Cargando…

All levels versus alternate levels plate fixation in expansive open door cervical laminoplasty

BACKGROUND: Expansive open door laminoplasty with the use of titanium miniplate is becoming popular. Usually, the plate is applied at each level to prevent re-closure of the opened lamina. However, it is also used at alternating levels (i.e., C3, C5 and C7) in clinical settings in order to reduce th...

Descripción completa

Detalles Bibliográficos
Autores principales: Wang, Zheng-Fei, Chen, Guang-Dong, Xue, Feng, Sheng, Xiao-Wen, Yang, Hui-Lin, Qian, Jun
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4232827/
https://www.ncbi.nlm.nih.gov/pubmed/25404770
http://dx.doi.org/10.4103/0019-5413.144225
_version_ 1782344647232716800
author Wang, Zheng-Fei
Chen, Guang-Dong
Xue, Feng
Sheng, Xiao-Wen
Yang, Hui-Lin
Qian, Jun
author_facet Wang, Zheng-Fei
Chen, Guang-Dong
Xue, Feng
Sheng, Xiao-Wen
Yang, Hui-Lin
Qian, Jun
author_sort Wang, Zheng-Fei
collection PubMed
description BACKGROUND: Expansive open door laminoplasty with the use of titanium miniplate is becoming popular. Usually, the plate is applied at each level to prevent re-closure of the opened lamina. However, it is also used at alternating levels (i.e., C3, C5 and C7) in clinical settings in order to reduce the cost. Whether they have any difference in clinical efficacy? There is a lack of comparative data between the two kinds of plate fixation in the literature. MATERIALS AND METHODS: 83 patients who underwent cervical laminoplasty with alternating levels plate fixation (51 patients in Group A) or all levels plate fixation (32 patients in Group B) between January 2008 and October 2012 were evaluated in our institute retrospectively. Clinical and radiologic outcomes were assessed. RESULTS: No statistical difference was found in the mean operation time, blood loss, incidence of significant axial symptoms and C5 palsy, preoperative anteroposterior diameter (APD) and preoperative Japanese Orthopedic Association score between the two groups. However, Group B showed a higher rate of neurologic recovery after surgery. Postoperative increased APD and open angle in Group B were significantly larger than Group A. The mean cost for Group B (12801 ± 460.6 USD) was higher than Group A (8906 ± 566.7 USD). CONCLUSIONS: Despite the higher cost of all level fixation, it is more effective in maintaining the expansion of the spinal canal and can obtain better clinical improvement compared to alternating levels fixation.
format Online
Article
Text
id pubmed-4232827
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-42328272014-11-17 All levels versus alternate levels plate fixation in expansive open door cervical laminoplasty Wang, Zheng-Fei Chen, Guang-Dong Xue, Feng Sheng, Xiao-Wen Yang, Hui-Lin Qian, Jun Indian J Orthop Original Article BACKGROUND: Expansive open door laminoplasty with the use of titanium miniplate is becoming popular. Usually, the plate is applied at each level to prevent re-closure of the opened lamina. However, it is also used at alternating levels (i.e., C3, C5 and C7) in clinical settings in order to reduce the cost. Whether they have any difference in clinical efficacy? There is a lack of comparative data between the two kinds of plate fixation in the literature. MATERIALS AND METHODS: 83 patients who underwent cervical laminoplasty with alternating levels plate fixation (51 patients in Group A) or all levels plate fixation (32 patients in Group B) between January 2008 and October 2012 were evaluated in our institute retrospectively. Clinical and radiologic outcomes were assessed. RESULTS: No statistical difference was found in the mean operation time, blood loss, incidence of significant axial symptoms and C5 palsy, preoperative anteroposterior diameter (APD) and preoperative Japanese Orthopedic Association score between the two groups. However, Group B showed a higher rate of neurologic recovery after surgery. Postoperative increased APD and open angle in Group B were significantly larger than Group A. The mean cost for Group B (12801 ± 460.6 USD) was higher than Group A (8906 ± 566.7 USD). CONCLUSIONS: Despite the higher cost of all level fixation, it is more effective in maintaining the expansion of the spinal canal and can obtain better clinical improvement compared to alternating levels fixation. Medknow Publications & Media Pvt Ltd 2014 /pmc/articles/PMC4232827/ /pubmed/25404770 http://dx.doi.org/10.4103/0019-5413.144225 Text en Copyright: © Indian Journal of Orthopaedics http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Wang, Zheng-Fei
Chen, Guang-Dong
Xue, Feng
Sheng, Xiao-Wen
Yang, Hui-Lin
Qian, Jun
All levels versus alternate levels plate fixation in expansive open door cervical laminoplasty
title All levels versus alternate levels plate fixation in expansive open door cervical laminoplasty
title_full All levels versus alternate levels plate fixation in expansive open door cervical laminoplasty
title_fullStr All levels versus alternate levels plate fixation in expansive open door cervical laminoplasty
title_full_unstemmed All levels versus alternate levels plate fixation in expansive open door cervical laminoplasty
title_short All levels versus alternate levels plate fixation in expansive open door cervical laminoplasty
title_sort all levels versus alternate levels plate fixation in expansive open door cervical laminoplasty
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4232827/
https://www.ncbi.nlm.nih.gov/pubmed/25404770
http://dx.doi.org/10.4103/0019-5413.144225
work_keys_str_mv AT wangzhengfei alllevelsversusalternatelevelsplatefixationinexpansiveopendoorcervicallaminoplasty
AT chenguangdong alllevelsversusalternatelevelsplatefixationinexpansiveopendoorcervicallaminoplasty
AT xuefeng alllevelsversusalternatelevelsplatefixationinexpansiveopendoorcervicallaminoplasty
AT shengxiaowen alllevelsversusalternatelevelsplatefixationinexpansiveopendoorcervicallaminoplasty
AT yanghuilin alllevelsversusalternatelevelsplatefixationinexpansiveopendoorcervicallaminoplasty
AT qianjun alllevelsversusalternatelevelsplatefixationinexpansiveopendoorcervicallaminoplasty