Cargando…
Suture anchor fixation strength with or without augmentation in osteopenic and severely osteoporotic bones in rotator cuff repair: a biomechanical study on polyurethane foam model
BACKGROUND: The purpose of the present study was to compare the results of various types of anchor applications with or without augmentation in both osteopenic and severely osteoporotic bone models. METHODS: Two different types of suture anchors were tested in severely osteoporotic (SOP) and osteope...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4237878/ https://www.ncbi.nlm.nih.gov/pubmed/25148925 http://dx.doi.org/10.1186/1749-799X-9-48 |
_version_ | 1782345416527839232 |
---|---|
author | Er, Mehmet Serhan Altinel, Levent Eroglu, Mehmet Verim, Ozgur Demir, Teyfik Atmaca, Halil |
author_facet | Er, Mehmet Serhan Altinel, Levent Eroglu, Mehmet Verim, Ozgur Demir, Teyfik Atmaca, Halil |
author_sort | Er, Mehmet Serhan |
collection | PubMed |
description | BACKGROUND: The purpose of the present study was to compare the results of various types of anchor applications with or without augmentation in both osteopenic and severely osteoporotic bone models. METHODS: Two different types of suture anchors were tested in severely osteoporotic (SOP) and osteopenic polyurethane (PU) foam blocks using an established protocol. An Instron machine applied static loading parallel to the axis of insertion until failure, and the mean anchor failure strengths were calculated. The mode of failure (anchor pullout, suture tear) was recorded. The anchors tested included the Corkscrew® (CS) (Arthrex Inc., Naples, FL, USA) (without augmentation, polymethylmethacrylate (PMMA)-augmented, and bioabsorbable tricalcium phosphate (TCP) cement-augmented) and Corkscrew® FT II (CS FT II) 5.5 mm (without augmentation as used routinely). RESULTS: The mean failure loads for both SOP and osteopenic PU foam blocks, respectively, were as follows: CS, 16.2 and 212.4 N; CS with TCP, 75.2 and 396 N; CS with PMMA, 101.2 and 528.8 N; CS FT II, 13.8 and 339.8 N. CONCLUSIONS: Augmentation of CS with TCP or PMMA would be essential to SOP bones. In the osteopenic bone model, although anchor fixation augmented with PMMA is the best fixation method, CS augmented with TCP cement or CS FT II without any need for augmentation may also be used as an alternative. |
format | Online Article Text |
id | pubmed-4237878 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-42378782014-11-21 Suture anchor fixation strength with or without augmentation in osteopenic and severely osteoporotic bones in rotator cuff repair: a biomechanical study on polyurethane foam model Er, Mehmet Serhan Altinel, Levent Eroglu, Mehmet Verim, Ozgur Demir, Teyfik Atmaca, Halil J Orthop Surg Res Research Article BACKGROUND: The purpose of the present study was to compare the results of various types of anchor applications with or without augmentation in both osteopenic and severely osteoporotic bone models. METHODS: Two different types of suture anchors were tested in severely osteoporotic (SOP) and osteopenic polyurethane (PU) foam blocks using an established protocol. An Instron machine applied static loading parallel to the axis of insertion until failure, and the mean anchor failure strengths were calculated. The mode of failure (anchor pullout, suture tear) was recorded. The anchors tested included the Corkscrew® (CS) (Arthrex Inc., Naples, FL, USA) (without augmentation, polymethylmethacrylate (PMMA)-augmented, and bioabsorbable tricalcium phosphate (TCP) cement-augmented) and Corkscrew® FT II (CS FT II) 5.5 mm (without augmentation as used routinely). RESULTS: The mean failure loads for both SOP and osteopenic PU foam blocks, respectively, were as follows: CS, 16.2 and 212.4 N; CS with TCP, 75.2 and 396 N; CS with PMMA, 101.2 and 528.8 N; CS FT II, 13.8 and 339.8 N. CONCLUSIONS: Augmentation of CS with TCP or PMMA would be essential to SOP bones. In the osteopenic bone model, although anchor fixation augmented with PMMA is the best fixation method, CS augmented with TCP cement or CS FT II without any need for augmentation may also be used as an alternative. BioMed Central 2014-08-22 /pmc/articles/PMC4237878/ /pubmed/25148925 http://dx.doi.org/10.1186/1749-799X-9-48 Text en Copyright © 2014 Er et al.; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Research Article Er, Mehmet Serhan Altinel, Levent Eroglu, Mehmet Verim, Ozgur Demir, Teyfik Atmaca, Halil Suture anchor fixation strength with or without augmentation in osteopenic and severely osteoporotic bones in rotator cuff repair: a biomechanical study on polyurethane foam model |
title | Suture anchor fixation strength with or without augmentation in osteopenic and severely osteoporotic bones in rotator cuff repair: a biomechanical study on polyurethane foam model |
title_full | Suture anchor fixation strength with or without augmentation in osteopenic and severely osteoporotic bones in rotator cuff repair: a biomechanical study on polyurethane foam model |
title_fullStr | Suture anchor fixation strength with or without augmentation in osteopenic and severely osteoporotic bones in rotator cuff repair: a biomechanical study on polyurethane foam model |
title_full_unstemmed | Suture anchor fixation strength with or without augmentation in osteopenic and severely osteoporotic bones in rotator cuff repair: a biomechanical study on polyurethane foam model |
title_short | Suture anchor fixation strength with or without augmentation in osteopenic and severely osteoporotic bones in rotator cuff repair: a biomechanical study on polyurethane foam model |
title_sort | suture anchor fixation strength with or without augmentation in osteopenic and severely osteoporotic bones in rotator cuff repair: a biomechanical study on polyurethane foam model |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4237878/ https://www.ncbi.nlm.nih.gov/pubmed/25148925 http://dx.doi.org/10.1186/1749-799X-9-48 |
work_keys_str_mv | AT ermehmetserhan sutureanchorfixationstrengthwithorwithoutaugmentationinosteopenicandseverelyosteoporoticbonesinrotatorcuffrepairabiomechanicalstudyonpolyurethanefoammodel AT altinellevent sutureanchorfixationstrengthwithorwithoutaugmentationinosteopenicandseverelyosteoporoticbonesinrotatorcuffrepairabiomechanicalstudyonpolyurethanefoammodel AT eroglumehmet sutureanchorfixationstrengthwithorwithoutaugmentationinosteopenicandseverelyosteoporoticbonesinrotatorcuffrepairabiomechanicalstudyonpolyurethanefoammodel AT verimozgur sutureanchorfixationstrengthwithorwithoutaugmentationinosteopenicandseverelyosteoporoticbonesinrotatorcuffrepairabiomechanicalstudyonpolyurethanefoammodel AT demirteyfik sutureanchorfixationstrengthwithorwithoutaugmentationinosteopenicandseverelyosteoporoticbonesinrotatorcuffrepairabiomechanicalstudyonpolyurethanefoammodel AT atmacahalil sutureanchorfixationstrengthwithorwithoutaugmentationinosteopenicandseverelyosteoporoticbonesinrotatorcuffrepairabiomechanicalstudyonpolyurethanefoammodel |