Cargando…

Marked First Degree Atrioventricular Block: an extremely prolonged PR interval associated with Atrioventricular Dissociation in a young Nigerian man with Pseudo-Pacemaker Syndrome: a case report

BACKGROUND: The diagnosis of Marked First Degree Atrioventricular Block is made with electrocardiogram when PR interval ≥0.30 s. A PR interval of up to 0.48 s had been reported in literature. Data is sparse on an extremely prolonged PR interval associated with Atrioventricular Dissociation and Pseud...

Descripción completa

Detalles Bibliográficos
Autores principales: Ogunlade, Oluwadare, Akintomide, Anthony O, Ajayi, Olufemi E, Eluwole, Omotayo A
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4233104/
https://www.ncbi.nlm.nih.gov/pubmed/25371009
http://dx.doi.org/10.1186/1756-0500-7-781
_version_ 1782344690408882176
author Ogunlade, Oluwadare
Akintomide, Anthony O
Ajayi, Olufemi E
Eluwole, Omotayo A
author_facet Ogunlade, Oluwadare
Akintomide, Anthony O
Ajayi, Olufemi E
Eluwole, Omotayo A
author_sort Ogunlade, Oluwadare
collection PubMed
description BACKGROUND: The diagnosis of Marked First Degree Atrioventricular Block is made with electrocardiogram when PR interval ≥0.30 s. A PR interval of up to 0.48 s had been reported in literature. Data is sparse on an extremely prolonged PR interval associated with Atrioventricular Dissociation and Pseudo-Pacemaker Syndrome. Electrocardiogram with this type of uncommon features poses diagnostic and management challenges in clinical practice. CASE PRESENTATION: We report a case of a 22 year old Nigerian male from Igbo ethnic group who presented himself for medical screening with a history of exercise intolerance, occasional palpitation and fainting spells. He has no history of cough, orthopnoea, paroxysmal nocturnal dyspnoea nor body swelling. A physical examination revealed that the patient has a pulse rate of 64 beats per minute, blood pressure of 110/70 mmHg and soft heart sounds. Standard 12-lead electrocardiogram showed an uncommon Marked First Degree Atrioventricular Block with an extremely prolonged PR interval of 0.56 s. Long rhythm strips of the electrocardiogram showed extremely prolonged PR interval associated with Atrioventricular Dissociation and variable degrees of Atrioventricular Block (Mobitz type I and II). CONCLUSIONS: An extremely prolonged PR interval may occur in First Degree Atrioventricular Block and it may be associated with Atrioventricular Dissociation and Pseudo-Pacemaker Syndrome which may pose diagnostic and management challenges. This suggests that not all cases of First Degree Atrioventricular Block are benign and so should be sub-classified based on degree of PR interval prolongation and associated electrical abnormalities.
format Online
Article
Text
id pubmed-4233104
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-42331042014-11-17 Marked First Degree Atrioventricular Block: an extremely prolonged PR interval associated with Atrioventricular Dissociation in a young Nigerian man with Pseudo-Pacemaker Syndrome: a case report Ogunlade, Oluwadare Akintomide, Anthony O Ajayi, Olufemi E Eluwole, Omotayo A BMC Res Notes Case Report BACKGROUND: The diagnosis of Marked First Degree Atrioventricular Block is made with electrocardiogram when PR interval ≥0.30 s. A PR interval of up to 0.48 s had been reported in literature. Data is sparse on an extremely prolonged PR interval associated with Atrioventricular Dissociation and Pseudo-Pacemaker Syndrome. Electrocardiogram with this type of uncommon features poses diagnostic and management challenges in clinical practice. CASE PRESENTATION: We report a case of a 22 year old Nigerian male from Igbo ethnic group who presented himself for medical screening with a history of exercise intolerance, occasional palpitation and fainting spells. He has no history of cough, orthopnoea, paroxysmal nocturnal dyspnoea nor body swelling. A physical examination revealed that the patient has a pulse rate of 64 beats per minute, blood pressure of 110/70 mmHg and soft heart sounds. Standard 12-lead electrocardiogram showed an uncommon Marked First Degree Atrioventricular Block with an extremely prolonged PR interval of 0.56 s. Long rhythm strips of the electrocardiogram showed extremely prolonged PR interval associated with Atrioventricular Dissociation and variable degrees of Atrioventricular Block (Mobitz type I and II). CONCLUSIONS: An extremely prolonged PR interval may occur in First Degree Atrioventricular Block and it may be associated with Atrioventricular Dissociation and Pseudo-Pacemaker Syndrome which may pose diagnostic and management challenges. This suggests that not all cases of First Degree Atrioventricular Block are benign and so should be sub-classified based on degree of PR interval prolongation and associated electrical abnormalities. BioMed Central 2014-11-04 /pmc/articles/PMC4233104/ /pubmed/25371009 http://dx.doi.org/10.1186/1756-0500-7-781 Text en © Ogunlade et al.; licensee BioMed Central Ltd. 2014 This article is published under license to BioMed Central Ltd. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Case Report
Ogunlade, Oluwadare
Akintomide, Anthony O
Ajayi, Olufemi E
Eluwole, Omotayo A
Marked First Degree Atrioventricular Block: an extremely prolonged PR interval associated with Atrioventricular Dissociation in a young Nigerian man with Pseudo-Pacemaker Syndrome: a case report
title Marked First Degree Atrioventricular Block: an extremely prolonged PR interval associated with Atrioventricular Dissociation in a young Nigerian man with Pseudo-Pacemaker Syndrome: a case report
title_full Marked First Degree Atrioventricular Block: an extremely prolonged PR interval associated with Atrioventricular Dissociation in a young Nigerian man with Pseudo-Pacemaker Syndrome: a case report
title_fullStr Marked First Degree Atrioventricular Block: an extremely prolonged PR interval associated with Atrioventricular Dissociation in a young Nigerian man with Pseudo-Pacemaker Syndrome: a case report
title_full_unstemmed Marked First Degree Atrioventricular Block: an extremely prolonged PR interval associated with Atrioventricular Dissociation in a young Nigerian man with Pseudo-Pacemaker Syndrome: a case report
title_short Marked First Degree Atrioventricular Block: an extremely prolonged PR interval associated with Atrioventricular Dissociation in a young Nigerian man with Pseudo-Pacemaker Syndrome: a case report
title_sort marked first degree atrioventricular block: an extremely prolonged pr interval associated with atrioventricular dissociation in a young nigerian man with pseudo-pacemaker syndrome: a case report
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4233104/
https://www.ncbi.nlm.nih.gov/pubmed/25371009
http://dx.doi.org/10.1186/1756-0500-7-781
work_keys_str_mv AT ogunladeoluwadare markedfirstdegreeatrioventricularblockanextremelyprolongedprintervalassociatedwithatrioventriculardissociationinayoungnigerianmanwithpseudopacemakersyndromeacasereport
AT akintomideanthonyo markedfirstdegreeatrioventricularblockanextremelyprolongedprintervalassociatedwithatrioventriculardissociationinayoungnigerianmanwithpseudopacemakersyndromeacasereport
AT ajayiolufemie markedfirstdegreeatrioventricularblockanextremelyprolongedprintervalassociatedwithatrioventriculardissociationinayoungnigerianmanwithpseudopacemakersyndromeacasereport
AT eluwoleomotayoa markedfirstdegreeatrioventricularblockanextremelyprolongedprintervalassociatedwithatrioventriculardissociationinayoungnigerianmanwithpseudopacemakersyndromeacasereport