Suture material for flexor tendon repair: 3–0 V-Loc versus 3–0 Stratafix in a biomechanical comparison ex vivo
BACKGROUND: Barbed suture material offers the possibility of knotless flexor tendon repair, as suggested in an increasing number of biomechanical studies. There are currently two different absorbable barbed suture products available, V-Loc™ and Stratafix™, and both have not been compared to each oth...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4237859/ https://www.ncbi.nlm.nih.gov/pubmed/25205062 http://dx.doi.org/10.1186/s13018-014-0072-9 |
_version_ | 1782345412157374464 |
---|---|
author | Jordan, Martin C Hölscher-Doht, Stefanie Jakubietz, Michael G Jakubietz, Rafael G Meffert, Rainer H Schmidt, Karsten |
author_facet | Jordan, Martin C Hölscher-Doht, Stefanie Jakubietz, Michael G Jakubietz, Rafael G Meffert, Rainer H Schmidt, Karsten |
author_sort | Jordan, Martin C |
collection | PubMed |
description | BACKGROUND: Barbed suture material offers the possibility of knotless flexor tendon repair, as suggested in an increasing number of biomechanical studies. There are currently two different absorbable barbed suture products available, V-Loc™ and Stratafix™, and both have not been compared to each other with regard to flexor tendon repair. The purpose of this study was to evaluate both suture materials for primary stability under static and cyclic loading in a biomechanical ex vivo model. METHODS: Forty fresh porcine flexor digitorum profundus tendons were randomized in two groups. A four-strand modified Kessler suture technique was used to repair the tendon either with a 3–0 V-Loc™ or 3–0 Stratafix™ without a knot. Parameters of interest were mode of failure, 2-mm gap formation force, displacement, stiffness and maximum load under static and cyclic testing. RESULTS: The maximum load was 42.3 ± 7.2 for the Stratafix™ group and 50.7 ± 8.8 N for the V-Loc™ group. Thus, the ultimate tensile strength was significantly higher for V-Loc™ (p < 0.05). The 2-mm gap occurred at 24.8 ± 2.04 N in the Stratafix™ group in comparison to 26.5 ± 2.12 N in the V-Loc™ group (n.s.). Displacement was 2.65 ± 0.56 mm in the V-Loc™ group and 2.71 ± 0.59 mm in the Stratafix™ group (n.s.). Stiffness was 4.24 ± 0.68 (N/mm) in the V-Loc™ group and 3.85 ± 0.55 (N/mm) the Stratafix™ group (n.s.). Those measured differences were not significant. CONCLUSION: V-Loc™ demonstrates a higher maximum load in tendon reconstruction. The differences in 2-mm gap formation force, displacement and stiffness were not significant. Hereby, the V-Loc™ has an advantage when used as unidirectional barbed suture for knotless flexor tendon repair. |
format | Online Article Text |
id | pubmed-4237859 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-42378592014-11-21 Suture material for flexor tendon repair: 3–0 V-Loc versus 3–0 Stratafix in a biomechanical comparison ex vivo Jordan, Martin C Hölscher-Doht, Stefanie Jakubietz, Michael G Jakubietz, Rafael G Meffert, Rainer H Schmidt, Karsten J Orthop Surg Res Research Article BACKGROUND: Barbed suture material offers the possibility of knotless flexor tendon repair, as suggested in an increasing number of biomechanical studies. There are currently two different absorbable barbed suture products available, V-Loc™ and Stratafix™, and both have not been compared to each other with regard to flexor tendon repair. The purpose of this study was to evaluate both suture materials for primary stability under static and cyclic loading in a biomechanical ex vivo model. METHODS: Forty fresh porcine flexor digitorum profundus tendons were randomized in two groups. A four-strand modified Kessler suture technique was used to repair the tendon either with a 3–0 V-Loc™ or 3–0 Stratafix™ without a knot. Parameters of interest were mode of failure, 2-mm gap formation force, displacement, stiffness and maximum load under static and cyclic testing. RESULTS: The maximum load was 42.3 ± 7.2 for the Stratafix™ group and 50.7 ± 8.8 N for the V-Loc™ group. Thus, the ultimate tensile strength was significantly higher for V-Loc™ (p < 0.05). The 2-mm gap occurred at 24.8 ± 2.04 N in the Stratafix™ group in comparison to 26.5 ± 2.12 N in the V-Loc™ group (n.s.). Displacement was 2.65 ± 0.56 mm in the V-Loc™ group and 2.71 ± 0.59 mm in the Stratafix™ group (n.s.). Stiffness was 4.24 ± 0.68 (N/mm) in the V-Loc™ group and 3.85 ± 0.55 (N/mm) the Stratafix™ group (n.s.). Those measured differences were not significant. CONCLUSION: V-Loc™ demonstrates a higher maximum load in tendon reconstruction. The differences in 2-mm gap formation force, displacement and stiffness were not significant. Hereby, the V-Loc™ has an advantage when used as unidirectional barbed suture for knotless flexor tendon repair. BioMed Central 2014-08-21 /pmc/articles/PMC4237859/ /pubmed/25205062 http://dx.doi.org/10.1186/s13018-014-0072-9 Text en Copyright © 2014 Jordan et al.; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Research Article Jordan, Martin C Hölscher-Doht, Stefanie Jakubietz, Michael G Jakubietz, Rafael G Meffert, Rainer H Schmidt, Karsten Suture material for flexor tendon repair: 3–0 V-Loc versus 3–0 Stratafix in a biomechanical comparison ex vivo |
title | Suture material for flexor tendon repair: 3–0 V-Loc versus 3–0 Stratafix in a biomechanical comparison ex vivo |
title_full | Suture material for flexor tendon repair: 3–0 V-Loc versus 3–0 Stratafix in a biomechanical comparison ex vivo |
title_fullStr | Suture material for flexor tendon repair: 3–0 V-Loc versus 3–0 Stratafix in a biomechanical comparison ex vivo |
title_full_unstemmed | Suture material for flexor tendon repair: 3–0 V-Loc versus 3–0 Stratafix in a biomechanical comparison ex vivo |
title_short | Suture material for flexor tendon repair: 3–0 V-Loc versus 3–0 Stratafix in a biomechanical comparison ex vivo |
title_sort | suture material for flexor tendon repair: 3–0 v-loc versus 3–0 stratafix in a biomechanical comparison ex vivo |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4237859/ https://www.ncbi.nlm.nih.gov/pubmed/25205062 http://dx.doi.org/10.1186/s13018-014-0072-9 |
work_keys_str_mv | AT jordanmartinc suturematerialforflexortendonrepair30vlocversus30stratafixinabiomechanicalcomparisonexvivo AT holscherdohtstefanie suturematerialforflexortendonrepair30vlocversus30stratafixinabiomechanicalcomparisonexvivo AT jakubietzmichaelg suturematerialforflexortendonrepair30vlocversus30stratafixinabiomechanicalcomparisonexvivo AT jakubietzrafaelg suturematerialforflexortendonrepair30vlocversus30stratafixinabiomechanicalcomparisonexvivo AT meffertrainerh suturematerialforflexortendonrepair30vlocversus30stratafixinabiomechanicalcomparisonexvivo AT schmidtkarsten suturematerialforflexortendonrepair30vlocversus30stratafixinabiomechanicalcomparisonexvivo |