Cargando…

Effect of different ferrule designs on the fracture resistance and failure pattern of endodontically treated teeth restored with fiber posts and allceramic crowns

OBJECTIVE: This study investigated the effect of different ferrule heights on endodontically treated premolars. MATERIALS AND METHODS: Fifty sound mandibular first premolars were endodontically treated and then restored with 7-mm fiber post (FRC Postec Plus #1 Ivoclar-Vivadent) luted with self-polym...

Descripción completa

Detalles Bibliográficos
Autores principales: SHERFUDHIN, Haneef, HOBEICH, Joseph, CARVALHO, Carlos Augusto, N. ABOUSHELIB, Moustafa, SADIG, Walid, SALAMEH, Ziad
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Faculdade de Odontologia de Bauru da Universidade de São Paulo 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4245860/
https://www.ncbi.nlm.nih.gov/pubmed/21437466
http://dx.doi.org/10.1590/S1678-77572011000100007
_version_ 1782346437730762752
author SHERFUDHIN, Haneef
HOBEICH, Joseph
CARVALHO, Carlos Augusto
N. ABOUSHELIB, Moustafa
SADIG, Walid
SALAMEH, Ziad
author_facet SHERFUDHIN, Haneef
HOBEICH, Joseph
CARVALHO, Carlos Augusto
N. ABOUSHELIB, Moustafa
SADIG, Walid
SALAMEH, Ziad
author_sort SHERFUDHIN, Haneef
collection PubMed
description OBJECTIVE: This study investigated the effect of different ferrule heights on endodontically treated premolars. MATERIALS AND METHODS: Fifty sound mandibular first premolars were endodontically treated and then restored with 7-mm fiber post (FRC Postec Plus #1 Ivoclar-Vivadent) luted with self-polymerized resin cement (Multilink, Ivoclar Vivadent) while the coronal section was restored with hybrid composite core build-up material (Tetric Ceram, Ivoclar-Vivadent), which received all-ceramic crown. Different ferrule heights were investigated: 1-mm circumferential ferrule without post and core (group 1 used as control), a circumferential 1-mm ferrule (group 2), non-uniform ferrule 2-mm buccally and 1-mm lingually (group 3), non-uniform ferrule 3-mm buccally and 2-mm lingually (group 4), and finally no ferrule preparation (group 5). The fracture load and failure pattern of the tested groups were investigated by applying axial load to the ceramic crowns (n=10). Data were analyzed statistically by one-way ANOVA and Tukey’s post-hoc test was used for pair-wise comparisons (α=0.05). RESULTS: There were no significant differences among the failure load of all tested groups (P<0.780). The control group had the lowest fracture resistance (891.43±202.22 N) and the highest catastrophic failure rate (P<0.05). Compared to the control group, the use of fiber post reduced the percentage of catastrophic failure while increasing the ferrule height did not influence the fracture resistance of the restored specimens. CONCLUSIONS: Within the limitations of this study, increasing the ferrule length did not influence the fracture resistance of endodontically treated teeth restored with glass ceramic crowns. Insertion of a fiber post could reduce the percentage of catastrophic failure of these restorations under function.
format Online
Article
Text
id pubmed-4245860
institution National Center for Biotechnology Information
language English
publishDate 2011
publisher Faculdade de Odontologia de Bauru da Universidade de São Paulo
record_format MEDLINE/PubMed
spelling pubmed-42458602014-11-28 Effect of different ferrule designs on the fracture resistance and failure pattern of endodontically treated teeth restored with fiber posts and allceramic crowns SHERFUDHIN, Haneef HOBEICH, Joseph CARVALHO, Carlos Augusto N. ABOUSHELIB, Moustafa SADIG, Walid SALAMEH, Ziad J Appl Oral Sci Original Articles OBJECTIVE: This study investigated the effect of different ferrule heights on endodontically treated premolars. MATERIALS AND METHODS: Fifty sound mandibular first premolars were endodontically treated and then restored with 7-mm fiber post (FRC Postec Plus #1 Ivoclar-Vivadent) luted with self-polymerized resin cement (Multilink, Ivoclar Vivadent) while the coronal section was restored with hybrid composite core build-up material (Tetric Ceram, Ivoclar-Vivadent), which received all-ceramic crown. Different ferrule heights were investigated: 1-mm circumferential ferrule without post and core (group 1 used as control), a circumferential 1-mm ferrule (group 2), non-uniform ferrule 2-mm buccally and 1-mm lingually (group 3), non-uniform ferrule 3-mm buccally and 2-mm lingually (group 4), and finally no ferrule preparation (group 5). The fracture load and failure pattern of the tested groups were investigated by applying axial load to the ceramic crowns (n=10). Data were analyzed statistically by one-way ANOVA and Tukey’s post-hoc test was used for pair-wise comparisons (α=0.05). RESULTS: There were no significant differences among the failure load of all tested groups (P<0.780). The control group had the lowest fracture resistance (891.43±202.22 N) and the highest catastrophic failure rate (P<0.05). Compared to the control group, the use of fiber post reduced the percentage of catastrophic failure while increasing the ferrule height did not influence the fracture resistance of the restored specimens. CONCLUSIONS: Within the limitations of this study, increasing the ferrule length did not influence the fracture resistance of endodontically treated teeth restored with glass ceramic crowns. Insertion of a fiber post could reduce the percentage of catastrophic failure of these restorations under function. Faculdade de Odontologia de Bauru da Universidade de São Paulo 2011 /pmc/articles/PMC4245860/ /pubmed/21437466 http://dx.doi.org/10.1590/S1678-77572011000100007 Text en http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Articles
SHERFUDHIN, Haneef
HOBEICH, Joseph
CARVALHO, Carlos Augusto
N. ABOUSHELIB, Moustafa
SADIG, Walid
SALAMEH, Ziad
Effect of different ferrule designs on the fracture resistance and failure pattern of endodontically treated teeth restored with fiber posts and allceramic crowns
title Effect of different ferrule designs on the fracture resistance and failure pattern of endodontically treated teeth restored with fiber posts and allceramic crowns
title_full Effect of different ferrule designs on the fracture resistance and failure pattern of endodontically treated teeth restored with fiber posts and allceramic crowns
title_fullStr Effect of different ferrule designs on the fracture resistance and failure pattern of endodontically treated teeth restored with fiber posts and allceramic crowns
title_full_unstemmed Effect of different ferrule designs on the fracture resistance and failure pattern of endodontically treated teeth restored with fiber posts and allceramic crowns
title_short Effect of different ferrule designs on the fracture resistance and failure pattern of endodontically treated teeth restored with fiber posts and allceramic crowns
title_sort effect of different ferrule designs on the fracture resistance and failure pattern of endodontically treated teeth restored with fiber posts and allceramic crowns
topic Original Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4245860/
https://www.ncbi.nlm.nih.gov/pubmed/21437466
http://dx.doi.org/10.1590/S1678-77572011000100007
work_keys_str_mv AT sherfudhinhaneef effectofdifferentferruledesignsonthefractureresistanceandfailurepatternofendodonticallytreatedteethrestoredwithfiberpostsandallceramiccrowns
AT hobeichjoseph effectofdifferentferruledesignsonthefractureresistanceandfailurepatternofendodonticallytreatedteethrestoredwithfiberpostsandallceramiccrowns
AT carvalhocarlosaugusto effectofdifferentferruledesignsonthefractureresistanceandfailurepatternofendodonticallytreatedteethrestoredwithfiberpostsandallceramiccrowns
AT naboushelibmoustafa effectofdifferentferruledesignsonthefractureresistanceandfailurepatternofendodonticallytreatedteethrestoredwithfiberpostsandallceramiccrowns
AT sadigwalid effectofdifferentferruledesignsonthefractureresistanceandfailurepatternofendodonticallytreatedteethrestoredwithfiberpostsandallceramiccrowns
AT salamehziad effectofdifferentferruledesignsonthefractureresistanceandfailurepatternofendodonticallytreatedteethrestoredwithfiberpostsandallceramiccrowns