Cargando…

Association of physical function with predialysis blood pressure in patients on hemodialysis

BACKGROUND: New information from various clinical settings suggests that tight blood pressure control may not reduce mortality and may be associated with more side effects. METHODS: We performed cross-sectional multivariable ordered logistic regression to examine the association between predialysis...

Descripción completa

Detalles Bibliográficos
Autores principales: Abreo, Adrian P, Glidden, David, Painter, Patricia, Lea, Janice, Herzog, Charles A, Kutner, Nancy G, Johansen, Kirsten L
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4247716/
https://www.ncbi.nlm.nih.gov/pubmed/25399253
http://dx.doi.org/10.1186/1471-2369-15-177
Descripción
Sumario:BACKGROUND: New information from various clinical settings suggests that tight blood pressure control may not reduce mortality and may be associated with more side effects. METHODS: We performed cross-sectional multivariable ordered logistic regression to examine the association between predialysis blood pressure and the short physical performance battery (SPPB) in a cohort of 749 prevalent hemodialysis patients in the San Francisco and Atlanta areas recruited from July 2009 to August 2011 to study the relationship between systolic blood pressure and objective measures of physical function. Mean blood pressure for three hemodialysis sessions was analyzed in the following categories: <110 mmHg, 110-129 mmHg (reference), 130-159 mmHg, and ≥160 mmHg. SPPB includes three components: timed repeated chair stands, timed 15-ft walk, and balance tests. SPPB was categorized into ordinal groups (≤6, 7-9, 10-12) based on prior literature. RESULTS: Patients with blood pressure 130-159 mmHg had lower odds (OR 0.57, 95% CI 0.35-0.93) of scoring in a lower SPPB category than those whose blood pressure was between 110 and 129 mmHg, while those with blood pressure ≥160 mmHg had 0.56 times odds (95% CI 0.33-0.94) of scoring in a lower category when compared with blood pressure 110-129 mmHg. When individual components were examined, blood pressure was significantly associated with chair stand (130-159 mmHg: OR 0.59, 95% CI 0.38-0.92) and gait speed (≥160 mmHg: OR 0.59, 95% CI 0.35-0.98). Blood pressure ≥160 mmHg was not associated with substantially higher SPPB score compared with 130-159 mmHg. CONCLUSIONS: Patients with systolic blood pressure at or above 130 mmHg had better physical performance than patients with lower blood pressure in the normotensive range. The risk-benefit tradeoff of aggressive blood pressure control, particularly in low-functioning patients, should be reexamined.