Cargando…

Semi-quantitative Multispectral Optoacoustic Tomography (MSOT) for volumetric PK imaging of gastric emptying

A common side effect of medication is gastrointestinal intolerance. Symptoms can include reduced appetite, diarrhea, constipation, GI inflammation, nausea and vomiting. Such effects often have a dramatic impact on compliance with a treatment regimen. Therefore, characterization of GI tolerance is an...

Descripción completa

Detalles Bibliográficos
Autores principales: Morscher, Stefan, Driessen, Wouter H.P., Claussen, Jing, Burton, Neal C.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4244636/
https://www.ncbi.nlm.nih.gov/pubmed/25431754
http://dx.doi.org/10.1016/j.pacs.2014.06.001
_version_ 1782346250078650368
author Morscher, Stefan
Driessen, Wouter H.P.
Claussen, Jing
Burton, Neal C.
author_facet Morscher, Stefan
Driessen, Wouter H.P.
Claussen, Jing
Burton, Neal C.
author_sort Morscher, Stefan
collection PubMed
description A common side effect of medication is gastrointestinal intolerance. Symptoms can include reduced appetite, diarrhea, constipation, GI inflammation, nausea and vomiting. Such effects often have a dramatic impact on compliance with a treatment regimen. Therefore, characterization of GI tolerance is an important step when establishing a novel therapeutic approach. In this study, Multispectral Optoacoustic Tomography (MSOT) is used to monitor gastrointestinal motility by in vivo whole body imaging in mice. MSOT combines high spatial and temporal resolution based on ultrasound detection with strong optical contrast in the near infrared. Animals were given Indocyanine Green (ICG) by oral gavage and imaged by MSOT to observe the fate of ICG in the gastrointestinal tract. Exponential decay of ICG signal was observed in the stomach in good correlation with ex vivo validation. We discuss how kinetic imaging in MSOT allows visualization of parameters unavailable to other imaging methods, both in 2D and 3D.
format Online
Article
Text
id pubmed-4244636
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-42446362014-11-27 Semi-quantitative Multispectral Optoacoustic Tomography (MSOT) for volumetric PK imaging of gastric emptying Morscher, Stefan Driessen, Wouter H.P. Claussen, Jing Burton, Neal C. Photoacoustics Research Article A common side effect of medication is gastrointestinal intolerance. Symptoms can include reduced appetite, diarrhea, constipation, GI inflammation, nausea and vomiting. Such effects often have a dramatic impact on compliance with a treatment regimen. Therefore, characterization of GI tolerance is an important step when establishing a novel therapeutic approach. In this study, Multispectral Optoacoustic Tomography (MSOT) is used to monitor gastrointestinal motility by in vivo whole body imaging in mice. MSOT combines high spatial and temporal resolution based on ultrasound detection with strong optical contrast in the near infrared. Animals were given Indocyanine Green (ICG) by oral gavage and imaged by MSOT to observe the fate of ICG in the gastrointestinal tract. Exponential decay of ICG signal was observed in the stomach in good correlation with ex vivo validation. We discuss how kinetic imaging in MSOT allows visualization of parameters unavailable to other imaging methods, both in 2D and 3D. Elsevier 2014-06-27 /pmc/articles/PMC4244636/ /pubmed/25431754 http://dx.doi.org/10.1016/j.pacs.2014.06.001 Text en © 2014 The Authors https://creativecommons.org/licenses/by/3.0/This work is licensed under a Creative Commons Attribution 3.0 Unported License (https://creativecommons.org/licenses/by/3.0/) .
spellingShingle Research Article
Morscher, Stefan
Driessen, Wouter H.P.
Claussen, Jing
Burton, Neal C.
Semi-quantitative Multispectral Optoacoustic Tomography (MSOT) for volumetric PK imaging of gastric emptying
title Semi-quantitative Multispectral Optoacoustic Tomography (MSOT) for volumetric PK imaging of gastric emptying
title_full Semi-quantitative Multispectral Optoacoustic Tomography (MSOT) for volumetric PK imaging of gastric emptying
title_fullStr Semi-quantitative Multispectral Optoacoustic Tomography (MSOT) for volumetric PK imaging of gastric emptying
title_full_unstemmed Semi-quantitative Multispectral Optoacoustic Tomography (MSOT) for volumetric PK imaging of gastric emptying
title_short Semi-quantitative Multispectral Optoacoustic Tomography (MSOT) for volumetric PK imaging of gastric emptying
title_sort semi-quantitative multispectral optoacoustic tomography (msot) for volumetric pk imaging of gastric emptying
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4244636/
https://www.ncbi.nlm.nih.gov/pubmed/25431754
http://dx.doi.org/10.1016/j.pacs.2014.06.001
work_keys_str_mv AT morscherstefan semiquantitativemultispectraloptoacoustictomographymsotforvolumetricpkimagingofgastricemptying
AT driessenwouterhp semiquantitativemultispectraloptoacoustictomographymsotforvolumetricpkimagingofgastricemptying
AT claussenjing semiquantitativemultispectraloptoacoustictomographymsotforvolumetricpkimagingofgastricemptying
AT burtonnealc semiquantitativemultispectraloptoacoustictomographymsotforvolumetricpkimagingofgastricemptying