Cargando…

Comparison of canine retraction by in vivo method using four brands of elastomeric power chain

OBJECTIVE: To investigate the amount of space closure by movement of canines into the extraction spaces using four brands of elastomeric power chains (EPCs) by intraoral application with pre-adjusted appliance for 6 weeks. MATERIALS AND METHODS: The sample size calculation was based on the studies o...

Descripción completa

Detalles Bibliográficos
Autores principales: Kanuru, Ravi Krishna, Azaneen, Mustafa, Narayana, Veera, Kolasani, Balaram, Indukuri, Ravikishore Reddy, Babu, P Firoz
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4247548/
https://www.ncbi.nlm.nih.gov/pubmed/25452925
http://dx.doi.org/10.4103/2231-0762.144586
_version_ 1782346657534312448
author Kanuru, Ravi Krishna
Azaneen, Mustafa
Narayana, Veera
Kolasani, Balaram
Indukuri, Ravikishore Reddy
Babu, P Firoz
author_facet Kanuru, Ravi Krishna
Azaneen, Mustafa
Narayana, Veera
Kolasani, Balaram
Indukuri, Ravikishore Reddy
Babu, P Firoz
author_sort Kanuru, Ravi Krishna
collection PubMed
description OBJECTIVE: To investigate the amount of space closure by movement of canines into the extraction spaces using four brands of elastomeric power chains (EPCs) by intraoral application with pre-adjusted appliance for 6 weeks. MATERIALS AND METHODS: The sample size calculation was based on the studies of Boester and Johnston and also with repeated measures analysis of variance (ANOVA) continuous data for force degradation, standard deviation of 24.9 g, and also from a pilot study, which totaled to around 17 patients with a mean age of 20 ± 2 years and receiving fixed orthodontic treatment that required retraction of canines into the premolar extraction spaces in all four dental arch quadrants. Four brands of EPCs, namely the Ormco, 3M Unitek, Rocky Mountain, and Highland, which were closed-link with five loops delivering less than or equal to 250 g were used. The rates of canine retraction were measured between the attachment points on the canine bracket hook and first molar hook using a Mitutoyo Digital Vernier Caliper at the time of first application, after 3 weeks of use, and at the end of 6 weeks of use, and were subjected to statistical calculations. RESULTS: The distances recorded from canine retraction were similar with slight differences noticed in the four brands of EPCs. However, no statistically significant difference was observed in relation to the EPCs. CONCLUSION: Although all brands of the EPCs produced space closure of canines, it was observed that not much of a significant difference existed among the products tested.
format Online
Article
Text
id pubmed-4247548
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-42475482014-12-01 Comparison of canine retraction by in vivo method using four brands of elastomeric power chain Kanuru, Ravi Krishna Azaneen, Mustafa Narayana, Veera Kolasani, Balaram Indukuri, Ravikishore Reddy Babu, P Firoz J Int Soc Prev Community Dent Original Article OBJECTIVE: To investigate the amount of space closure by movement of canines into the extraction spaces using four brands of elastomeric power chains (EPCs) by intraoral application with pre-adjusted appliance for 6 weeks. MATERIALS AND METHODS: The sample size calculation was based on the studies of Boester and Johnston and also with repeated measures analysis of variance (ANOVA) continuous data for force degradation, standard deviation of 24.9 g, and also from a pilot study, which totaled to around 17 patients with a mean age of 20 ± 2 years and receiving fixed orthodontic treatment that required retraction of canines into the premolar extraction spaces in all four dental arch quadrants. Four brands of EPCs, namely the Ormco, 3M Unitek, Rocky Mountain, and Highland, which were closed-link with five loops delivering less than or equal to 250 g were used. The rates of canine retraction were measured between the attachment points on the canine bracket hook and first molar hook using a Mitutoyo Digital Vernier Caliper at the time of first application, after 3 weeks of use, and at the end of 6 weeks of use, and were subjected to statistical calculations. RESULTS: The distances recorded from canine retraction were similar with slight differences noticed in the four brands of EPCs. However, no statistically significant difference was observed in relation to the EPCs. CONCLUSION: Although all brands of the EPCs produced space closure of canines, it was observed that not much of a significant difference existed among the products tested. Medknow Publications & Media Pvt Ltd 2014-11 /pmc/articles/PMC4247548/ /pubmed/25452925 http://dx.doi.org/10.4103/2231-0762.144586 Text en Copyright: © Journal of International Society of Preventive and Community Dentistry http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Kanuru, Ravi Krishna
Azaneen, Mustafa
Narayana, Veera
Kolasani, Balaram
Indukuri, Ravikishore Reddy
Babu, P Firoz
Comparison of canine retraction by in vivo method using four brands of elastomeric power chain
title Comparison of canine retraction by in vivo method using four brands of elastomeric power chain
title_full Comparison of canine retraction by in vivo method using four brands of elastomeric power chain
title_fullStr Comparison of canine retraction by in vivo method using four brands of elastomeric power chain
title_full_unstemmed Comparison of canine retraction by in vivo method using four brands of elastomeric power chain
title_short Comparison of canine retraction by in vivo method using four brands of elastomeric power chain
title_sort comparison of canine retraction by in vivo method using four brands of elastomeric power chain
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4247548/
https://www.ncbi.nlm.nih.gov/pubmed/25452925
http://dx.doi.org/10.4103/2231-0762.144586
work_keys_str_mv AT kanururavikrishna comparisonofcanineretractionbyinvivomethodusingfourbrandsofelastomericpowerchain
AT azaneenmustafa comparisonofcanineretractionbyinvivomethodusingfourbrandsofelastomericpowerchain
AT narayanaveera comparisonofcanineretractionbyinvivomethodusingfourbrandsofelastomericpowerchain
AT kolasanibalaram comparisonofcanineretractionbyinvivomethodusingfourbrandsofelastomericpowerchain
AT indukuriravikishorereddy comparisonofcanineretractionbyinvivomethodusingfourbrandsofelastomericpowerchain
AT babupfiroz comparisonofcanineretractionbyinvivomethodusingfourbrandsofelastomericpowerchain