Reliability Analysis of the Electrical Control System of Subsea Blowout Preventers Using Markov Models

Reliability analysis of the electrical control system of a subsea blowout preventer (BOP) stack is carried out based on Markov method. For the subsea BOP electrical control system used in the current work, the 3-2-1-0 and 3-2-0 input voting schemes are available. The effects of the voting schemes on...

Descripción completa

Detalles Bibliográficos
Autores principales: Liu, Zengkai, Liu, Yonghong, Cai, Baoping
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4237418/
https://www.ncbi.nlm.nih.gov/pubmed/25409010
http://dx.doi.org/10.1371/journal.pone.0113525
Descripción
Sumario:Reliability analysis of the electrical control system of a subsea blowout preventer (BOP) stack is carried out based on Markov method. For the subsea BOP electrical control system used in the current work, the 3-2-1-0 and 3-2-0 input voting schemes are available. The effects of the voting schemes on system performance are evaluated based on Markov models. In addition, the effects of failure rates of the modules and repair time on system reliability indices are also investigated.