Cargando…

Reliability Analysis of the Electrical Control System of Subsea Blowout Preventers Using Markov Models

Reliability analysis of the electrical control system of a subsea blowout preventer (BOP) stack is carried out based on Markov method. For the subsea BOP electrical control system used in the current work, the 3-2-1-0 and 3-2-0 input voting schemes are available. The effects of the voting schemes on...

Descripción completa

Detalles Bibliográficos
Autores principales: Liu, Zengkai, Liu, Yonghong, Cai, Baoping
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4237418/
https://www.ncbi.nlm.nih.gov/pubmed/25409010
http://dx.doi.org/10.1371/journal.pone.0113525