Cargando…
Systemic review on highly qualified screening tests for swallowing disorders following stroke: Validity and reliability issues
BACKGROUND: Oropharyngeal dysphagia following stroke enhances the risk of dehydration, malnutrition, aspiration pneumonia, persistent disablement, and even death. Screening of dysphagia has been shown to positively change health outcomes. The aim of the present study was to systematically introduce...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Medknow Publications & Media Pvt Ltd
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4235100/ https://www.ncbi.nlm.nih.gov/pubmed/25422665 |
_version_ | 1782344967390232576 |
---|---|
author | Poorjavad, Marziyeh Jalaie, Shohreh |
author_facet | Poorjavad, Marziyeh Jalaie, Shohreh |
author_sort | Poorjavad, Marziyeh |
collection | PubMed |
description | BACKGROUND: Oropharyngeal dysphagia following stroke enhances the risk of dehydration, malnutrition, aspiration pneumonia, persistent disablement, and even death. Screening of dysphagia has been shown to positively change health outcomes. The aim of the present study was to systematically introduce the published swallowing screening methods in patients with stroke and their appropriateness for detecting swallowing disorders following stroke with an emphasis on the methodological quality of their research studies. MATERIALS AND METHODS: A computerized search through the Medline (PubMed), Embase, Scopus, and Google Scholar; databases from 1990 through 20 July 2013 was performed. In addition, the related citations and reference lists of the selected articles were considered. RESULTS: A total of 264 papers were retrieved and 19 articles finally met inclusion criteria. Sixty-eight percent of included papers did not have a sufficient quality and only six articles were scored as having evidence level ‘I’ and were reported descriptively. The most prevalent bias in the included studies was probably a kind of spectrum bias that could lead to select just a subgroup of admitted stroke patients. The screening tests’ sensitivities ranged from 47 to 100%, while their specificities ranged from about 63 to 100%. Strengths and limitations of each test have been discussed. CONCLUSION: We ultimately found four simple, valid, reliable, sensitive, and specific tests for screening swallowing disorders in the almost all acute alert stroke patients. Further validation and reliability assessing of screening tests need to follow a very accurate and well-established method in a large sample of the almost all acute alert stroke patients admitted to the hospitals. |
format | Online Article Text |
id | pubmed-4235100 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | Medknow Publications & Media Pvt Ltd |
record_format | MEDLINE/PubMed |
spelling | pubmed-42351002014-11-24 Systemic review on highly qualified screening tests for swallowing disorders following stroke: Validity and reliability issues Poorjavad, Marziyeh Jalaie, Shohreh J Res Med Sci Review Article BACKGROUND: Oropharyngeal dysphagia following stroke enhances the risk of dehydration, malnutrition, aspiration pneumonia, persistent disablement, and even death. Screening of dysphagia has been shown to positively change health outcomes. The aim of the present study was to systematically introduce the published swallowing screening methods in patients with stroke and their appropriateness for detecting swallowing disorders following stroke with an emphasis on the methodological quality of their research studies. MATERIALS AND METHODS: A computerized search through the Medline (PubMed), Embase, Scopus, and Google Scholar; databases from 1990 through 20 July 2013 was performed. In addition, the related citations and reference lists of the selected articles were considered. RESULTS: A total of 264 papers were retrieved and 19 articles finally met inclusion criteria. Sixty-eight percent of included papers did not have a sufficient quality and only six articles were scored as having evidence level ‘I’ and were reported descriptively. The most prevalent bias in the included studies was probably a kind of spectrum bias that could lead to select just a subgroup of admitted stroke patients. The screening tests’ sensitivities ranged from 47 to 100%, while their specificities ranged from about 63 to 100%. Strengths and limitations of each test have been discussed. CONCLUSION: We ultimately found four simple, valid, reliable, sensitive, and specific tests for screening swallowing disorders in the almost all acute alert stroke patients. Further validation and reliability assessing of screening tests need to follow a very accurate and well-established method in a large sample of the almost all acute alert stroke patients admitted to the hospitals. Medknow Publications & Media Pvt Ltd 2014-08 /pmc/articles/PMC4235100/ /pubmed/25422665 Text en Copyright: © Journal of Research in Medical Sciences http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Review Article Poorjavad, Marziyeh Jalaie, Shohreh Systemic review on highly qualified screening tests for swallowing disorders following stroke: Validity and reliability issues |
title | Systemic review on highly qualified screening tests for swallowing disorders following stroke: Validity and reliability issues |
title_full | Systemic review on highly qualified screening tests for swallowing disorders following stroke: Validity and reliability issues |
title_fullStr | Systemic review on highly qualified screening tests for swallowing disorders following stroke: Validity and reliability issues |
title_full_unstemmed | Systemic review on highly qualified screening tests for swallowing disorders following stroke: Validity and reliability issues |
title_short | Systemic review on highly qualified screening tests for swallowing disorders following stroke: Validity and reliability issues |
title_sort | systemic review on highly qualified screening tests for swallowing disorders following stroke: validity and reliability issues |
topic | Review Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4235100/ https://www.ncbi.nlm.nih.gov/pubmed/25422665 |
work_keys_str_mv | AT poorjavadmarziyeh systemicreviewonhighlyqualifiedscreeningtestsforswallowingdisordersfollowingstrokevalidityandreliabilityissues AT jalaieshohreh systemicreviewonhighlyqualifiedscreeningtestsforswallowingdisordersfollowingstrokevalidityandreliabilityissues |