Cargando…

Optic nerve sheath diameter as a marker for evaluation and prognostication of intracranial pressure in Indian patients: An observational study

BACKGROUND AND AIMS: The aim was to evaluate efficacy of optic nerve sheath diameter (ONSD) by ultrasound as a noninvasive method for detecting raised intracranial pressure (ICP) in intensive care unit, to compare with computed tomography/magnetic resonance imaging (MRI) findings of raised ICP and t...

Descripción completa

Detalles Bibliográficos
Autores principales: Shirodkar, Chetan G., Rao, S. Manimala, Mutkule, Dnyaneshwar P., Harde, Yogesh R., Venkategowda, Pradeep M., Mahesh, M. Uma
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4238090/
https://www.ncbi.nlm.nih.gov/pubmed/25425840
http://dx.doi.org/10.4103/0972-5229.144015
_version_ 1782345459915816960
author Shirodkar, Chetan G.
Rao, S. Manimala
Mutkule, Dnyaneshwar P.
Harde, Yogesh R.
Venkategowda, Pradeep M.
Mahesh, M. Uma
author_facet Shirodkar, Chetan G.
Rao, S. Manimala
Mutkule, Dnyaneshwar P.
Harde, Yogesh R.
Venkategowda, Pradeep M.
Mahesh, M. Uma
author_sort Shirodkar, Chetan G.
collection PubMed
description BACKGROUND AND AIMS: The aim was to evaluate efficacy of optic nerve sheath diameter (ONSD) by ultrasound as a noninvasive method for detecting raised intracranial pressure (ICP) in intensive care unit, to compare with computed tomography/magnetic resonance imaging (MRI) findings of raised ICP and to prognosticate ONSD value with treatment. MATERIALS AND METHODS: We conducted a prospective, observational study on 101 adults by including 41 healthy individuals in group A as control and 60 patients in group B admitted with fever, headache, vomiting, and altered sensorium. We examined them in supine position using 10 MHz linear array probe on closed eyelid. ONSD was measured 3 mm behind the globe in each eye. A mean binocular ONSD > 4.6 mm in female and 4.8 mm in male was considered abnormal. Midline shift, edema, effacement or ONSD > 5.0 mm on T2 MRI suggestive of elevated ICP was used to evaluate ONSD accuracy. RESULTS: Group A mean ONSD was 4.6 mm in females and 4.8 mm in males. Group B mean ONSD for 17 females was 5.103 ± 0.6221 mm (P = 0.002) and for 43 males 5.081 ± 0.5799 mm (P = 0.032). Radiological sign of raised ICP was confirmed in 35 patients (females = 11 and males = 24) with high ONSD value. Sensitivity of detecting raised ICP by ONSD was 84.6% in females and 75% in males while specificity was 100% in both genders. Out of 25 patients without radiological signs of raised ICP 10 patients showed high ONSD (females = 4.735 mm and males = 4.907 mm). ONSD was well prognosticated with treatment modalities. CONCLUSION: Bedside ocular ultrasonography for measuring ONSD can be used an early test for diagnosing raised ICP as it is a noninvasive, cost effective bedside test, which can be repeated for re-evaluation.
format Online
Article
Text
id pubmed-4238090
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-42380902014-11-25 Optic nerve sheath diameter as a marker for evaluation and prognostication of intracranial pressure in Indian patients: An observational study Shirodkar, Chetan G. Rao, S. Manimala Mutkule, Dnyaneshwar P. Harde, Yogesh R. Venkategowda, Pradeep M. Mahesh, M. Uma Indian J Crit Care Med Research Article BACKGROUND AND AIMS: The aim was to evaluate efficacy of optic nerve sheath diameter (ONSD) by ultrasound as a noninvasive method for detecting raised intracranial pressure (ICP) in intensive care unit, to compare with computed tomography/magnetic resonance imaging (MRI) findings of raised ICP and to prognosticate ONSD value with treatment. MATERIALS AND METHODS: We conducted a prospective, observational study on 101 adults by including 41 healthy individuals in group A as control and 60 patients in group B admitted with fever, headache, vomiting, and altered sensorium. We examined them in supine position using 10 MHz linear array probe on closed eyelid. ONSD was measured 3 mm behind the globe in each eye. A mean binocular ONSD > 4.6 mm in female and 4.8 mm in male was considered abnormal. Midline shift, edema, effacement or ONSD > 5.0 mm on T2 MRI suggestive of elevated ICP was used to evaluate ONSD accuracy. RESULTS: Group A mean ONSD was 4.6 mm in females and 4.8 mm in males. Group B mean ONSD for 17 females was 5.103 ± 0.6221 mm (P = 0.002) and for 43 males 5.081 ± 0.5799 mm (P = 0.032). Radiological sign of raised ICP was confirmed in 35 patients (females = 11 and males = 24) with high ONSD value. Sensitivity of detecting raised ICP by ONSD was 84.6% in females and 75% in males while specificity was 100% in both genders. Out of 25 patients without radiological signs of raised ICP 10 patients showed high ONSD (females = 4.735 mm and males = 4.907 mm). ONSD was well prognosticated with treatment modalities. CONCLUSION: Bedside ocular ultrasonography for measuring ONSD can be used an early test for diagnosing raised ICP as it is a noninvasive, cost effective bedside test, which can be repeated for re-evaluation. Medknow Publications & Media Pvt Ltd 2014-11 /pmc/articles/PMC4238090/ /pubmed/25425840 http://dx.doi.org/10.4103/0972-5229.144015 Text en Copyright: © Indian Journal of Critical Care Medicine http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Shirodkar, Chetan G.
Rao, S. Manimala
Mutkule, Dnyaneshwar P.
Harde, Yogesh R.
Venkategowda, Pradeep M.
Mahesh, M. Uma
Optic nerve sheath diameter as a marker for evaluation and prognostication of intracranial pressure in Indian patients: An observational study
title Optic nerve sheath diameter as a marker for evaluation and prognostication of intracranial pressure in Indian patients: An observational study
title_full Optic nerve sheath diameter as a marker for evaluation and prognostication of intracranial pressure in Indian patients: An observational study
title_fullStr Optic nerve sheath diameter as a marker for evaluation and prognostication of intracranial pressure in Indian patients: An observational study
title_full_unstemmed Optic nerve sheath diameter as a marker for evaluation and prognostication of intracranial pressure in Indian patients: An observational study
title_short Optic nerve sheath diameter as a marker for evaluation and prognostication of intracranial pressure in Indian patients: An observational study
title_sort optic nerve sheath diameter as a marker for evaluation and prognostication of intracranial pressure in indian patients: an observational study
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4238090/
https://www.ncbi.nlm.nih.gov/pubmed/25425840
http://dx.doi.org/10.4103/0972-5229.144015
work_keys_str_mv AT shirodkarchetang opticnervesheathdiameterasamarkerforevaluationandprognosticationofintracranialpressureinindianpatientsanobservationalstudy
AT raosmanimala opticnervesheathdiameterasamarkerforevaluationandprognosticationofintracranialpressureinindianpatientsanobservationalstudy
AT mutkulednyaneshwarp opticnervesheathdiameterasamarkerforevaluationandprognosticationofintracranialpressureinindianpatientsanobservationalstudy
AT hardeyogeshr opticnervesheathdiameterasamarkerforevaluationandprognosticationofintracranialpressureinindianpatientsanobservationalstudy
AT venkategowdapradeepm opticnervesheathdiameterasamarkerforevaluationandprognosticationofintracranialpressureinindianpatientsanobservationalstudy
AT maheshmuma opticnervesheathdiameterasamarkerforevaluationandprognosticationofintracranialpressureinindianpatientsanobservationalstudy