Cargando…
Comparison of the air-Q intubating laryngeal airway and the cobra perilaryngeal airway as conduits for fiber optic-guided intubation in pediatric patients
BACKGROUND: One of the methods proposed in cases of difficult airway management in children is using a supraglottic airway device as a conduit for tracheal intubation. The aim of this study was to compare the efficacy of the Air-Q Intubating Laryngeal Airway (Air-Q) and the Cobra Perilaryngeal Airwa...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Medknow Publications & Media Pvt Ltd
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4236932/ https://www.ncbi.nlm.nih.gov/pubmed/25422603 http://dx.doi.org/10.4103/1658-354X.140841 |
Sumario: | BACKGROUND: One of the methods proposed in cases of difficult airway management in children is using a supraglottic airway device as a conduit for tracheal intubation. The aim of this study was to compare the efficacy of the Air-Q Intubating Laryngeal Airway (Air-Q) and the Cobra Perilaryngeal Airway (CobraPLA) to function as a conduit for fiber optic-guided tracheal intubation in pediatric patients. MATERIALS AND METHODS: A total of 60 children with ages ranging from 1 to 6 years, undergoing elective surgery, were randomized to have their airway managed with either an Air-Q or CobraPLA. Outcomes recorded were the success rate, time and number of attempts required for fiber optic-guided intubation and the time required for device removal after intubation. We also recorded airway leak pressure (ALP), fiber optic grade of glottic view and occurrence of complications. RESULTS: Both devices were successfully inserted in all patients. The intubation success rate was comparable with the Air-Q and the CobraPLA (96.7% vs. 90%), as was the first attempt success rate (90% vs. 80%). The intubation time was significantly longer with the CobraPLA (29.5 ± 10.9 s vs. 23.2 ± 9.8 s; P < 0.05), but the device removal time was comparable in the two groups. The CobraPLA showed a significantly higher ALP (20.8 ± 5.2 cmH(2)O vs. 16.3 ± 4.5 cmH(2)O; P < 0.001), but the fiber optic grade of glottic view was comparable with the two devices. The CobraPLA was associated with a significantly higher incidence of blood staining of the device on removal and post-operative sore throat. CONCLUSION: Both the Air-Q and CobraPLA can be used effectively as a conduit for fiber optic-guided tracheal intubation in children. However, the Air-Q proved to be superior due to a shorter intubation time and less airway morbidity compared with the CobraPLA. |
---|