Cargando…

Three-dimensional balanced steady state free precession myocardial perfusion cardiovascular magnetic resonance at 3T using dual-source parallel RF transmission: initial experience

BACKGROUND: The purpose of this study was to establish the feasibility of three-dimensional (3D) balanced steady-state-free-precession (bSSFP) myocardial perfusion cardiovascular magnetic resonance (CMR) at 3T using local RF shimming with dual-source RF transmission, and to compare it with spoiled g...

Descripción completa

Detalles Bibliográficos
Autores principales: Jogiya, Roy, Schuster, Andreas, Zaman, Arshad, Motwani, Manish, Kouwenhoven, Marc, Nagel, Eike, Kozerke, Sebastian, Plein, Sven
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4247198/
https://www.ncbi.nlm.nih.gov/pubmed/25429993
http://dx.doi.org/10.1186/s12968-014-0090-0
_version_ 1782346601242558464
author Jogiya, Roy
Schuster, Andreas
Zaman, Arshad
Motwani, Manish
Kouwenhoven, Marc
Nagel, Eike
Kozerke, Sebastian
Plein, Sven
author_facet Jogiya, Roy
Schuster, Andreas
Zaman, Arshad
Motwani, Manish
Kouwenhoven, Marc
Nagel, Eike
Kozerke, Sebastian
Plein, Sven
author_sort Jogiya, Roy
collection PubMed
description BACKGROUND: The purpose of this study was to establish the feasibility of three-dimensional (3D) balanced steady-state-free-precession (bSSFP) myocardial perfusion cardiovascular magnetic resonance (CMR) at 3T using local RF shimming with dual-source RF transmission, and to compare it with spoiled gradient echo (TGRE) acquisition. METHODS: Dynamic contrast-enhanced 3D bSSFP perfusion imaging was performed on a 3T MRI scanner equipped with dual-source RF transmission technology. Images were reconstructed using k-space and time broad-use linear acquisition speed-up technique (k-t BLAST) and compartment based principle component analysis (k-t PCA). RESULTS: In phantoms and volunteers, local RF shimming with dual source RF transmission significantly improved B1 field homogeneity compared with single source transmission (P = 0.01). 3D bSSFP showed improved signal-to-noise, contrast-to-noise and signal homogeneity compared with 3D TGRE (29.8 vs 26.9, P = 0.045; 23.2 vs 21.6, P = 0.049; 14.9% vs 12.4%, p = 0.002, respectively). Image quality was similar between bSSFP and TGRE but there were more dark rim artefacts with bSSFP. k-t PCA reconstruction reduced artefacts for both sequences compared with k-t BLAST. In a subset of five patients, both methods correctly identified those with coronary artery disease. CONCLUSION: Three-dimensional bSSFP myocardial perfusion CMR using local RF shimming with dual source parallel RF transmission at 3T is feasible and improves signal characteristics compared with TGRE. Image artefact remains an important limitation of bSSFP imaging at 3T but can be reduced with k-t PCA. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1186/s12968-014-0090-0) contains supplementary material, which is available to authorized users.
format Online
Article
Text
id pubmed-4247198
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-42471982014-11-29 Three-dimensional balanced steady state free precession myocardial perfusion cardiovascular magnetic resonance at 3T using dual-source parallel RF transmission: initial experience Jogiya, Roy Schuster, Andreas Zaman, Arshad Motwani, Manish Kouwenhoven, Marc Nagel, Eike Kozerke, Sebastian Plein, Sven J Cardiovasc Magn Reson Technical Notes BACKGROUND: The purpose of this study was to establish the feasibility of three-dimensional (3D) balanced steady-state-free-precession (bSSFP) myocardial perfusion cardiovascular magnetic resonance (CMR) at 3T using local RF shimming with dual-source RF transmission, and to compare it with spoiled gradient echo (TGRE) acquisition. METHODS: Dynamic contrast-enhanced 3D bSSFP perfusion imaging was performed on a 3T MRI scanner equipped with dual-source RF transmission technology. Images were reconstructed using k-space and time broad-use linear acquisition speed-up technique (k-t BLAST) and compartment based principle component analysis (k-t PCA). RESULTS: In phantoms and volunteers, local RF shimming with dual source RF transmission significantly improved B1 field homogeneity compared with single source transmission (P = 0.01). 3D bSSFP showed improved signal-to-noise, contrast-to-noise and signal homogeneity compared with 3D TGRE (29.8 vs 26.9, P = 0.045; 23.2 vs 21.6, P = 0.049; 14.9% vs 12.4%, p = 0.002, respectively). Image quality was similar between bSSFP and TGRE but there were more dark rim artefacts with bSSFP. k-t PCA reconstruction reduced artefacts for both sequences compared with k-t BLAST. In a subset of five patients, both methods correctly identified those with coronary artery disease. CONCLUSION: Three-dimensional bSSFP myocardial perfusion CMR using local RF shimming with dual source parallel RF transmission at 3T is feasible and improves signal characteristics compared with TGRE. Image artefact remains an important limitation of bSSFP imaging at 3T but can be reduced with k-t PCA. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1186/s12968-014-0090-0) contains supplementary material, which is available to authorized users. BioMed Central 2014-11-28 /pmc/articles/PMC4247198/ /pubmed/25429993 http://dx.doi.org/10.1186/s12968-014-0090-0 Text en © Jogiya et al.; licensee BioMed Central Ltd. 2014 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Technical Notes
Jogiya, Roy
Schuster, Andreas
Zaman, Arshad
Motwani, Manish
Kouwenhoven, Marc
Nagel, Eike
Kozerke, Sebastian
Plein, Sven
Three-dimensional balanced steady state free precession myocardial perfusion cardiovascular magnetic resonance at 3T using dual-source parallel RF transmission: initial experience
title Three-dimensional balanced steady state free precession myocardial perfusion cardiovascular magnetic resonance at 3T using dual-source parallel RF transmission: initial experience
title_full Three-dimensional balanced steady state free precession myocardial perfusion cardiovascular magnetic resonance at 3T using dual-source parallel RF transmission: initial experience
title_fullStr Three-dimensional balanced steady state free precession myocardial perfusion cardiovascular magnetic resonance at 3T using dual-source parallel RF transmission: initial experience
title_full_unstemmed Three-dimensional balanced steady state free precession myocardial perfusion cardiovascular magnetic resonance at 3T using dual-source parallel RF transmission: initial experience
title_short Three-dimensional balanced steady state free precession myocardial perfusion cardiovascular magnetic resonance at 3T using dual-source parallel RF transmission: initial experience
title_sort three-dimensional balanced steady state free precession myocardial perfusion cardiovascular magnetic resonance at 3t using dual-source parallel rf transmission: initial experience
topic Technical Notes
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4247198/
https://www.ncbi.nlm.nih.gov/pubmed/25429993
http://dx.doi.org/10.1186/s12968-014-0090-0
work_keys_str_mv AT jogiyaroy threedimensionalbalancedsteadystatefreeprecessionmyocardialperfusioncardiovascularmagneticresonanceat3tusingdualsourceparallelrftransmissioninitialexperience
AT schusterandreas threedimensionalbalancedsteadystatefreeprecessionmyocardialperfusioncardiovascularmagneticresonanceat3tusingdualsourceparallelrftransmissioninitialexperience
AT zamanarshad threedimensionalbalancedsteadystatefreeprecessionmyocardialperfusioncardiovascularmagneticresonanceat3tusingdualsourceparallelrftransmissioninitialexperience
AT motwanimanish threedimensionalbalancedsteadystatefreeprecessionmyocardialperfusioncardiovascularmagneticresonanceat3tusingdualsourceparallelrftransmissioninitialexperience
AT kouwenhovenmarc threedimensionalbalancedsteadystatefreeprecessionmyocardialperfusioncardiovascularmagneticresonanceat3tusingdualsourceparallelrftransmissioninitialexperience
AT nageleike threedimensionalbalancedsteadystatefreeprecessionmyocardialperfusioncardiovascularmagneticresonanceat3tusingdualsourceparallelrftransmissioninitialexperience
AT kozerkesebastian threedimensionalbalancedsteadystatefreeprecessionmyocardialperfusioncardiovascularmagneticresonanceat3tusingdualsourceparallelrftransmissioninitialexperience
AT pleinsven threedimensionalbalancedsteadystatefreeprecessionmyocardialperfusioncardiovascularmagneticresonanceat3tusingdualsourceparallelrftransmissioninitialexperience