Comparison of the air-Q intubating laryngeal airway and the cobra perilaryngeal airway as conduits for fiber optic-guided intubation in pediatric patients

BACKGROUND: One of the methods proposed in cases of difficult airway management in children is using a supraglottic airway device as a conduit for tracheal intubation. The aim of this study was to compare the efficacy of the Air-Q Intubating Laryngeal Airway (Air-Q) and the Cobra Perilaryngeal Airwa...

Descripción completa

Detalles Bibliográficos
Autores principales: Girgis, Karim K., Youssef, Maha M. I., ElZayyat, Nashwa S.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4236932/
https://www.ncbi.nlm.nih.gov/pubmed/25422603
http://dx.doi.org/10.4103/1658-354X.140841
_version_ 1782345262364098560
author Girgis, Karim K.
Youssef, Maha M. I.
ElZayyat, Nashwa S.
author_facet Girgis, Karim K.
Youssef, Maha M. I.
ElZayyat, Nashwa S.
author_sort Girgis, Karim K.
collection PubMed
description BACKGROUND: One of the methods proposed in cases of difficult airway management in children is using a supraglottic airway device as a conduit for tracheal intubation. The aim of this study was to compare the efficacy of the Air-Q Intubating Laryngeal Airway (Air-Q) and the Cobra Perilaryngeal Airway (CobraPLA) to function as a conduit for fiber optic-guided tracheal intubation in pediatric patients. MATERIALS AND METHODS: A total of 60 children with ages ranging from 1 to 6 years, undergoing elective surgery, were randomized to have their airway managed with either an Air-Q or CobraPLA. Outcomes recorded were the success rate, time and number of attempts required for fiber optic-guided intubation and the time required for device removal after intubation. We also recorded airway leak pressure (ALP), fiber optic grade of glottic view and occurrence of complications. RESULTS: Both devices were successfully inserted in all patients. The intubation success rate was comparable with the Air-Q and the CobraPLA (96.7% vs. 90%), as was the first attempt success rate (90% vs. 80%). The intubation time was significantly longer with the CobraPLA (29.5 ± 10.9 s vs. 23.2 ± 9.8 s; P < 0.05), but the device removal time was comparable in the two groups. The CobraPLA showed a significantly higher ALP (20.8 ± 5.2 cmH(2)O vs. 16.3 ± 4.5 cmH(2)O; P < 0.001), but the fiber optic grade of glottic view was comparable with the two devices. The CobraPLA was associated with a significantly higher incidence of blood staining of the device on removal and post-operative sore throat. CONCLUSION: Both the Air-Q and CobraPLA can be used effectively as a conduit for fiber optic-guided tracheal intubation in children. However, the Air-Q proved to be superior due to a shorter intubation time and less airway morbidity compared with the CobraPLA.
format Online
Article
Text
id pubmed-4236932
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-42369322014-11-24 Comparison of the air-Q intubating laryngeal airway and the cobra perilaryngeal airway as conduits for fiber optic-guided intubation in pediatric patients Girgis, Karim K. Youssef, Maha M. I. ElZayyat, Nashwa S. Saudi J Anaesth Original Article BACKGROUND: One of the methods proposed in cases of difficult airway management in children is using a supraglottic airway device as a conduit for tracheal intubation. The aim of this study was to compare the efficacy of the Air-Q Intubating Laryngeal Airway (Air-Q) and the Cobra Perilaryngeal Airway (CobraPLA) to function as a conduit for fiber optic-guided tracheal intubation in pediatric patients. MATERIALS AND METHODS: A total of 60 children with ages ranging from 1 to 6 years, undergoing elective surgery, were randomized to have their airway managed with either an Air-Q or CobraPLA. Outcomes recorded were the success rate, time and number of attempts required for fiber optic-guided intubation and the time required for device removal after intubation. We also recorded airway leak pressure (ALP), fiber optic grade of glottic view and occurrence of complications. RESULTS: Both devices were successfully inserted in all patients. The intubation success rate was comparable with the Air-Q and the CobraPLA (96.7% vs. 90%), as was the first attempt success rate (90% vs. 80%). The intubation time was significantly longer with the CobraPLA (29.5 ± 10.9 s vs. 23.2 ± 9.8 s; P < 0.05), but the device removal time was comparable in the two groups. The CobraPLA showed a significantly higher ALP (20.8 ± 5.2 cmH(2)O vs. 16.3 ± 4.5 cmH(2)O; P < 0.001), but the fiber optic grade of glottic view was comparable with the two devices. The CobraPLA was associated with a significantly higher incidence of blood staining of the device on removal and post-operative sore throat. CONCLUSION: Both the Air-Q and CobraPLA can be used effectively as a conduit for fiber optic-guided tracheal intubation in children. However, the Air-Q proved to be superior due to a shorter intubation time and less airway morbidity compared with the CobraPLA. Medknow Publications & Media Pvt Ltd 2014 /pmc/articles/PMC4236932/ /pubmed/25422603 http://dx.doi.org/10.4103/1658-354X.140841 Text en Copyright: © Saudi Journal of Anaesthesia http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Girgis, Karim K.
Youssef, Maha M. I.
ElZayyat, Nashwa S.
Comparison of the air-Q intubating laryngeal airway and the cobra perilaryngeal airway as conduits for fiber optic-guided intubation in pediatric patients
title Comparison of the air-Q intubating laryngeal airway and the cobra perilaryngeal airway as conduits for fiber optic-guided intubation in pediatric patients
title_full Comparison of the air-Q intubating laryngeal airway and the cobra perilaryngeal airway as conduits for fiber optic-guided intubation in pediatric patients
title_fullStr Comparison of the air-Q intubating laryngeal airway and the cobra perilaryngeal airway as conduits for fiber optic-guided intubation in pediatric patients
title_full_unstemmed Comparison of the air-Q intubating laryngeal airway and the cobra perilaryngeal airway as conduits for fiber optic-guided intubation in pediatric patients
title_short Comparison of the air-Q intubating laryngeal airway and the cobra perilaryngeal airway as conduits for fiber optic-guided intubation in pediatric patients
title_sort comparison of the air-q intubating laryngeal airway and the cobra perilaryngeal airway as conduits for fiber optic-guided intubation in pediatric patients
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4236932/
https://www.ncbi.nlm.nih.gov/pubmed/25422603
http://dx.doi.org/10.4103/1658-354X.140841
work_keys_str_mv AT girgiskarimk comparisonoftheairqintubatinglaryngealairwayandthecobraperilaryngealairwayasconduitsforfiberopticguidedintubationinpediatricpatients
AT youssefmahami comparisonoftheairqintubatinglaryngealairwayandthecobraperilaryngealairwayasconduitsforfiberopticguidedintubationinpediatricpatients
AT elzayyatnashwas comparisonoftheairqintubatinglaryngealairwayandthecobraperilaryngealairwayasconduitsforfiberopticguidedintubationinpediatricpatients