Comparison of Different Magnetic Resonance Cholangiography Techniques in Living Liver Donors Including Gd-EOB-DTPA Enhanced T1-Weighted Sequences

OBJECTIVES: Preoperative evaluation of potential living liver donors (PLLDs) includes the assessment of the biliary anatomy to avoid postoperative complications. Aim of this study was to compare T2-weighted (T2w) and Gd-EOB-DTPA enhanced T1-weighted (T1w) magnetic resonance cholangiography (MRC) tec...

Descripción completa

Detalles Bibliográficos
Autores principales: Kinner, Sonja, Steinweg, Verena, Maderwald, Stefan, Radtke, Arnold, Sotiropoulos, Georgios, Forsting, Michael, Schroeder, Tobias
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4245231/
https://www.ncbi.nlm.nih.gov/pubmed/25426932
http://dx.doi.org/10.1371/journal.pone.0113882
_version_ 1782346337705000960
author Kinner, Sonja
Steinweg, Verena
Maderwald, Stefan
Radtke, Arnold
Sotiropoulos, Georgios
Forsting, Michael
Schroeder, Tobias
author_facet Kinner, Sonja
Steinweg, Verena
Maderwald, Stefan
Radtke, Arnold
Sotiropoulos, Georgios
Forsting, Michael
Schroeder, Tobias
author_sort Kinner, Sonja
collection PubMed
description OBJECTIVES: Preoperative evaluation of potential living liver donors (PLLDs) includes the assessment of the biliary anatomy to avoid postoperative complications. Aim of this study was to compare T2-weighted (T2w) and Gd-EOB-DTPA enhanced T1-weighted (T1w) magnetic resonance cholangiography (MRC) techniques in the evaluation of PLLDs. MATERIALS AND METHODS: 30 PLLDs underwent MRC on a 1.5 T Magnetom Avanto (Siemens, Erlangen, Germany) using (A) 2D T2w HASTE (Half Fourier Acquisition Single Shot Turbo Spin Echo) fat saturated (fs) in axial plane, (B) 2D T2w HASTE fs thick slices in coronal plane, (C) free breathing 3D T2w TSE (turbo spin echo) RESTORE (high-resolution navigator corrected) plus (D) maximum intensity projections (MIPs), (E) T2w SPACE (sampling perfection with application optimized contrasts using different flip angle evolutions) plus (F) MIPs and (G) T2w TSE BLADE as well as Gd-EOB-DTPA T1w images without (G) and with (H) inversion recovery. Contrast enhanced CT cholangiography served as reference imaging modality. Two independent reviewers evaluated the biliary tract anatomy on a 5-point scale subjectively and objectively. Data sets were compared using a Mann-Whitney-U-test. Kappa values were also calculated. RESULTS: Source images and maximum intensity projections of 3D T2w TSE sequences (RESTORE and SPACE) proved to be best for subjective and objective evaluation directly followed by 2D HASTE sequences. Interobserver variabilities were good to excellent (k = 0.622–0.804). CONCLUSIONS: 3D T2w sequences are essential for preoperative biliary tract evaluation in potential living liver donors. Furthermore, our results underline the value of different MRCP sequence types for the evaluation of the biliary anatomy in PLLDs including Gd-EOB-DTPA enhanced T1w MRC.
format Online
Article
Text
id pubmed-4245231
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-42452312014-12-05 Comparison of Different Magnetic Resonance Cholangiography Techniques in Living Liver Donors Including Gd-EOB-DTPA Enhanced T1-Weighted Sequences Kinner, Sonja Steinweg, Verena Maderwald, Stefan Radtke, Arnold Sotiropoulos, Georgios Forsting, Michael Schroeder, Tobias PLoS One Research Article OBJECTIVES: Preoperative evaluation of potential living liver donors (PLLDs) includes the assessment of the biliary anatomy to avoid postoperative complications. Aim of this study was to compare T2-weighted (T2w) and Gd-EOB-DTPA enhanced T1-weighted (T1w) magnetic resonance cholangiography (MRC) techniques in the evaluation of PLLDs. MATERIALS AND METHODS: 30 PLLDs underwent MRC on a 1.5 T Magnetom Avanto (Siemens, Erlangen, Germany) using (A) 2D T2w HASTE (Half Fourier Acquisition Single Shot Turbo Spin Echo) fat saturated (fs) in axial plane, (B) 2D T2w HASTE fs thick slices in coronal plane, (C) free breathing 3D T2w TSE (turbo spin echo) RESTORE (high-resolution navigator corrected) plus (D) maximum intensity projections (MIPs), (E) T2w SPACE (sampling perfection with application optimized contrasts using different flip angle evolutions) plus (F) MIPs and (G) T2w TSE BLADE as well as Gd-EOB-DTPA T1w images without (G) and with (H) inversion recovery. Contrast enhanced CT cholangiography served as reference imaging modality. Two independent reviewers evaluated the biliary tract anatomy on a 5-point scale subjectively and objectively. Data sets were compared using a Mann-Whitney-U-test. Kappa values were also calculated. RESULTS: Source images and maximum intensity projections of 3D T2w TSE sequences (RESTORE and SPACE) proved to be best for subjective and objective evaluation directly followed by 2D HASTE sequences. Interobserver variabilities were good to excellent (k = 0.622–0.804). CONCLUSIONS: 3D T2w sequences are essential for preoperative biliary tract evaluation in potential living liver donors. Furthermore, our results underline the value of different MRCP sequence types for the evaluation of the biliary anatomy in PLLDs including Gd-EOB-DTPA enhanced T1w MRC. Public Library of Science 2014-11-26 /pmc/articles/PMC4245231/ /pubmed/25426932 http://dx.doi.org/10.1371/journal.pone.0113882 Text en © 2014 Kinner et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited.
spellingShingle Research Article
Kinner, Sonja
Steinweg, Verena
Maderwald, Stefan
Radtke, Arnold
Sotiropoulos, Georgios
Forsting, Michael
Schroeder, Tobias
Comparison of Different Magnetic Resonance Cholangiography Techniques in Living Liver Donors Including Gd-EOB-DTPA Enhanced T1-Weighted Sequences
title Comparison of Different Magnetic Resonance Cholangiography Techniques in Living Liver Donors Including Gd-EOB-DTPA Enhanced T1-Weighted Sequences
title_full Comparison of Different Magnetic Resonance Cholangiography Techniques in Living Liver Donors Including Gd-EOB-DTPA Enhanced T1-Weighted Sequences
title_fullStr Comparison of Different Magnetic Resonance Cholangiography Techniques in Living Liver Donors Including Gd-EOB-DTPA Enhanced T1-Weighted Sequences
title_full_unstemmed Comparison of Different Magnetic Resonance Cholangiography Techniques in Living Liver Donors Including Gd-EOB-DTPA Enhanced T1-Weighted Sequences
title_short Comparison of Different Magnetic Resonance Cholangiography Techniques in Living Liver Donors Including Gd-EOB-DTPA Enhanced T1-Weighted Sequences
title_sort comparison of different magnetic resonance cholangiography techniques in living liver donors including gd-eob-dtpa enhanced t1-weighted sequences
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4245231/
https://www.ncbi.nlm.nih.gov/pubmed/25426932
http://dx.doi.org/10.1371/journal.pone.0113882
work_keys_str_mv AT kinnersonja comparisonofdifferentmagneticresonancecholangiographytechniquesinlivingliverdonorsincludinggdeobdtpaenhancedt1weightedsequences
AT steinwegverena comparisonofdifferentmagneticresonancecholangiographytechniquesinlivingliverdonorsincludinggdeobdtpaenhancedt1weightedsequences
AT maderwaldstefan comparisonofdifferentmagneticresonancecholangiographytechniquesinlivingliverdonorsincludinggdeobdtpaenhancedt1weightedsequences
AT radtkearnold comparisonofdifferentmagneticresonancecholangiographytechniquesinlivingliverdonorsincludinggdeobdtpaenhancedt1weightedsequences
AT sotiropoulosgeorgios comparisonofdifferentmagneticresonancecholangiographytechniquesinlivingliverdonorsincludinggdeobdtpaenhancedt1weightedsequences
AT forstingmichael comparisonofdifferentmagneticresonancecholangiographytechniquesinlivingliverdonorsincludinggdeobdtpaenhancedt1weightedsequences
AT schroedertobias comparisonofdifferentmagneticresonancecholangiographytechniquesinlivingliverdonorsincludinggdeobdtpaenhancedt1weightedsequences