrylic phantoms were placed on a Leksell skull frame using the three types of screws, and were scanned with computed tomography (CT), 1.5-T MR imaging and 3.0-T MR imaging. The 3D coordinates for both strengths of MR imaging were compared with those for CT. The deviations of the measured coordinates at selected points (x = 50, 100 and 150; y = 50, 100 and 150) were indicated on different axial planes (z = 50, 75, 100, 125 and 150). The errors of coordinates with QFSs of aluminum, tungsten-tipped aluminum, and titanium were <1.0, 1.0 and 2.0 mm in the entire treatable area, respectively, with 1.5 T. In the 3.0-T field, the errors with aluminum QFSs were <1.0 mm only around the center, while the errors with tungsten-tipped aluminum and titanium were >2.0 mm in most positions. The geometric accuracy of the Leksell skull frame system with 1.5-T MR imaging was high and valid for clinical use. However, the geometric errors with 3.0-T MR imaging were larger than those of 1.5-T MR imaging and were acceptable only with aluminum QFSs, and then only around the central region. Oxford University Press 2014-11 2014-07-17 /pmc/articles/PMC4229929/ /pubmed/25034732 http://dx.doi.org/10.1093/jrr/rru064 Text en © The Author 2014. Published by Oxford University Press on behalf of The Japan Radiation Research Society and Japanese Society for Radiation Oncology. http://creativecommons.org/licenses/by/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted reuse, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Technology Nakazawa, Hisato Mori, Yoshimasa Yamamuro, Osamu Komori, Masataka Shibamoto, Yuta Uchiyama, Yukio Tsugawa, Takahiko Hagiwara, Masahiro Geometric accuracy of 3D coordinates of the Leksell stereotactic skull frame in 1.5 Tesla- and 3.0 Tesla-magnetic resonance imaging: a comparison of three different fixation screw materials |
title | Geometric accuracy of 3D coordinates of the Leksell stereotactic skull frame in 1.5 Tesla- and 3.0 Tesla-magnetic resonance imaging: a comparison of three different fixation screw materials |
title_full | Geometric accuracy of 3D coordinates of the Leksell stereotactic skull frame in 1.5 Tesla- and 3.0 Tesla-magnetic resonance imaging: a comparison of three different fixation screw materials |
title_fullStr | Geometric accuracy of 3D coordinates of the Leksell stereotactic skull frame in 1.5 Tesla- and 3.0 Tesla-magnetic resonance imaging: a comparison of three different fixation screw materials |
title_full_unstemmed | Geometric accuracy of 3D coordinates of the Leksell stereotactic skull frame in 1.5 Tesla- and 3.0 Tesla-magnetic resonance imaging: a comparison of three different fixation screw materials |
title_short | Geometric accuracy of 3D coordinates of the Leksell stereotactic skull frame in 1.5 Tesla- and 3.0 Tesla-magnetic resonance imaging: a comparison of three different fixation screw materials |
title_sort | geometric accuracy of 3d coordinates of the leksell stereotactic skull frame in 1.5 tesla- and 3.0 tesla-magnetic resonance imaging: a comparison of three different fixation screw materials |
topic | Technology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4229929/ https://www.ncbi.nlm.nih.gov/pubmed/25034732 http://dx.doi.org/10.1093/jrr/rru064 |
work_keys_str_mv | AT nakazawahisato geometricaccuracyof3dcoordinatesoftheleksellstereotacticskullframein15teslaand30teslamagneticresonanceimagingacomparisonofthreedifferentfixationscrewmaterials AT moriyoshimasa geometricaccuracyof3dcoordinatesoftheleksellstereotacticskullframein15teslaand30teslamagneticresonanceimagingacomparisonofthreedifferentfixationscrewmaterials AT yamamuroosamu geometricaccuracyof3dcoordinatesoftheleksellstereotacticskullframein15teslaand30teslamagneticresonanceimagingacomparisonofthreedifferentfixationscrewmaterials AT komorimasataka geometricaccuracyof3dcoordinatesoftheleksellstereotacticskullframein15teslaand30teslamagneticresonanceimagingacomparisonofthreedifferentfixationscrewmaterials AT shibamotoyuta geometricaccuracyof3dcoordinatesoftheleksellstereotacticskullframein15teslaand30teslamagneticresonanceimagingacomparisonofthreedifferentfixationscrewmaterials AT uchiyamayukio geometricaccuracyof3dcoordinatesoftheleksellstereotacticskullframein15teslaand30teslamagneticresonanceimagingacomparisonofthreedifferentfixationscrewmaterials AT tsugawatakahiko geometricaccuracyof3dcoordinatesoftheleksellstereotacticskullframein15teslaand30teslamagneticresonanceimagingacomparisonofthreedifferentfixationscrewmaterials AT hagiwaramasahiro geometricaccuracyof3dcoordinatesoftheleksellstereotacticskullframein15teslaand30teslamagneticresonanceimagingacomparisonofthreedifferentfixationscrewmaterials |