Cargando…

Lixisenatide resensitizes the insulin-secretory response to intravenous glucose challenge in people with type 2 diabetes – a study in both people with type 2 diabetes and healthy subjects

AIMS: Glucagon-like peptide-1 (GLP-1) receptor agonists improve blood glucose control by enhancing glucose-sensitive insulin release, delaying gastric emptying and reducing postprandial glucagon secretion. The studies reported here investigated the insulin response to an intravenous (iv) glucose cha...

Descripción completa

Detalles Bibliográficos
Autores principales: Becker, R H A, Stechl, J, Msihid, J, Kapitza, C
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Blackwell Publishing Ltd 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4237545/
https://www.ncbi.nlm.nih.gov/pubmed/24521245
http://dx.doi.org/10.1111/dom.12278
_version_ 1782345367999741952
author Becker, R H A
Stechl, J
Msihid, J
Kapitza, C
author_facet Becker, R H A
Stechl, J
Msihid, J
Kapitza, C
author_sort Becker, R H A
collection PubMed
description AIMS: Glucagon-like peptide-1 (GLP-1) receptor agonists improve blood glucose control by enhancing glucose-sensitive insulin release, delaying gastric emptying and reducing postprandial glucagon secretion. The studies reported here investigated the insulin response to an intravenous (iv) glucose challenge after injection of lixisenatide (LIXI) 20 µg or placebo. METHODS: Two single-centre, double-blind, randomized, placebo-controlled, single-dose, crossover studies were performed in healthy subjects (HS) and people with type 2 diabetes mellitus (T2DM). Participants received subcutaneous LIXI or placebo 2 h before an iv glucose challenge. Study endpoints included first- and second-phase insulin response, insulin concentration (INS), glucagon response and glucose disposal rate (K(glucose)). LIXI exposure was measured over 12 h. RESULTS: LIXI 20 µg reached maximum concentration after 2 h and resensitized first-phase insulin secretion by 2.8-fold in T2DM to rates comparable with those in HS on placebo, and raised second-phase insulin secretion by 1.6-fold in T2DM. INS rose correspondingly and glucose disposal was accelerated by 1.8-fold in T2DM. First-phase insulin secretion and glucose disposal were also augmented by LIXI in HS, whereas second-phase insulin secretion reduced blood glucose concentrations to below fasting levels and then ceased, accompanied by a rapid, short-lasting rise in glucagon. Otherwise, suppression of glucagon release subsequent to augmentation of insulin release was unaffected in T2DM and in HS. CONCLUSIONS: LIXI resensitized the insulin response to an iv glucose challenge in people with T2DM, thereby accelerating glucose disposal to nearly physiological intensity, and did not impair counter-regulation to low glucose levels by glucagon.
format Online
Article
Text
id pubmed-4237545
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Blackwell Publishing Ltd
record_format MEDLINE/PubMed
spelling pubmed-42375452014-12-15 Lixisenatide resensitizes the insulin-secretory response to intravenous glucose challenge in people with type 2 diabetes – a study in both people with type 2 diabetes and healthy subjects Becker, R H A Stechl, J Msihid, J Kapitza, C Diabetes Obes Metab Original Articles AIMS: Glucagon-like peptide-1 (GLP-1) receptor agonists improve blood glucose control by enhancing glucose-sensitive insulin release, delaying gastric emptying and reducing postprandial glucagon secretion. The studies reported here investigated the insulin response to an intravenous (iv) glucose challenge after injection of lixisenatide (LIXI) 20 µg or placebo. METHODS: Two single-centre, double-blind, randomized, placebo-controlled, single-dose, crossover studies were performed in healthy subjects (HS) and people with type 2 diabetes mellitus (T2DM). Participants received subcutaneous LIXI or placebo 2 h before an iv glucose challenge. Study endpoints included first- and second-phase insulin response, insulin concentration (INS), glucagon response and glucose disposal rate (K(glucose)). LIXI exposure was measured over 12 h. RESULTS: LIXI 20 µg reached maximum concentration after 2 h and resensitized first-phase insulin secretion by 2.8-fold in T2DM to rates comparable with those in HS on placebo, and raised second-phase insulin secretion by 1.6-fold in T2DM. INS rose correspondingly and glucose disposal was accelerated by 1.8-fold in T2DM. First-phase insulin secretion and glucose disposal were also augmented by LIXI in HS, whereas second-phase insulin secretion reduced blood glucose concentrations to below fasting levels and then ceased, accompanied by a rapid, short-lasting rise in glucagon. Otherwise, suppression of glucagon release subsequent to augmentation of insulin release was unaffected in T2DM and in HS. CONCLUSIONS: LIXI resensitized the insulin response to an iv glucose challenge in people with T2DM, thereby accelerating glucose disposal to nearly physiological intensity, and did not impair counter-regulation to low glucose levels by glucagon. Blackwell Publishing Ltd 2014-09 2014-03-25 /pmc/articles/PMC4237545/ /pubmed/24521245 http://dx.doi.org/10.1111/dom.12278 Text en © 2014 The Authors. Diabetes, Obesity and Metabolism published by John Wiley & Sons Ltd http://creativecommons.org/licenses/by-nc/3.0/ This is an open access article under the terms of the Creative Commons Attribution-NonCommercial License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited and is not used for commercial purposes.
spellingShingle Original Articles
Becker, R H A
Stechl, J
Msihid, J
Kapitza, C
Lixisenatide resensitizes the insulin-secretory response to intravenous glucose challenge in people with type 2 diabetes – a study in both people with type 2 diabetes and healthy subjects
title Lixisenatide resensitizes the insulin-secretory response to intravenous glucose challenge in people with type 2 diabetes – a study in both people with type 2 diabetes and healthy subjects
title_full Lixisenatide resensitizes the insulin-secretory response to intravenous glucose challenge in people with type 2 diabetes – a study in both people with type 2 diabetes and healthy subjects
title_fullStr Lixisenatide resensitizes the insulin-secretory response to intravenous glucose challenge in people with type 2 diabetes – a study in both people with type 2 diabetes and healthy subjects
title_full_unstemmed Lixisenatide resensitizes the insulin-secretory response to intravenous glucose challenge in people with type 2 diabetes – a study in both people with type 2 diabetes and healthy subjects
title_short Lixisenatide resensitizes the insulin-secretory response to intravenous glucose challenge in people with type 2 diabetes – a study in both people with type 2 diabetes and healthy subjects
title_sort lixisenatide resensitizes the insulin-secretory response to intravenous glucose challenge in people with type 2 diabetes – a study in both people with type 2 diabetes and healthy subjects
topic Original Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4237545/
https://www.ncbi.nlm.nih.gov/pubmed/24521245
http://dx.doi.org/10.1111/dom.12278
work_keys_str_mv AT beckerrha lixisenatideresensitizestheinsulinsecretoryresponsetointravenousglucosechallengeinpeoplewithtype2diabetesastudyinbothpeoplewithtype2diabetesandhealthysubjects
AT stechlj lixisenatideresensitizestheinsulinsecretoryresponsetointravenousglucosechallengeinpeoplewithtype2diabetesastudyinbothpeoplewithtype2diabetesandhealthysubjects
AT msihidj lixisenatideresensitizestheinsulinsecretoryresponsetointravenousglucosechallengeinpeoplewithtype2diabetesastudyinbothpeoplewithtype2diabetesandhealthysubjects
AT kapitzac lixisenatideresensitizestheinsulinsecretoryresponsetointravenousglucosechallengeinpeoplewithtype2diabetesastudyinbothpeoplewithtype2diabetesandhealthysubjects