Measurement precision and biological variation of cranial arteries using automated analysis of 3 T magnetic resonance angiography
BACKGROUND: Non-invasive magnetic resonance angiography (MRA) has facilitated repeated measurements of human cranial arteries in several headache and migraine studies. To ensure comparability across studies the same automated analysis software has been used, but the intra- and interobserver, day-to-...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4229959/ https://www.ncbi.nlm.nih.gov/pubmed/24886137 http://dx.doi.org/10.1186/1129-2377-15-25 |
_version_ | 1782344198692798464 |
---|---|
author | Amin, Faisal Mohammad Lundholm, Elisabet Hougaard, Anders Arngrim, Nanna Wiinberg, Linda de Koning, Patrick JH Larsson, Henrik BW Ashina, Messoud |
author_facet | Amin, Faisal Mohammad Lundholm, Elisabet Hougaard, Anders Arngrim, Nanna Wiinberg, Linda de Koning, Patrick JH Larsson, Henrik BW Ashina, Messoud |
author_sort | Amin, Faisal Mohammad |
collection | PubMed |
description | BACKGROUND: Non-invasive magnetic resonance angiography (MRA) has facilitated repeated measurements of human cranial arteries in several headache and migraine studies. To ensure comparability across studies the same automated analysis software has been used, but the intra- and interobserver, day-to-day and side-to-side variations have not yet been published. We hypothesised that the observer related, side-to-side, and day-to-day variations would be less than 10%. METHODS: Ten female participants were studied using high-resolution MRA on two study days separated by at least one week. Using the automated LKEB-MRA vessel wall analysis software arterial circumferences were measured by blinded observers. Each artery was analysed twice by each of the two different observers. The primary endpoints were to determine the intraclass correlation coefficient (ICC) and intra- an inter-observer, the day-to-day, and side-to-side variations of the circumference of the middle meningeal (MMA) and middle cerebral (MCA) arteries. RESULTS: We found an excellent intra- and interobserver agreement for the MMA (ICC: 0.909-0.987) and for the MCA (ICC: 0.876-0.949). The coefficient of variance within observers was ≤1.8% for MMA and ≤3.1% for MCA; between observers ≤3.4% (MMA) and ≤4.1% (MCA); between days ≤6.0% (MMA) and ≤8.0% (MCA); between sides ≤9.4% (MMA) and ≤6.5% (MCA). CONCLUSION: The present study demonstrates a low (<5%) inter- and intraobserver variation using the automated LKEB-MRA vessel wall analysis software. Furthermore, the study also suggests that the day-to-day and side-to-side variations of the MMA and MCA circumferences are less than 10%. |
format | Online Article Text |
id | pubmed-4229959 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | Springer |
record_format | MEDLINE/PubMed |
spelling | pubmed-42299592014-11-14 Measurement precision and biological variation of cranial arteries using automated analysis of 3 T magnetic resonance angiography Amin, Faisal Mohammad Lundholm, Elisabet Hougaard, Anders Arngrim, Nanna Wiinberg, Linda de Koning, Patrick JH Larsson, Henrik BW Ashina, Messoud J Headache Pain Research Article BACKGROUND: Non-invasive magnetic resonance angiography (MRA) has facilitated repeated measurements of human cranial arteries in several headache and migraine studies. To ensure comparability across studies the same automated analysis software has been used, but the intra- and interobserver, day-to-day and side-to-side variations have not yet been published. We hypothesised that the observer related, side-to-side, and day-to-day variations would be less than 10%. METHODS: Ten female participants were studied using high-resolution MRA on two study days separated by at least one week. Using the automated LKEB-MRA vessel wall analysis software arterial circumferences were measured by blinded observers. Each artery was analysed twice by each of the two different observers. The primary endpoints were to determine the intraclass correlation coefficient (ICC) and intra- an inter-observer, the day-to-day, and side-to-side variations of the circumference of the middle meningeal (MMA) and middle cerebral (MCA) arteries. RESULTS: We found an excellent intra- and interobserver agreement for the MMA (ICC: 0.909-0.987) and for the MCA (ICC: 0.876-0.949). The coefficient of variance within observers was ≤1.8% for MMA and ≤3.1% for MCA; between observers ≤3.4% (MMA) and ≤4.1% (MCA); between days ≤6.0% (MMA) and ≤8.0% (MCA); between sides ≤9.4% (MMA) and ≤6.5% (MCA). CONCLUSION: The present study demonstrates a low (<5%) inter- and intraobserver variation using the automated LKEB-MRA vessel wall analysis software. Furthermore, the study also suggests that the day-to-day and side-to-side variations of the MMA and MCA circumferences are less than 10%. Springer 2014 2014-05-07 /pmc/articles/PMC4229959/ /pubmed/24886137 http://dx.doi.org/10.1186/1129-2377-15-25 Text en Copyright © 2014 Amin et al.; licensee Springer. http://creativecommons.org/licenses/by/4.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License ( http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited. |
spellingShingle | Research Article Amin, Faisal Mohammad Lundholm, Elisabet Hougaard, Anders Arngrim, Nanna Wiinberg, Linda de Koning, Patrick JH Larsson, Henrik BW Ashina, Messoud Measurement precision and biological variation of cranial arteries using automated analysis of 3 T magnetic resonance angiography |
title | Measurement precision and biological variation of cranial arteries using automated analysis of 3 T magnetic resonance angiography |
title_full | Measurement precision and biological variation of cranial arteries using automated analysis of 3 T magnetic resonance angiography |
title_fullStr | Measurement precision and biological variation of cranial arteries using automated analysis of 3 T magnetic resonance angiography |
title_full_unstemmed | Measurement precision and biological variation of cranial arteries using automated analysis of 3 T magnetic resonance angiography |
title_short | Measurement precision and biological variation of cranial arteries using automated analysis of 3 T magnetic resonance angiography |
title_sort | measurement precision and biological variation of cranial arteries using automated analysis of 3 t magnetic resonance angiography |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4229959/ https://www.ncbi.nlm.nih.gov/pubmed/24886137 http://dx.doi.org/10.1186/1129-2377-15-25 |
work_keys_str_mv | AT aminfaisalmohammad measurementprecisionandbiologicalvariationofcranialarteriesusingautomatedanalysisof3tmagneticresonanceangiography AT lundholmelisabet measurementprecisionandbiologicalvariationofcranialarteriesusingautomatedanalysisof3tmagneticresonanceangiography AT hougaardanders measurementprecisionandbiologicalvariationofcranialarteriesusingautomatedanalysisof3tmagneticresonanceangiography AT arngrimnanna measurementprecisionandbiologicalvariationofcranialarteriesusingautomatedanalysisof3tmagneticresonanceangiography AT wiinberglinda measurementprecisionandbiologicalvariationofcranialarteriesusingautomatedanalysisof3tmagneticresonanceangiography AT dekoningpatrickjh measurementprecisionandbiologicalvariationofcranialarteriesusingautomatedanalysisof3tmagneticresonanceangiography AT larssonhenrikbw measurementprecisionandbiologicalvariationofcranialarteriesusingautomatedanalysisof3tmagneticresonanceangiography AT ashinamessoud measurementprecisionandbiologicalvariationofcranialarteriesusingautomatedanalysisof3tmagneticresonanceangiography |